*************************************************************************** RASC indexed textfile. Source:BCSDATUK.SRC *************************************************************************** *************************************************************************** WARNING CODES 4.12.2001 *************************************************************************** #CODE:00 CODE=00H WARNING MACRO PARAMETER ERROR. Default definition : ALARM Used by block : NONE Category : DESIGNER The warning macro is used without the CODE parameter. This code is not valid at any time. D1 - Undefined D2 - Undefined D3 - Undefined D4 - Undefined #CODE:01 CODE=01H NO AVAILABLE PCM CHANNEL GROUP 0. Default definition : UNDEFINED Default limit : 65000 Used by block : OS Category : DESIGNER A request of a channel in the common group (0) was denied. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:02 CODE=02H NO AVAILABLE PCM CHANNEL GROUP 1. Default definition : UNDEFINED Default limit : 65000 Used by block : OS Category : DESIGNER A request of a channel in the privileged group (1) was denied. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:03 CODE=03H SENDRESOURCES LIMITED. Default definition : ERROR Default limit : 100 Used by block : OS Category : DESIGNER There were not enough places in the send queues. D1 - D2 - Type of send queue 0BH ... B-Level 0CH ... C-Level 0DH ... D-Level D3 - Undefined D4 - Undefined #CODE:04 CODE=04H NO OS BUFFER AVAILABLE. Default definition : ERROR Default limit : 100 Used by block : OS Category : DESIGNER The request of an OS-buffer was denied. D1 - D2 - Datamap number 00H - 0FH D3 - Undefined D4 - Undefined #CODE:05 CODE=05H NO AVAILABLE COMMON TIMER. Default definition : ERROR Default limit : 100 Used by block : OS Category : DESIGNER A request of a timer was denied. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:06 CODE=06H SYSTEM POWERUP. Default definition : ERROR+NOPROG Default limit : 65000 Used by block : OS Category : DESIGNER System power-up restart. D1 - Undefined D2 - Undefined D3 - Undefined D4 - Undefined #CODE:07 CODE=07H NO AVAILABLE EXTRA TIMER. Default definition : ERROR Default limit : 100 Used by block : OS Category : DESIGNER A request of a timer other than common was denied. D1 - D2 - Type of timer 06H ... Periodic timer 07H ... Delayed-send timer D3 - Undefined D4 - Undefined #CODE:08,1 CODE=08H TRANSMISSION LEVEL ADJUST FAILURE. Default definition : ERROR Default limit : 65000 Used by block : SX Category : MAINTENANCE The level, requested by programming, was impossible to achieve. The range of transmission levels, possible to achieve, is not constant, but varies with the selected line impedance. When the requested level cannot be set, a level as close as possible is set instead and the warning counter is incremented. D1 - Board position 00H - 3FH D2 - Individual number D3 - Used relative send level (see message TRANSM, TRMNAK) D4 - Used relative receive level (see message TRANSM, TRMNAK) Recommended action: If the customer reports transmission level problems, the counter, associated with this warning, should be inspected. If the value is greater than zero, the counter limit should be set equal to zero. This action will generate this warning and next time the warning will be stored. The transmission level is determined by the commands for setting the nominal relative level (0140, 0141 and 1610, 1611) and by the commands for the selection and definition of transmission groups (0142, 1612 and 26xx). #CODE:09,1 CODE=09H NO AVAILABLE INDIVIDUAL AT TSU. Default definition : ERROR Default limit : 100 Used by block : TS Category : DESIGNER All individuals for the current type of tone at TSU are busy. D1 - Type of tone, repetitive or non-repetitive D2 - Current state D3 - Undefined D4 - Undefined #CODE:0A,1 CODE=0AH ELU-A LOAD EXCEEDED. Default definition : ERROR Default limit : 100 Used by block : RP (ELU-A) Category : MAINTENANCE The allowed continuous power dissipation on the ELU-A board is exceeded, which may effect the component durability. This situation can be accepted for a short time during high traffic without measurable negative effects. If this warning occurs often or during low traffic, measures should be taken to spread out the traffic over several ELU-A boards. If only one ELU-A board is available, a 200 ohm resistor should be inserted in series with each branch of the extension line in order to decrease the power dissipation. Three power limiting actions for the SLIC circuits are used by the ELU-A software : Limit 1 : voltage feed is decreased. Limit 2 : current feed changed to 850 ohm. Limit 3 : idle SLIC circuits are disabled. D1 - Current power limit Bit 7 ... 