1 Overview
This section provides an overview for the Storage Engine, No Available Master Replica for PLDB alarm.
1.1 Description
This alarm is raised when the Processing Layer Database (PLDB) does not have any available master replicas.
The alarm attributes are listed and explained in Table 1:
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
Yes |
|
Module |
STORAGE-ENGINE |
|
Error Code |
10 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raised. |
|
Resource ID |
.1.3.6.1.4.1.193.169.1.1.10 |
|
Alarm Model Description |
No available master replica, Storage Engine. |
|
Alarm Active Description |
Storage Engine (PLDB): No available master replica. |
|
ITU Alarm Event Type |
communicationsAlarm (2) |
|
ITU Alarm Probable Cause |
communicationsSubsystemFailure (505) |
|
ITU Alarm Perceived Severity |
(4) – Major |
|
Originating Source IP |
Node ID where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which alarms were raised. |
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].
The possible causes of the alarm are as follows:
- Mastership change or planned master changes. In this case, the alarm must cease after some seconds
- Network problems.
1.2 Prerequisites
This section lists the prerequisites required for the procedure described in Section 2.
1.2.1 Documents
Refer to CUDB System Administrator Guide, Reference [2] for further information.
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
If the alarm is not cleared automatically in a short period of time, perform the following steps:
- Check the network connections.
- If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.