1 Alarm Description
The alarm is raised by the middleware Model Delivery Function (MDF) service.
The alarm is raised when the MDF attempts to deliver a pending model to a model consumer through a callback, which returns a model error. The model remains in a pending state in a First In, First Out (FIFO) buffer. When the error occurs, the MDF logs the available information to the Service Availability Forum (SAF) system log.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The delivered model is defect. |
A model delivered as part of the software package is incorrectly designed by the producer of the package. |
The model is defect. |
Model |
The function related to the model is degraded. |
|
The consumer of the model is defect. |
A model-driven component, the "model consumer", cannot receive a correctly designed model. |
The model consumer is defect. |
Model consumer |
- Note:
- The alarm can appear as a result of an initial installation or a software upgrade.
2 Procedure
2.1 Handle Alarm COM SA, MDF Detected Model Error
Prerequisites
- This instruction references the following document:
- No tools are required.
- The following conditions must apply:
- The alarm is raised.
Steps
- Was the alarm raised during initial installation or upgrade?
Yes: Contact the deployment organization. Proceed with Step 5.
No: Continue with the next step.
- Perform a health check, refer to Health Check documentation available in the library.
- Perform data collection, refer to Data Collection Guideline.
- Consult the next level of maintenance support. Further actions are outside the scope of this instruction.
- Job is completed.