vMRF Network Impact Report
Virtual Multimedia Resource Function

Contents

1Introduction

2

General Impact
2.1General Impact for vMRF 1.1
2.2General Impact for vMRF 1.2
2.3General Impact for vMRF 1.3
2.4General Impact for vMRF 1.4
2.5General Impact for vMRF 1.5.0
2.6General Impact for vMRF 1.6.0
2.7Other Network Elements

3

Interfaces
3.1Interfaces in vMRF 1.1
3.2Interfaces in vMRF 1.2
3.3Interfaces in vMRF 1.3
3.4Interfaces in vMRF 1.4
3.5Interfaces in vMRF 1.5.0
3.6Interfaces in vMRF 1.6.0

4

Summary of Impacts per Feature

5

Impact on vMRF Features
5.1Impact on vMRF Features from vMRF 1.0 to vMRF 1.1
5.2Impact on vMRF Features from vMRF 1.1 to vMRF 1.2
5.3Impact on vMRF Features from vMRF 1.2 to vMRF 1.3
5.4Impact on vMRF Features from vMRF 1.3 to vMRF 1.4
5.5Impact on vMRF Features from vMRF 1.4 to vMRF 1.5.0
5.6Impact on vMRF Features from vMRF 1.5.0 to vMRF 1.6.0

1   Introduction

The Network Impact Report (NIR) describes how the current release of Virtual Multimedia Resource Function (vMRF) with new and changed features affects the previous release of vMRF and the operator's overall network, including all affected products and functions.

The purpose of this document is to provide sufficient information at an early stage to Ericsson system operators to help them plan the introduction of new products and upgrades to their networks.

This document is a living document and is subject to change during the development of the new release. Therefore, part of the information may be incomplete or unavailable until General Availability (GA) of the new vMRF release.

2   General Impact

This section describes the general impact for the various vMRF releases.

2.1   General Impact for vMRF 1.1

This section describes the general impact for the release.

2.1.1   Backward Compatibility

The enhanced functionality is backward compatible.

2.1.2   Capacity and Performance

Hyperthreading support has been introduced. When hyperthreading is in use, vMRF VMs are deployed by allocating two vCPUs per each physical CPU core. The use of hyperthreading increases the capacity of a single physical CPU core up to 20%. It is recommended to use hyperthreading, in which case only even VM flavor sizes are supported.

2.1.3   Operation

The following port number changes are introduced due to alignment with other IMS nodes:

2.2   General Impact for vMRF 1.2

This section describes the general impact for the release.

2.2.1   Backward Compatibility

Signaling subnet stacks created in previous releases are not upgrade compatible. vMRF configuration can be imported from previous releases.

2.2.2   Capacity and Performance

No impact.

2.2.3   Operation

The release includes parameter name changes in HOT and example environment files included in the software delivery package. Due to this, the example_environment.yaml from previous vMRF releases cannot be used when creating subnets. Before deployment, the old vMRF configuration must be backed up to a cluster-external storage, and the old vMRF stack and signaling subnet stack must be deleted. The example_environment.yaml file included in the software delivery package must be prepared with site-specific data, and vMRF must be deployed as described in the relevant manual deployment guides. After deployment, the previously exported configuration can be imported.

The following parameter changes are introduced:

The following new features are introduced:

2.3   General Impact for vMRF 1.3

This section describes the general impact for therelease.

2.3.1   Backward Compatibility

The enhanced functionality is backward compatible.

2.3.2   Capacity and Performance

No impact.

2.3.3   Operation

The following new features are introduced:

The following enhanced features are introduced:

2.4   General Impact for vMRF 1.4

This section describes the general impact for the release.

The following new features are introduced:

2.4.1   Backward Compatibility

The enhanced functionality is backward compatible.

2.4.2   Capacity and Performance

No impact.

2.4.3   Operation

A separate batch of HOT and example environment yaml files are included in the software delivery package for deployment with or without DHCP server configuration on OpenStack.

2.5   General Impact for vMRF 1.5.0

This section describes the general impact for the release.

2.5.1   Backward Compatibility

The enhanced functionality is backward compatible.

2.5.2   Capacity and Performance

The minimum VM storage disk space is increased to 6 GB.