0 = Power limit 2 1 = Power limit 3 Bit 6 - 0 ... Number of lines D2 - Counter value for power limit 1. D3 - Counter value for power limit 2. D4 - Counter value for power limit 3. #CODE:0B,1 CODE=0BH REGISTER SEIZE REQUEST CANCELLED. Default definition : ERROR Default limit : 65000 Used by block : RS Category : DESIGNER A register individual seize request has been cancelled by the ordering party before completion. The cause may be lack of free register individuals, i.e. the request is placed in a queue and the time before answer was too long. The warning indicates a capacity problem. D1 - Type of register D2 - Current state D3 - Undefined D4 - Undefined #CODE:0C,5 CODE=0CH LOAD REGULATION QUEUE FULL. Default definition : UNDEFINED Default limit : 65000 Used by block : OU Category : DESIGNER This warning is sent, when there are no more free positions in the load regulation queue, handled by OU. D1 - Current number of used queue positions. D2 - Maximum number of available positions (size of queue). D3 - User identity, ST or CARD. D4 - User identity, SN or IND. #CODE:0D,5 CODE=0DH DIGITAL LINK ERROR. Default definition : UNDEFINED Default limit : 65000 Used by block : LS Category : DESIGNER This warning indicates a new alarm condition on the international / national bits, or a new alarm condition for layer 2 on the current digital link. D1 - Alarm condition 01H ... Alarm condition on the international / national bits 02H ... Alarm condition on layer 2. D2 - Card position D3 - Undefined D4 - Undefined #CODE:0E CODE=0EH RESOURCES DECREASED (first limit). Default definition : UNDEFINED Default limit : 65000 Used by block : EX Category : DESIGNER Defined by EX block. An attempt to start a new process was ignored, because all resources could not be found. As long as the resources are decreased to this limit, all attempts to initiate a new call will be ignored and a congestion tone will be generated towards the extension in question. This is the first step, taken in order to decrease the system load, another step is taken, if the system load is even more increased, see W.EXBLOCKED. D1 - Undefined D2 - Undefined D3 - Undefined D4 - Undefined #CODE:0F CODE=0FH RESOURCES DECREASED (second limit). Default definition : ERROR Default limit : 0 Used by block : EX Category : DESIGNER Defined by EX block. An attempt to start a new process was ignored because all resources could not be found. When this 'error' is detected, all extensions are blocked in order to decrease the system load. A blocked extension is not allowed to initiate a new call, so the extension will be connected to 'silence' instead of dialtone as long as the low resource limit is maintained. This is the second step, taken in order to decrease the system load, the first could have been already executed, see W.EXCONGEST. D1 - Undefined D2 - Undefined D3 - Undefined D4 - Undefined #CODE:10 CODE=10H SYSTEM RESTART. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : OS Category : DESIGNER This code is used by OS to report the restart reason. D1 - Last OS phase before restart. See 'OSLPHASEOLD' D2 - Last executed ST before restart. See 'OSLJOBSTOLD' D3 - Restart reason 00H ... Purpose of restart not specified 01H ... FW remote upgrading, set by SU 03H ... E2 conversion, set by CE 04H ... Warning category STOP, set by OM 05H ... Restart with OM Tool, set by OM 06H ... Restart with system instrument, set by OM 07H ... Error in non-mapped RAM, set by OS 08H ... Restart of a single peripheral interface board, set by OM D4 - Undefined The restart purpose is not available, when the central software is compiled in Release-mode. This code is also used by peripheral interface boards to force the shutdown and restart of a single card position after a major internal error has been detected. D1 - Last executed process ID FFH ... Process ID not known D2 - Restart reason, defined by the RTOS on the given peripheral interface board D3 - Last executed signal number (high byte) D4 - Last executed signal number (low byte) #CODE:11,0 CODE=11H DATA MEMORY ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : OS Category : MAINTENANCE OS has found an error in the data memory during the RAM test at restart. D1 - D2 - Map number 00H - 0FH Mapped RAM 80H, 82H, 83H Mapped RAM (extended OS area) Recommended action: If the fault remains after restart, the CPU-board of the system should be replaced. Alternatively, the identified memory circuit can be replaced. To prevent a loss of programmed data if the entire board is replaced, all EEPROM-circuits on the old board can be moved to corresponding positions on the new baord. #CODE:11,1 CODE=11H DATA MEMORY ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : OS Category : MAINTENANCE OS has found an error in the data memory during the RAM test at restart. D1 - D2 - Map number 00H - 0FH Mapped RAM 80H, 82H - 87H Mapped RAM (extended OS area) 81H RealTimeClock error or battery backed up RAM D3 - Undefined D4 - Undefined Recommended action: If the fault remains after restart, the CPU-board of the system should be replaced. Alternatively, the identified memory circuit can be replaced. To prevent a loss of programmed data if the entire board is replaced, all EEPROM-circuits on the old board can be moved to corresponding positions on the new board. #CODE:12 CODE=12H PROGRAM MEMORY ERROR. