CLM Node Connection Loss
OPERATING INSTRUCTIONS

Contents


1   Alarm Description

The alarm is raised by the middleware Cluster Membership (CLM) service.

Table 1    CLM Node Connection Loss Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Failure of communication with the reported node.

A node has lost contact with the remaining cluster members.

Faulty physical Ethernet device.

Physical Ethernet interface.

The capacity or redundancy of the cluster is reduced.

The operating system and middleware layer are incorrectly configured.

Incorrect High Availability (HA) configuration for the cluster.

2   Procedure

2.1   2.1 Handle Alarm CLM Node Connection Loss

Prerequisites

Steps

  1. Was the alarm raised during initial installation or upgrade?
    • Yes: Contact the deployment organization. Proceed with Step 5.
    • No: Continue with the next step.
  2. Is any LOTC Ethernet Bonding alarm raised?
    • Yes: Clear the LOTC Ethernet Bonding alarm. Further actions are outside the scope of this instruction. Proceed with Step 5.
    • No: Continue with the next step.
  3. Perform data collection, refer to Data Collection Guideline.
  4. Consult the next level of maintenance support for an analysis of the root cause to the change in cluster state. Further actions are outside the scope of this instruction.
  5. Job is completed.