1 Alarm Description
This is an alarm of severity MINOR.
This alarm is issued when ECM detects a failure that it is unable to recover from.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
ECM detected a failure that it is unable to recover from. |
|
Internal cluster network |
The ECM process is shut down immediately. The ECM process is automatically restarted by the SS7 CAF AMF process. If the alarm is raised more than 5 times in 5 minutes or is persistent for 5 minutes, follow the procedure in Section 2. |
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
1586561538 |
|
Managed Object Class |
Not Applicable |
|
Source |
3GPPSystemComponents.Name=<*>,Ecm.Name=<*>,Host.Address=<*> |
|
Specific Problem |
ECM Goes Down |
|
Perceived Severity |
SEVERITY_MINOR |
2 Procedure
2.1 Handle Alarm ECM Goes Down
Prerequisites
- No documents are referenced.
- No tools are required.
- The following condition must apply:
- The alarm is raised multiple times.
Steps
- Collect the ss7trace.log located in /opt/sign/log.
Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file ecm.log and active.om.cim and all the files with the extension *.cnf.
- Contact next level of support and provide the files collected in Step 1.