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : OS Category : MAINTENANCE OS has found an error in the program memory. If the error is found in a program map, that particular map will not be activated. D1 - Type of error 01H ... Checksum error 02H ... Insufficient data memory D2 - Map number FFH ... System map D3 - Undefined D4 - Undefined Recommended action: If the fault is an invalid checksum, verify that the identified program map is properly mounted, and restart the system. If the fault remains, replace the CPU board or the identified circuit. If the fault is insufficient data memory, and new programs have been mounted on the board, verify that the existing amount of data memory is sufficient for the new programs. If the fault has not occurred in conjunction with a change to a new software, the probable reason is a faulty data memory. Replace the CPU-board in the system. To prevent a loss of programmed data if the entire board is replaced, all EEPROM-circuits on the old board can be moved to corresponding positions on the new board. #CODE:12,13 CODE=12H PROGRAM MEMORY ERROR. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : OS, CPUDx Category : MAINTENANCE OS has found an error in the program memory. If the error is found in a program map, that particular map will not be activated. D1 - Type of error 01H ... Checksum error 02H ... Insufficient data memory 04H ... CPU-Dx upgrade handler error report D2 - Map number D2 - Board position FFH ... System map 00H - 3FH ... Errorneous board FFH ... Illegal state in upgrade handler D3 - Undefined D3 - Board state 00H ... No upgrade memory reported 01H ... Up and running 02H ... Clear is requested 03H ... Upgrade memory is cleared 04H ... Error during clear 05H ... Memory image transmission 06H ... Memory image OK 07H ... Memory image error FFH ... No CTYPEANSW message received Internal state information (D2 = FFH) D4 - Undefined D4 - Error reason 01H ... Upgrade not available 02H ... Upgrade sequence error 03H ... Upgrade sector error (erase / write) 04H ... Upgrade erase error (entire chip) 05H ... Upgrade erase timeout (entire chip) 06H ... Upgrade write error 0BH ... No data available 0CH ... Odd number of bytes 0DH ... Data verification error 0EH ... Checksum error 0FH ... Message sequence error 10H ... Message checksum error Internal state information (D2 = FFH) Recommended action: If the fault is an invalid checksum, verify that the identified program map is properly mounted, and restart the system. If the fault remains, replace the CPU board or the identified circuit. If the fault is insufficient data memory, and new programs have been mounted on the board, verify that the existing amount of data memory is sufficient for the new programs. If the fault has not occurred in conjunction with a change to a new software, the probable reason is a faulty data memory. Replace the CPU-board in the system. To prevent a loss of programmed data if the entire board is replaced, all EEPROM-circuits on the old board can be moved to corresponding positions on the new board. #CODE:13,0 CODE=13H INVALID SIGNAL TYPE IN MESSAGE. Default definition : ERROR+TRIG Used by block : OS Category : DESIGNER The signal type (ST) in the message was not valid. D1 - Job identity of the sender (usually signal type ST) D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:13,1 CODE=13H INVALID SIGNAL TYPE IN MESSAGE. Default definition : ERROR+TRIG Used by block : OS Category : DESIGNER The signal type (ST) in the message was not valid. D1 - Job identity of the sender (usually signal type ST) D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 #CODE:14 CODE=14H OS INTERNAL ERROR. Default definition : ERROR Used by block : OS Category : DESIGNER This code is used by OS to signal internal errors such as pointer errors, counter errors, etc. D1 - D2 - Sequence number 80H - 8FH ... From file OSHWI* 90H - 9FH ... From file OSTIM* D3 - Undefined D4 - Undefined #CODE:15 CODE=15H TIMER ERROR. Default definition : ERROR+TRIG Used by block : OS Category : DESIGNER Some errors have been found. Errors for normal timers : D1 - Type of error D2 - Additional data 01H ... Timer already released Last job ID 02H ... Timer number error Given number 03H ... Timer ID error Given timer job ID Errors for extra timers : D1 - Type of error D2 - Additional data 10H ... Message length error Given length 11H ... Timer timedata error Given timedata D3 - Undefined D4 - Undefined #CODE:16 CODE=16H BUFFER USAGE ERROR. Default definition : ERROR+TRIG Used by block : OS Category : DESIGNER The OS.BUFFER macro has been used in an invalid way. D1 - BUFFLOG from buffer (last executed operation). 00H ... Linked buffer, last in the chain. 