2.5.3   Operation

Deployment on VMware vSphere is supported.

2.6   General Impact for vMRF 1.6.0

This section describes the general impact for the release.

2.6.1   Backward Compatibility

The enhanced functionality is backward compatible.

2.6.2   Capacity and Performance

Maximum number of PM files has been increased from 250 to 500.

2.6.3   Operation

The following changes are introduced:

2.7   Other Network Elements

2.7.1   Other Network Elements in vMRF 1.1

2.7.1.1   General

The lowest interoperable releases are described in Table 1.

Table 1    Lowest Interoperable Releases

MTAS

15B

vMTAS

16A

OSS-RC

17B

2.7.1.1.1   Multimedia Telephony Application Server (MTAS)

vMRF 1.1 is compatible with the following MTAS releases: 4.1, 4.2, 4.3, and 4.4.

2.7.1.1.2   Virtual Multimedia Telephony Application Server (vMTAS)

vMRF 1.1 is compatible with the following vMTAS release: 16A.

2.7.1.1.3   OSS-RC

vMRF 1.1 is compatible with the following OSS-RC release: 17B.

2.7.2   Other Network Elements in vMRF 1.2

2.7.2.1   General

The lowest interoperable releases are described in Table 2.

Table 2    Lowest Interoperable Releases

MTAS

16A

vMTAS

16A

OSS-RC

17B

2.7.2.1.1   Multimedia Telephony Application Server (MTAS)

vMRF 1.2 is compatible with the following MTAS releases: 4.0, 4.1, 4.2, 4.3, 4.4, 4.5, and 4.6.

2.7.2.1.2   Virtual Multimedia Telephony Application Server (vMTAS)

vMRF 1.2 is compatible with the following vMTAS releases: 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6.

2.7.2.1.3   OSS-RC

vMRF 1.2 is compatible with the following OSS-RC releases: 17B, 18A.

2.7.3   Other Network Elements in vMRF 1.3

2.7.3.1   General

The lowest interoperable releases are described in Table 3.

Table 3    Lowest Interoperable Releases

MTAS

16A

vMTAS

16A

OSS-RC

17B

ENM

17B

NeLS

1

2.7.3.1.1   Multimedia Telephony Application Server (MTAS)

vMRF 1.3 is compatible with the following MTAS releases: 4.0, 4.1, 4.2, 4.4, 4.5, and 4.6.

2.7.3.1.2   Virtual Multimedia Telephony Application Server (vMTAS)

vMRF 1.3 is compatible with the following vMTAS releases: 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6.

2.7.3.1.3   OSS-RC

vMRF 1.3 is compatible with the following OSS-RC releases: 17B, 18A.

Full functionality support for vMRF 1.3 is provided by the following OSS-RC release: 18A

2.7.3.1.4   Ericsson Network Manager (ENM)

vMRF 1.3 is compatible with the following ENM release: 17B

Full functionality support for vMRF 1.3 is provided by the following ENM release: 18A.

2.7.3.1.5   Network License Server (NeLS)

vMRF 1.3 is compatible with the following NeLS release: 1.

2.7.4   Other Network Elements in vMRF 1.4

2.7.4.1   General

The lowest interoperable releases are described in Table 4.

Table 4    Lowest Interoperable Releases

MTAS

16A

vMTAS

16A

OSS-RC

17B

ENM

17B

NeLS

1

2.7.4.1.1   Multimedia Telephony Application Server (MTAS)

vMRF 1.4 is compatible with the following MTAS releases: 4.0, 4.1, 4.2, 4.4, 4.5, 4.6, 4.7, and 4.8.

2.7.4.1.2   Virtual Multimedia Telephony Application Server (vMTAS)

vMRF 1.4 is compatible with the following vMTAS releases: 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6.

2.7.4.1.3   OSS-RC

vMRF 1.4 is compatible with the following OSS-RC releases: 17B, 18A.

vMRF 1.4 has only "treat as" support in OSS-RC, meaning OSS-RC treats vMRF 1.4 as vMRF 1.3 with all basic functionality supported (including new alarms), but not the new vMRF 1.4 configuration attributes or PM counters.

