1 Alarm Description
This is an alarm of severity MINOR.
The alarm is issued when an ECM has taken the active role.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
1586561542 |
|
Managed Object Class |
Not Applicable |
|
Source |
3GPPSystemComponents.Name=<*>,Ecm.Name=<*>,Host.Address=<*> |
|
Specific Problem |
SS7 CAF ECM Goes Active |
|
Perceived Severity |
SEVERITY_MINOR |
2 Procedure
2.1 Handle Alarm SS7 CAF ECM Goes Active
Prerequisites
- No documents are referenced.
- No tools are required.
- The following condition must apply:
- The alarm is raised multiple times or is persistent.
Steps
- Check other alarms from the cluster concerning the internal cluster network status.
- Collect the ecm.log and ss7trace.log located in /opt/sign/log.
Also collect the current configuration which is located in the folder /opt/sign/etc. Collect the file active.om.cim and all the files with the extension *.cnf.
- Contact next level of support and provide the files collected in Step 2.

Contents