01H - EFH ... Linked buffer, next buffer forward. F0H ... Released buffer. F1H ... Job buffer, OS own (buffer 0). F2H ... Job buffer, common. F3H ... Keep marked buffer. F4H ... Requested buffer. F5H ... Unlinked buffer. F6H - FFH ... Not valid, spare for future use. D2 - BUFFJID from buffer (job identity). 40H - FBH ... OS-logged jobsignal type (ST, job enter) FEH ... Buffer is handled during init. FFH ... OS-handled buffer (job exit) D3 - Undefined D4 - Undefined #CODE:17 CODE=17H BUFFER ERROR. Default definition : ERROR+TRIG Used by block : OS Category : DESIGNER Buffer error. D1 - Type of buffer error D2 - Additional data 01H ... Data error (address) Calculated buffer number 02H ... Data error (buffer number) Given buffer number 03H ... Data error (link identity) Given link ID 04H ... Data error (not in chain) Given link ID 05H ... Data error (job ID) Buffer job ID 06H ... Data error (init) Map number 10H ... Buffer error (BUFFNUM) Current buffer number 11H ... Buffer error (BUFFLOG) Current buffer number 12H ... Buffer error (BUFFJID) Current buffer number 13H ... Buffer error (linked chain) Current buffer number 14H ... Buffer error (endless link) Current buffer number 20H ... Buffer handler (OSBUFF$QNT) Current value 21H ... Buffer handler (OSBUFF$FRE) Current value 22H ... Buffer handler (OSBUFF$BSY) Current value 23H ... Buffer handler (OSBUFF$LST) Current value D3 - Undefined D4 - Undefined #CODE:18 CODE=18H JOBQUE FULL AT SEND. Default definition : STOP Used by block : OS Category : DESIGNER There was no more job queue available, when a send was attempted. D1 - D2 - Type of send queue 0BH ... B-Level 0CH ... C-Level 0DH ... D-Level D3 - Undefined D4 - Undefined #CODE:19 CODE=19H SEND ERROR. Default definition : ERROR+TRIG Used by block : OS Category : DESIGNER A fatal error in the data was found by OS. D1 - Message length D2 - Type of error 01H ... Message length error D3 - Undefined D4 - Undefined #CODE:1A,0 CODE=1AH SEND RATE ERROR. Default definition : ERROR Used by block : OS Category : DESIGNER The number of times, OS.SEND was used in a job, exceeded the recommended limit. D1 - Current state D2 - The actual number of times, OS.SEND was used. D3 - Undefined D4 - Undefined #CODE:1A,1 CODE=1AH SEND RATE ERROR. Default definition : ERROR Used by block : OS Category : DESIGNER The number of times, OS.SEND was used in a job, exceeded the recommended limit. D1 - Current state D2 - The actual number of times, OS.SEND was used. D3 - Current CODE D4 - Current SUBCODE #CODE:1B CODE=1BH COMMUNICATION ERROR SP-OS. Default definition : ERROR Used by block : OS Category : DESIGNER An invalid or illegally used command from SP has been detected. D1 - D2 - Command number and parameter. D3 - Undefined D4 - Undefined #CODE:1C CODE=1CH LENGTH ERROR IN MESSAGE TO RP. Default definition : ERROR Used by block : OS Category : DESIGNER The maximum message length was exceeded. D1 - Current INFCODE D2 - The illegal length. D3 - Undefined D4 - Undefined #CODE:1C,11 CODE=1CH LENGTH ERROR IN MESSAGE TO RP. Default definition : ERROR Used by block : OS Category : DESIGNER The maximum message length was exceeded. D1 - Current INFCODE D2 - The illegal length. D3 - INFCODE of the logged message D4 - SUBCODE of the logged message #CODE:1D CODE=1DH DATA MEMORY NOT SUFFICIENT. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : OS Category : MAINTENANCE OS could not allocate all requested dynamic memory in the MDATA class. On startup, the operating system allocates data memory depending on the number of program maps mounted on the CPU-board and on the number of boards, used in the system. The memory requirement varies considerably for the different board types available. This warning is sent, if the system finds that the available data memory area is insufficient. D1 - D2 - Datamap number 00H - 0FH FFH ... Unmapped memory area D3 - Undefined D4 - Undefined Recommended action: The most likely cause of this warning is that the capacity of the system has been exceeded due to the use of too many ELUD type boards. Remove one ELUD type board. #CODE:1E CODE=1EH MAP PLACEMENT ERROR, ACTIVATED. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : OS Category : MAINTENANCE A program map is not placed in the expected position. The map will be activated. D1 - Expected position, read from the map header. D2 - Actual position. D3 - Undefined D4 - Undefined #CODE:1F CODE=1FH MAP PLACEMENT ERROR, NOT ACTIVATED. