Security, OAM User Exceeded Number Of Failed Logins
Ericsson Centralized User Database

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

Glossary

Reference List

1   Introduction

This document provides the description and troubleshooting steps to take for the Security, OAM User Exceeded Number Of Failed Logins alarm.

1.1   Alarm Description

This alarm is raised when the number of Operation and Maintenance (OAM) user login failures exceeds a configured threshold. Refer to CUDB Node Configuration Data Model Description, Reference [1] for more information.

The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Too many failed OAM user login attempts.

The number of OAM user login failures exceeded a configured threshold.

Wrong password entered too many times at the login procedure, possibly by an unauthorized user.

OAM server node.

After a configured number of failed login attempts, the user account is blocked for a certain period of time. The node cannot be accessed by that user.

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Auto Cease

No

Module

SECURITY(11)

Error Code

1

Timestamp First

Date and time when the alarm was raised for the first time.

Repeated Counter

Number which indicates how many times the alarm was raised.

Timestamp Last

Date and time of the most recent alarm raised.

Resource ID

.1.3.6.1.4.1.193.169.11.1.<IP>.<usernameLength>.<usernameASCIICode>

Alarm Model Description

Too Many Failed OAM Login Attempts, Security.

Alarm Active Description

Security: Too Many Failed OAM Login Attempts @<IP>by user <username>

ITU Alarm Event Type

securityServiceOrMechanismViolation (10)

ITU Alarm Probable Cause

authenticationFailure (600)

ITU Alarm Perceived Severity

(6) – Warning

Originating Source IP

Node ID where the alarm was raised.

Sequence Number

Number which indicates the order in which alarms were raised.

In Table 2, the indicated variables are as follows:

For more information about attribute descriptions, refer to the Alarm Format and Description section of CUDB Node Fault Management Configuration Guide, Reference [4].

1.2   Prerequisites

This section provides information on the documents, tools and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that you have read the following documents:

1.2.2   Tools

Not applicable.

1.2.3   Conditions

Not applicable.

2   Procedure

If the alarm is raised, perform the following steps:

  1. Make backup copies of the log files to preserve evidence of the possible (attempted) intrusion.
  2. Examine the security log file to determine the source of the intrusion. For more information about logging information in CUDB, refer to CUDB Node Logging Events, Reference [2].
  3. If the log file analysis indicates that an unauthorized intrusion was successful, seek further advice in order to secure the system again. For more information about security configuration in CUDB, refer to CUDB Security and Privacy Management, Reference [3].
  4. Once system security has been reestablished, manually clear the alarm according to the procedure described in CUDB Node Fault Management Configuration Guide, Reference [4].
  5. Wait for the configured time for unlock (for more information, refer to CUDB Node Configuration Data Model Description, Reference [1]), otherwise log in as OAM administrator and manually unlock the user using the following command on the System Controller (SC) given in the Alarm Active Description attribute of the alarm (<IP> variable):

    pam_tally2 -r -u <username>

  6. Further actions are outside the scope of this Operating Instruction.

Glossary

For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms And Acronyms, Reference [5].


Reference List

CUDB Documents
[1] CUDB Node Configuration Data Model Description.
[2] CUDB Node Logging Events.
[3] CUDB Security and Privacy Management.
[4] CUDB Node Fault Management Configuration Guide.
[5] CUDB Glossary of Terms And Acronyms.
Other Ericsson Documents
[6] System Safety Information.
[7] Personal Health and Safety Information.


Copyright

© Ericsson AB 2016, 2017. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document.

Trademark List
All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.

    Security, OAM User Exceeded Number Of Failed Logins         Ericsson Centralized User Database