2.7.4.1.4   Ericsson Network Manager (ENM)

vMRF 1.4 is compatible with the following ENM release: 17B

Full functionality support for vMRF 1.4 is provided by the following ENM release: 18A.

2.7.4.1.5   Network License Server (NeLS)

vMRF 1.4 is compatible with the following NeLS releases: 1, 2.

2.7.5   Other Network Elements in vMRF 1.5.0

2.7.5.1   General

The lowest interoperable releases are described in Table 5.

Table 5    Lowest Interoperable Releases

MTAS

16A

vMTAS

16A

OSS-RC

17B

ENM

17B

NeLS

1

2.7.5.1.1   Multimedia Telephony Application Server (MTAS)

vMRF 1.5.0 is compatible with the following MTAS releases: 4.0, 4.1, 4.2, 4.4, 4.5, 4.6, 4.7, and 4.8.

2.7.5.1.2   Virtual Multimedia Telephony Application Server (vMTAS)

vMRF 1.5.0 is compatible with the following vMTAS releases: 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6.

2.7.5.1.3   OSS-RC

vMRF 1.5.0 is compatible with the following OSS-RC releases: 17B, 18A.

vMRF 1.5.0 has only "treat as" support in OSS-RC, meaning OSS-RC treats vMRF 1.5.0 as vMRF 1.3 with all basic functionality supported (including new alarms), but not the new vMRF 1.5.0 configuration attributes or PM counters.

2.7.5.1.4   Ericsson Network Manager (ENM)

vMRF 1.5.0 is compatible with the following ENM release: 17B

Full functionality support for vMRF 1.5.0 is provided by the following ENM release: 18A.

2.7.5.1.5   Network License Server (NeLS)

vMRF 1.5.0 is compatible with the following NeLS releases: 1, 2.

2.7.6   Other Network Elements in vMRF 1.6.0

2.7.6.1   General

The lowest interoperable releases are described in Table 6.

Table 6    Lowest Interoperable Releases

MTAS

16A

vMTAS

16A

OSS-RC

17B

ENM

17B

NeLS

1

2.7.6.1.1   Multimedia Telephony Application Server (MTAS)

vMRF 1.6.0 is compatible with the following MTAS releases: 4.4, 4.6, 4.7, 4.8, 4.9, 4.10, and 4.11.

2.7.6.1.2   Virtual Multimedia Telephony Application Server (vMTAS)

vMRF 1.6.0 is compatible with the following vMTAS releases: 1.6, 1.7, 1.8, 1.9, 1.10, and 1.11.

2.7.6.1.3   OSS-RC

vMRF 1.6.0 is compatible with the following OSS-RC releases: 17B, 18A, and 18B.

vMRF 1.6.0 has only "treat as" support in OSS-RC, meaning OSS-RC treats vMRF 1.6.0 as vMRF 1.3 with all basic functionality supported (including new alarms), but not the new vMRF 1.6.0 configuration attributes or PM counters.

2.7.6.1.4   Ericsson Network Manager (ENM)

vMRF 1.6.0 is compatible with the following ENM release: 17B

Full functionality support for vMRF 1.6.0 is provided by the following ENM release: 18A.

2.7.6.1.5   Network License Server (NeLS)

vMRF 1.6.0 is compatible with the following NeLS release: 2.

3   Interfaces

This section describes interface changes between the existing and new revisions of the product.

3.1   Interfaces in vMRF 1.1

This section describes the introduced interface changes.

3.1.1   Inter-node Interfaces

There are no changes to the inter-node interfaces.

3.1.2   Operation and Maintenance

This section describes changes to attributes, alarms, events and notifications, triggers, and counters.

3.1.2.1   Configuration

This section lists changes in attributes. There are no changed, deprecated, obsolete, or new attributes.

3.1.2.2   Fault Management

This section lists changes in alarms.

3.1.2.2.1   Deleted Alarms

Table 7 shows the deleted alarms.

Table 7    Deleted Alarms

Alarm Name

COM SA, AMF SI Unassigned

COM SA, CLM Cluster Node Unavailable

3.1.2.2.2   New Alarms

Table 8 shows the new alarms.