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : OS Category : MAINTENANCE A program map is not placed in the expected position. The map will not be activated. D1 - Expected position, read from the map header. D2 - Actual position. D3 - Undefined D4 - Undefined #CODE:20 CODE=20H ILLEGAL ST REPORTED. Default definition : ERROR+NOPROG Used by block : OS Category : DESIGNER OS has found a signal type (ST) out of limits or identical ST in several job signal tables. In the later case the first occurrence will be considered valid. D1 - Received ST D2 - Map number D3 - Undefined D4 - Undefined #CODE:21 CODE=21H UNDEFINED PROGRAM ADDRESS. Default definition : ERROR Used by block : OS Category : DESIGNER OS considers a program address as illegal or undefined. D1 - D2 - Type of program address 01H ... SWI (MAPJSR) 02H ... SWI2 or SWI3 D3 - Undefined D4 - Undefined #CODE:22,1 CODE=22H MESSAGE TO/FROM RP DISCARDED. Default definition : ERROR Used by block : OS Category : DESIGNER OS has received a message to / from a RP, but the message is not accepted as valid. The message is not passed to the final receiver. D1 - Card position (sender or receiver) D2 - Type of error Bit 0 ... Illegal Data Field Discriminator (DFD) Bit 1 ... Illegal message type sequence Bit 2 ... Invalid ID in message Bit 3 ... Invalid part number Bit 4 ... Invalid ML Bit 5 ... Spare Bit 6 ... Illegal IND number Bit 7 ... No OS buffer available D3 - Undefined D4 - Undefined #CODE:24 CODE=24H OU ROUTINE NOT READY. Default definition : ERROR Used by block : OU Category : DESIGNER This code is used by OU to warn, when a call to a routine is made, that is not yet ready. D1 - Undefined D2 - Undefined D3 - Undefined D4 - Undefined #CODE:25 CODE=25H OU INTERNAL ERROR. Default definition : ERROR Used by block : OU Category : DESIGNER This code is used by OU to signal internal errors such as pointer errors, counter errors, etc. D1 - D2 - Sequence number 01H ... Channel handler, file OUCHA* 02H ... Utility handler, file OUSUB* D3 - Undefined D4 - Undefined #CODE:26 CODE=26H STATEVALUE ERROR. Default definition : ERROR+TRIG Used by block : OU Category : DESIGNER The specified state could not be found. The warning is sent by the OU.STATE routine. D1 - INFCODE in message D2 - State D3 - Undefined D4 - Undefined #CODE:27 CODE=27H ILLEGAL PCM CHANNEL ACCESS. Default definition : ERROR+TRIG Used by block : OU Category : DESIGNER OU denied the requested operation on the PCM channel. The cause may be an invalid channel number, an invalid channel state or an illegal job identity. D1 - Channel number D2 - Job identity (usually signal type ST) of the channel user D3 - Undefined D4 - Undefined #CODE:28 CODE=28H E2 READ ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : E2 Category : MAINTENANCE A read attempt from the E2-area failed. D1 - D2 - Map number D3 - Undefined D4 - Undefined Recommended action: If an occasional warning of this type is received, but the system otherwise shows no symptoms of faults, that can be related to the EEPROM, such warnings can be ignored. If several warnings of this type are obtained or the system shows fault symptoms that probably are related to the EEPROM, the CPU board should be replaced. As an alternative, the identified EEPROM circuit can be replaced. The system must be reprogrammed, preferrable from a backup. #CODE:29 CODE=29H E2 WRITE ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : E2 Category : MAINTENANCE A write attempt in the E2-area failed. D1 - D2 - Map number D3 - Undefined D4 - Undefined Recommended action: If an occasional warning of this type is received, but the system otherwise shows no symptoms of faults, that can be related to the EEPROM, such warnings can be ignored. If several warnings of this type are obtained or the system shows fault symptoms that probably are related to the EEPROM, the CPU board should be replaced. As an alternative, the identified EEPROM circuit can be replaced. The system must be reprogrammed, preferrable from a backup. #CODE:2A CODE=2AH E2 MAP ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : E2 Category : MAINTENANCE An E2 map, that has previously been used by the E2 handler, can no longer be found. D1 - D2 - Map number D3 - Undefined D4 - Undefined #CODE:2B CODE=2BH DIRECTORY NUMBER ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : E2 Category : MAINTENANCE Two identical directory numbers have been found during the start-up of the E2 data handler. D1 - Directory number, high byte D2 - Directory number, low byte D3 - Undefined D4 - Undefined Recommended action: Use command 5901 to find out, to which function the directory number belongs to. Replace this directory number temporarily with a free (non-utilised) number. Then use the function 'eeprom resources/test'. This will cause the internal directory number table of the exchange to be updated. See also warning code 2CH. With command 5901 it is now possible to find out, which other function occupies the directory number in question. Make a definitive correction of the directory numbers for the two functions. #CODE:2C CODE=2CH ERROR IN E2DATA FOUND BY E2TEST. Default definition : ALARM+EXTERN+ACTIVE Used by block : E2 Category : MAINTENANCE Some error in the E2 data structure was found by the E2 handler during internal tests, started by the supervision programs. D1 - Test number 01H ... Verify the RAM copy of the installed E2-maps. The error is always corrected. 