Licensing, License Key Not Available, Minor
Ericsson Centralized User Database

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

Glossary

Reference List

1   Introduction

This instruction concerns alarm handling for the Licensing, License Key Not Available, Minor alarm.

1.1   Alarm Description

This alarm is raised when the CUDB Customer Trial deployment license has entered the expiration warning period, and is about to expire.

The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

CUDB detected that the license of the CUDB Customer Trial is about to expire.

The CUDB Customer Trial is about to expire.

The available license on the node is about to expire.

License Manager

Violation of license agreements, if the new license key file is not ordered and installed before the Customer Trial license expires.

The following is the consequence for the node if the alarm is not solved:

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Auto Cease

Yes

Module

LICENSING

Error Code

3

Timestamp First

Date and time when the alarm was raised for the first time.

Repeated Counter

Number which indicates how many times the alarm was raised.

Timestamp Last

Date and time of the most recent alarm raise.

Resource ID

1.3.6.1.4.1.193.169.14.2.2.15

Alarm Model Description

License Management, Licensing

Alarm Active Description

License key not available, CUDB Customer Trial license is about to expire

ITU Alarm Event Type

qualityOfServiceAlarm (3)

ITU Alarm Probable Cause

configurationOrCustomisationError (159)

ITU Alarm Perceived Severity

(5) – Minor

Originating source IP

Node IP where the alarm was raised.

Sequence Number

Number which indicates the order in which the alarms are raised.

For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].

1.2   Prerequisites

This section provides information on the documents, tools, and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that you have read the following documents:

1.2.2   Tools

Not applicable.

1.2.3   Conditions

Not applicable.

2   Procedure

If the alarm is raised, then refer to the License Management, License Key Not Available, Reference [5] document for the procedure to perform.

Note:  
Perform only the actions that are applicable for LM deployments using ELIM license key files.


Glossary

For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [2].


Reference List

CUDB Documents
[1] CUDB Node Fault Management Configuration Guide.
[2] CUDB Glossary of Terms and Acronyms.
Other Ericsson Documents
[3] System Safety Information.
[4] Personal Health and Safety Information.
[5] License Management, License Key Not Available.


Copyright

© Ericsson AB 2016. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    Licensing, License Key Not Available, Minor         Ericsson Centralized User Database