Table 8    New Alarms

Alarm Name

Description

MRF IP Auto-Configuration Failure

The alarm is raised when IP auto-configuration of a media IP address in a VM fails, for example, if the DHCP client cannot obtain, renew, or rebind an IP address, or if the lease time of the IP address ends.

MRF Next Hop Router Unreachable

The alarm is issued when connection from VM to next hop router is lost, that is, if a vMRF VM does not receive ARP reply (IPv4) or neighbor advertisement message (IPv6) from the next hop router before the response timer expires.

3.1.2.3   Events and Notifications

This section lists changes in events and notifications. There are no changed or deleted events and notifications.

3.1.2.3.1   New Event and Notifications

Table 9 shows the alarms that have been converted into events.

Table 9    New Events and Notifications

Event or Notification Name

Description

COM SA, AMF SI Unassigned

Former alarm converted into event.

COM SA, CLM Cluster Node Unavailable

Former alarm converted into event.

3.1.2.4   Counters

There are no changed, deleted, deprecated, obsolete, or new counters.

3.2   Interfaces in vMRF 1.2

This section describes the introduced interface changes.

3.2.1   Inter-node Interfaces

There are no changes to the inter-node interfaces.

3.2.2   Operation and Maintenance

This section describes changes to attributes, alarms, events and notifications, triggers, and counters.

3.2.2.1   Configuration

This section lists changes in attributes. There are no changed, deprecated, obsolete, or new attributes.

3.2.2.2   Fault Management

This section lists changes in alarms. There are no new, changed or deleted alarms.

3.2.2.3   Events and Notifications

This section lists changes in events and notifications. There are no changed or deleted events and notifications.

3.2.2.3.1   New Events

The new events are shown in Table 10.

Table 10    New Events

Event Name

MRF Compute Resource Lost

3.2.3   Counters

There are no changed, deleted, deprecated, obsolete, or new counters.

3.3   Interfaces in vMRF 1.3

This section describes the introduced interface changes.

3.3.1   Inter-node Interfaces

3.3.2   Operation and Maintenance

3.3.2.1   Configuration

This section lists changes in attributes. There are no changed, deprecated, or obsolete attributes.

3.3.2.1.1   New Attributes

This section lists changes in attributes. There are no changed or deprecated attributes.

New attributes are listed in Table 11.

Table 11    New Attributes for EVS

MO Class Name

Attribute Name

Description

MrfData

evsConfDataMoRef

Contains a reference to the EvsConfData MO instance associated with this MrfData MO.

EvsConfData

supportedBitRatesRangeBegin

Specifies the beginning of the supported bit rate range of EVS audio codec.

supportedBitRatesRangeEnd

Specifies the end of the supported bit rate range of EVS audio codec.

supportedBwRange

Specifies the supported audio bandwidth range of EVS audio codec.

SctpProfile

maxSctpPduSize

The maximum size of the SCTP PDU towards the Multimedia Telephony Application Server (MTAS).

3.3.2.2   Fault Management

This section lists changes in alarms. There are no changed or new alarms.

3.3.2.3   Events and Notifications

This section lists changes in alarms. There are no changed, deleted or new alarms.

3.3.3   Counters

There are no new, changed, deprecated, or obsolete counters.

3.4   Interfaces in vMRF 1.4

This section describes the introduced interface changes.

3.4.1   Inter-node Interfaces

3.4.2   Operation and Maintenance

3.4.2.1   Configuration

This section lists changes in attributes. There are no changed, deprecated, or obsolete attributes.

3.4.2.1.1   New Attributes

This section lists changes in attributes. There are no changed, or deprecated attributes.

New attributes are listed in Table 12.

Table 12    New MO Attributes

MO Class Name

Attribute Name

Description

TsTone

For the list of all the attributes refer to the TsTone MO in the MOM.

Configurable attributes for the Tone Sender service.

3.4.2.2   Fault Management

This section lists changes in alarms. There are no changed or new alarms.

3.4.2.3   Events and Notifications

This section lists changes in alarms. There are no changed, deleted or new alarms.

3.4.3   Counters

There are no new, changed, deprecated, or obsolete counters.

3.5   Interfaces in vMRF 1.5.0

This section describes the introduced interface changes.

3.5.1   Inter-node Interfaces

3.5.2   Operation and Maintenance

3.5.2.1   MOs

This section lists changes in MOs.