02H ... Search for base records with identical identity. 03H ... Search for base records with identical directory number. 04H ... Verify base record counter. 05H ... Search for linked records with non-matching base record ID. 06H ... Search for record pointers to non-installed maps. 07H ... Search for record pointers to non-valid buffers. 08H ... Search for record pointers to non-seized buffers. 09H ... Search for seized buffers, which are not properly linked. 0AH ... Search for linked records with identical identity. 0BH ... Verify checksums of all installed maps. D2 - Number of errors found in this test D3 - Undefined D4 - Undefined Recommended action: This test can be repeated manually from RASC without the generation of warnings. However, subtest number 1 repairs found errors, so these errors will normally not appear again. Use the function 'eeprom resources/repair' in RASC to repair the errors. NOTE: The repair function is normally executed by removing memory areas and the risk exists that certain functions can be lost. If the repair fails, replace the CPU-board and perform a cold start of the system. The system must then be reconfigured, either manually or from a back-up, if one exists. #CODE:2D CODE=2DH FREE BUFFER CHECK FAILED. Default definition : STOP Used by block : OS Category : MAINTENANCE This code is only used, when the periodic resource check, initiated by the supervision programs, failed. The warning indicates that the maximum number of free buffers, that has been available since the last check, is smaller than the anticipated number. The cause can be a program, that does not release resources correctly, or it can be that the system is used in a way, that locks up resources permanently. In the latter case, the warning code can be removed. D1 - D2 - Data map number D3 - Undefined D4 - Undefined #CODE:2E CODE=2EH FREE TIMER CHECK FAILED. Default definition : STOP Used by block : OS Category : MAINTENANCE This code is only used, when the periodic resource check, initiated by the supervision programs, failed. The warning indicates that the maximum number of free timers, that has been available since the last check, is smaller than the anticipated number. The cause can be a program, that does not release resources correctly, or it can be that the system is used in a way, that locks up resources permanently. In the latter case, the warning code can be removed. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:2F CODE=2FH FREE CHANNEL CHECK FAILED. Default definition : STOP Used by block : OU Category : MAINTENANCE This code is only used, when the periodic resource check, initiated by the supervision programs, failed. The warning indicates that the maximum number of free PCM channels, that has been available since the last check, is smaller than the anticipated number. The cause can be a program, that does not release resources correctly, or it can be that the system is used in a way, that locks up resources permanently. In the latter case, the warning code can be removed. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:30 CODE=30H INVALID MESSAGE AT SIGNAL INPUT. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The received message is not valid at the current signal input. D1 - D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:30,2 CODE=30H INVALID MESSAGE AT SIGNAL INPUT. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The received message is not valid at the current signal input. D1 - D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:31 CODE=31H INVALID MESSAGE IN STATE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The received message is not valid in the current state. D1 - Current state D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:31,2 CODE=31H INVALID MESSAGE IN STATE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The received message is not valid in the current state. D1 - Current state D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:32 CODE=32H NO PROCESS FOR MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER A message is received to a nonexistent process. D1 - D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:32,2 CODE=32H NO PROCESS FOR MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER A message is received to a nonexistent process. D1 - D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:33 CODE=33H INVALID MESSAGE LENGTH IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The length of the received message is not valid. This code is intended for programs, that use the ML byte to evaluate the data in the message. A message length, that is otherwise outside the valid range, is detected by OS. D1 - Received message length (ML) D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:33,2 CODE=33H INVALID MESSAGE LENGTH IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The