New MOs are shown in Table 13.

Table 13    New MOs

MO Class Name

Description

ChainCertificate

Chain certificate belonging to the credential.

Changed MOs are shown in Table 14.

Table 14    Changed MOs

MO Class Name

Description

FmAlarm

An FmAlarm instance represents an active alarm. An alarm is a persistent indication of a fault that clears only when the triggering condition has been resolved.

FmAlarmType

A specific kind of alarm that can be reported, for example "power failure".


In an X.733 context it maps to event type, probable cause, and specific problem. The same principle is used for alert types as for alarm types.

3.5.2.2   Configuration

This section lists changes in attributes.

3.5.2.2.1   New Attributes

New attributes are listed in Table 15.

Table 15    New MO Attributes

MO Class Name

Attribute Name

Description

CertMCapabilities

keySupport

List of the key types the ME supports.

EnrollmentAuthority

reservedBy

The MO Distinguished Names using this EnrollmentAuthority.

FmAlarm

originalAdditionalText

The additional text set when the alarm was raised.


This attribute is set when the alarm is raised and will not change during the alarm's lifetime.

originalEventTime

The timestamp when the alarm was raised.


This attribute is set when the alarm is raised and will not change during the alarm's lifetime.

originalSeverity

The perceived severity set when the alarm was raised.


It will not change during the alarm's lifetime.


Specification: RFC3877

FmAlarmType

configuredSeverity

Gives the possibility to configure the perceived severity for all alarms of this type.


If set, this value overrides the perceived severity provided by the alarming object. Setting this attribute has no impact on existing alarms, only new and updated ones.


Specification: RFC3877

defaultSeverity

The default perceived severity for all alarms of this type. Not set means alarms of this type can be assigned different severities.


Specification: RFC3877

NodeCredential

subjectAltName

The subjectAltName can be specified either as an IP address or a FQDN.

Snmp

engineId

Unique identifier of the SNMP agent. Only applicable when using SNMPv3.

TrustedCertificate

reservedBy

The Distinguished Names of MOs using this TrustedCertificate.

3.5.2.2.2   Changed Attributes

Changed attributes are listed in Table 16.

Table 16    Changed MO Attributes

MO Class Name

Attribute Name

Description

EnrollmentAuthority

enrollmentCaCertificate

The trusted cerificate of the RA or CA used for enrollment authentication. Represents the certificate by the DN of the appropriate TrustedCertificate MO. The RA or CA certificate provided in the PKI response is authenticated by this trusted certificate. If this attribute has any value, the attribute enrollmentCaFingerprint is ignored.

EnrollmentServer

uri

The URI of the enrollment server. The URI consists of a protocol, an IP or DNS address and an optional port number. Specify the optional port designation by appending a colon followed by the port number to the host part, for example, 192.168.33.27:8080. If no port number is provided, the default port is used.


For SCEP, the URI contains the relative URI of the enrollment CA HTTP Common Gateway interface (CGI) script path, which is the resource identifier of the resource on the server which will process the enrollment request.

FmAlarm

activeSeverity

The perceived severity of the alarm.


It may change during the alarm's lifetime.


Specification: RFC3877

additionalInfo

Further information about the problem.


The information is represented as a set of data structures with two items of information, an identifier and a value. It may change during the alarm's lifetime.

eventType

General category for the alarm.


Specification: ITU-T X.733 X.736

probableCause

Qualifies and provides further information on the reason for the event.


A standard set of probableCause values is provided in the ERICSSON-ALARM-PC-MIB.

sequenceNumber

A unique identity for every notification sent.


This identity changes at every notification, that is, severity change and information change. It is not the same as the fmAlarmId as multiple notifications may be sent for one alarm instance.

specificProblem

Provides further refinement to the information given by probableCause.


Can be used to find an associated operating instruction (OPI).

ManagedElement

dnPrefix

It provides naming context that allows the managed objects to be partitioned into logical domains. A Distingushed Name (DN) is defined by 3GPP TS 32.300, which splits the DN into a DN Prefix and Local DN, for example DN format: dnPrefix=<DN Prefix>, localDn =<Local DN>Fault Management: dnPrefix does not impact Fault Management, since an NMS recognises a Managed Element by IP address Performance Management (PM): The dnPrefix is present in the PM Data file, Result Output Period (ROP) file, if the dnPrefix attribute is specified, that is, not an empty string.

NodeCredential

keyInfo

Specifies the key type and length that is used for the next enrollment.


Mandatory for actions startOfflineCsrEnrollment or startOnlineEnrollment.


For the supported key types see CertMCapabilities MO keySupport attribute. Deprecated key types are not recommended for new enrollments.

3.5.2.2.3   Deprecated Attributes

Deprecated attributes are listed in Table 17.

Table 17    Deprecated MO Attributes

MO Class Name

Attribute Name

FmAlarmType

moClasses

ManagedElement

dateTimeOffset

productIdentity

localDateTime

timeZone

TrustedCertificate

reservedByCategory

3.5.2.3   Fault Management

This section lists changes in alarms. There are no changed or new alarms.

3.5.2.4   Events and Notifications

This section lists changes in alarms. There are no changed, deleted or new alarms.

3.5.3   Counters

There are no new, changed, deprecated, or obsolete counters.

3.6   Interfaces in vMRF 1.6.0

This section describes the introduced interface changes.

3.6.1   Inter-node Interfaces

3.6.2   Operation and Maintenance

3.6.2.1   MOs

There are no new or deleted MOs.

3.6.2.2   Configuration

There are no new or deprecated attributes.

3.6.2.2.1   Changed Attributes

Changed attributes are listed in Table 18.

Table 18    Changed MO Attributes

MO Class Name

Attribute Name

Description

Snmp

agentAddress

Listen addresses for the SNMP agent.
Attribute defines ports and IP addresses the agent listens to for incoming SNMP requests that use UDP protocol. Typical configurations uses IP address 0.0.0.0 (IPv4) or :: (IPv6) and port 161, which means that the standard SNMP port is used on all interfaces.

agentAddressDtls

Listen addresses for SNMP agent that uses DTLS.
Attribute defines ports and IP addresses the agent listens to for incoming SNMP requests that use DTLS transport protocol. The typical configuration uses IP address 0.0.0.0 (IPv4) or :: (IPv6) and port 10161. This means that the standard port for SNMP over DTLS is used on all interfaces.

3.6.2.3   Fault Management

This section lists changes in alarms. There are no changed or new alarms.

3.6.2.4   Events and Notifications

This section lists changes in alarms. There are no changed, deleted or new alarms.

3.6.3   Counters

There are no new, changed, deprecated, or obsolete counters.

4   Summary of Impacts per Feature

This section summarizes the impact per feature when the feature is turned on.

The description of impact is as follows:

A summary of impacts per feature is shown in Table 19.

Table 19    Summary of Impacts per Feature

Feature

Impact

Basic or Optional


New or Enhanced

Feature Number

Relation to Other Features or Nodes

Release of Feature Introduction

 

Consumer Communication

No Impact

Basic, Enhanced

FAJ 801 0891

None

vMRF 1.1

Network-redundant upgrade method

No Impact

New, Optional

None

vMRF 1.2

Workflow-based VNF operations

No Impact

New, Optional

None

Enhanced Voice Services

No Impact

New, Optional

FAJ 801 0893

NeLS

vMRF 1.3

Workflow-based VNF operations enhancement: Upgrade workflow

No Impact

Enhanced, Optional

None

Platform automatic IP address configuration

No Impact

New, Optional

None

vMRF 1.4

Consumer Communication enhancement: Tone Sender Service Configuration

No Impact

Basic, Enhanced

FAJ 801 0891

None

vMRF 1.4

VMware deployment enhancement: Support for VMware vCloud Director

No Impact

Basic, Enhanced

FAJ 801 0891

None

vMRF 1.6.0

VMware deployment enhancement: Open VM Tools

No impact

Basic, Enhanced

FAJ 801 0891

None

RBAC Enhancement

No Impact

Basic, Enhanced

FAJ 801 0891

None

Support for watchdog feature

No impact

Basic, Enhanced

FAJ 801 0891

None

5   Impact on vMRF Features

This section shows the impact on the vMRF features when the feature is turned on.

5.1   Impact on vMRF Features from vMRF 1.0 to vMRF 1.1

5.1.1   Media Stream Processing Enhancements

5.1.1.1   Description

The G.722 audio codec has been introduced. The G.722 codec operates at a sampling rate of 16 kHz and offers audio bandwidth ranging from 50 Hz up to 7 kHz. The G.722 codec supports Packet Loss Concealment (PLC).

Adaptive jitter service has been introduced. In the beginning of the call the jitter buffer size is always the configured initial jitter buffer size, but during the call the jitter buffer size adapts to the measured jitter. Static jitter service is not supported.

5.1.2   Troubleshooting Enhancements

5.1.2.1   Description

The h.248 error codes are now expanded with descriptive text strings.

Hanging termination notification towards the controlling server has been introduced.

5.2   Impact on vMRF Features from vMRF 1.1 to vMRF 1.2

5.2.1   Upgrade Method Enhancements

5.2.1.1   Description

The network-redundant upgrade method has been introduced. Network-redundant upgrade can be performed when two vMRF VNFs are available in parallel during normal operation. During the upgrade procedure, one of them is upgraded to the new version, while the other one handles traffic uninterrupted.

5.2.2   Workflow-based VNF Life Cycle Management

5.2.2.1   Description

The workflow-based VNF Life Cycle Management (VNF-LCM) has been introduced as a primary method for VNF cluster management. The following workflow-based procedures are supported:

Scaling and termination of a vMRF VNF using VNF-LCM is only supported if the vMRF was instantiated using the LCM workflow. Manual scaling and the removal of the cluster must be performed only if the vMRF VNF was deployed manually.

5.3   Impact on vMRF Features from vMRF 1.2 to vMRF 1.3

5.3.1   Enhanced Voice Services

Transcoding support for the EVS codec is introduced. EVS is a multi-rate audio codec that operates at 8 kHz, 16 kHz, 32 kHz, and 48 kHz sampling rates, and offers full audio bandwidth ranging from 20 Hz up to 20 kHz. EVS supports bit rates from 5.9 kbps to 128 kbps. EVS supports comfort noise generation and error concealment.

The use of EVS requires the Enhanced Voice Services capacity license and connection to a Network License Server (NeLS).

5.3.2   VNF Life Cycle Management Enhancement

The network-redundant upgrade LCM operation has been introduced. This procedure can be used to upgrade the vMRF VNF to a newer version even without traffic loss, if another VNF is in operation during the upgrade.

5.4   Impact on vMRF Features from vMRF 1.3 to vMRF 1.4

5.4.1   Platform Automatic IP Address Configuration

Support for deployment without DHCP server on OpenStack has been introduced. Separate batch of HOT and example environment yaml files are included in the software delivery package for deployment with or without DHCP server configuration on OpenStack. With platform automatic IP address configuration, IP addresses are assigned by the virtualization infrastructure.

5.4.2   Tone Sender Service Configuration

The Tone Sender (TS) service can be configured by the attributes of the new TsTone MO. The TsTone MO represents a tone as used by the Tone Sender service in the vMRF. An instance of this MO exists for each tone type supported by the VNF. The MO instances are created automatically by the system. The parameters, for example, tone type, tone duration, frequencies, levels, play and pause times, can be changed.

5.5   Impact on vMRF Features from vMRF 1.4 to vMRF 1.5.0

No new features are introduced.

5.6   Impact on vMRF Features from vMRF 1.5.0 to vMRF 1.6.0

5.6.1   Support for VMware vCloud Director

Support for deployment using the cloud service VMware vCloud Director is introduced.

5.6.2   POSIX Group Enhancement

Due to RBAC Enhancement, POSIX groups do not need to be defined in the LDAP server anymore. This is a backward-compatible enhancement, that is, old LDAP server configurations can still be used.

5.6.3   Support for Watchdog Feature

Support for the watchdog feature is introduced.

The watchdog feature, when configured, supervises the status of each VM instance and restarts the instance if the watchdog does not get signal from the VM for one minute.

5.6.4   Open VM Tools

Open VM Tools (OVT) is included in the guest OS. OVT is an open source implementation of VMware Tools. It consists of virtualization utilities that improve the functionality and management of VMs within a VMware environment.