length of the received message is not valid. This code is intended for programs, that use the ML byte to evaluate the data in the message. A message length, that is otherwise outside the valid range, is detected by OS. D1 - Received message length (ML) D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:34 CODE=34H INVALID SIGNAL NUMBER IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The signal number (SN) in the message was not valid. D1 - Received signal number (SN) D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:34,2 CODE=34H INVALID SIGNAL NUMBER IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The signal number (SN) in the message was not valid. D1 - Received signal number (SN) D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:35 CODE=35H INVALID CARD NUMBER IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The card number in the message was not valid. D1 - Received card position D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:35,2 CODE=35H INVALID CARD NUMBER IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The card number in the message was not valid. D1 - Received card position D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:36 CODE=36H INVALID INDIVID NUMBER IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The individual number, used in the message, was not valid. D1 - Received individual number (IND) D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:36,2 CODE=36H INVALID INDIVID NUMBER IN MESSAGE. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The individual number, used in the message, was not valid. D1 - Received individual number (IND) D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:37 CODE=37H MESSAGE TO NON-INSTALLED CARD/INDIVIDUAL. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER A message has been received to a card or individual that is not correctly initiated. The EEPROM data is not valid or there has not been sufficient RAM available. D1 - Received card position D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:37,2 CODE=37H MESSAGE TO NON-INSTALLED CARD/INDIVIDUAL. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER A message has been received to a card or individual that is not correctly initiated. The EEPROM data is not valid or there has not been sufficient RAM available. D1 - Received card position D2 - Received INFCODE D3 - Received SUBCODE D4 - Received DATA+1 If 'OS.WARNING code,DY' is not used, data D3 and D4 are supplied by OS from the ME-register. #CODE:38 CODE=38H DIRECTORY NUMBER ERROR. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The directory number is not defined. D1 - Directory number, high byte D2 - Directory number, low byte D3 - Undefined D4 - Undefined #CODE:39 CODE=39H NO ANSWER. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER Timeout on waiting for answer. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:3A CODE=3AH ABORTED PROCESS. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The process was aborted for a non specified reason. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:3B CODE=3BH ABORTED INIT. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER Init was aborted for a non specified reason. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:3C CODE=3CH INVALID ADDRESS. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER A list offset is pointing outside the list. D1 - Offset, high byte D2 - Offset, low byte D3 - Undefined D4 - Undefined #CODE:3D CODE=3DH INVALID PARAMETER. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The value of the input parameter is not valid. D1 - Pointer to the value, high byte D2 - Value or pointer to the value, low byte D3 - Undefined D4 - Undefined #CODE:3E CODE=3EH CALLED ROUTINE NOT READY. Default definition : ERROR Used by block : ALL Category : DESIGNER The called routine is not ready yet. This code is defined for the development phase only. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:3F CODE=3FH UNDEFINED ERROR. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER This code can be used, when no other code is appropriate. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:40 CODE=40H INVALID IDENTITY. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The ID code is invalid. D1 - Invalid data D2 - Invalid type 00H ... Invalid type is ST 01H ... Invalid type is SN 02H ... Invalid type is CARD 03H ... Invalid type is IND D3 - Undefined D4 - Undefined #CODE:41 CODE=41H INVALID INSTALLATION OF CARD. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The addressed card has an error in the installation (see also the group W.AMxxx). D1 - D2 - D3 - Undefined D4 - Undefined #CODE:42 CODE=42H INVALID PROCESS. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The process number is not valid or the process does not exist (see also the group W.AMxxx). D1 - D2 - D3 - Undefined D4 - Undefined #CODE:43 CODE=43H INVALID MESSAGE DATA. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The data in the message was not valid or not expected. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:44 CODE=44H UNEXPECTED NAK FROM E2. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER This code is used to inform OM about a NAK from the E2 handler. D1 - D2 - Error code from E2 (W = a warning is also done by the E2 handler) 01H ... Write fail - error at verification reading (W). 02H ... The input queue to the E2-handler is full (W) or a needed additional OS-buffer is not available. 04H ... The record number is above the limit (W). 05H ... No E2-record with the specified record number found. 06H ... An identical identity code has been found (E2BASSZ). 07H ... A specified E2 base area was not found. 08H ... No free E2 memory (E2BASSZ or E2RECSZ). 09H ... An identical directory number has been found (E2BASSZ). 0AH ... The base areas have different types (E2BASSWAP). 0BH ... Init aborted, E2 not available (W). 0CH ... Illegal parameter(s) found (E2RD or E2WR) (W). 0DH ... No space for more E2 base records. D3 - Undefined D4 - Undefined #CODE:45 CODE=45H VMU REFERENCE ERROR. Default definition : ERROR Used by block : ALL Category : DESIGNER A reference error in a message to a VMU has been detected by the VMU. The error is indicated in the answer from the VMU. The warning is intended for MG, AN, IN blocks. D1 - D2 - VMU card D3 - Undefined D4 - Undefined #CODE:46 CODE=46H UNEXPECTED NAK RECEIVED. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER A NAK has been received. This should normally not happen in the current situation. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:47,2 CODE=47H INVALID A-DIRECTORY NUMBER. Default definition : ERROR Used by block : ALL Category : DESIGNER The callers public directory number (a-directory number) was considered invalid. Check the programming of the exchange directory number. Check the programming of the callers directory number. D1 - D2 - Type of directory number 00H ... The exchange directory number is not defined. 01H ... Invalid caller directory number. 02H ... Invalid number length. D3 - Undefined D4 - Undefined Recommended action: Check the programming of the exchange directory number. Check the programming of the callers directory number. #CODE:47,8 CODE=47H INVALID A-DIRECTORY NUMBER. Default definition : ERROR Used by block : ALL Category : DESIGNER The callers public directory number (a-directory number) was considered invalid. D1 - D2 - Type of directory number 00H ... Invalid public number group. 01H ... Invalid caller directory number. 02H ... DIR.NONUM has been given as input data and no public number digits are programmed (no number to be returned) or a general error. D3 - Undefined D4 - Undefined Recommended action: Check the programming of the exchange directory number. Check the programming of the callers directory number. #CODE:48,1 CODE=48H WARNING ON PURPOSE. Default definition : UNDEFINED Used by block : ALL Category : DESIGNER This code is used, when a warning is caused intentionally by some manual user action in order to create a tracelog, etc. D1 - Directory number of own party, high byte D2 - Directory number of own party, low byte D3 - Directory number of connected party, high byte D4 - Directory number of connected party, low byte #CODE:48,4 CODE=48H MANUAL LOGGING. Default definition : UNDEFINED Used by block : ALL Category : DESIGNER This code is used, when a warning is caused intentionally by some manual user action in order to create a tracelog, etc. D1 - Directory number of own party, high byte D2 - Directory number of own party, low byte D3 - Directory number of connected party, high byte D4 - Directory number of connected party, low byte #CODE:49,1 CODE=49H BUFFER ERROR. Default definition : ERROR Used by block : RP Category : DESIGNER Buffer error. D1 - Type of buffer error D2 - Additional data 00H ... Trying to use a released bufer. Block ID (ST) 01H ... Trying to send a released buffer. Block ID (ST) 02H ... Number of free buffers below limit. 0 03H ... Number of buffers out of control from 0 OS below limit. D3 - Undefined D4 - Undefined #CODE:49,10 CODE=49H BUFFER ERROR. Default definition : ERROR Used by block : RP Category : DESIGNER Buffer error. D1 - Type of buffer error D2 - Additional data 00H ... Trying to use a released bufer. Block ID (ST) 01H ... Trying to send a released buffer. Block ID (ST) 02H ... Number of free buffers below limit. 0 03H ... Number of buffers out of control from 0 OS below limit. Some special definitions have been introduced for the CPU-D4 central processor board. 00H ... Work buffer troubles V.24 port number 01H ... Work buffer troubles V.24 port number 02H ... Work buffer troubles V.24 port number 04H ... Signal buffer watermark V.24 port number 05H ... Signal buffer watermark V.24 port number 07H ... Signal buffer watermark V.24 port number 08H ... Work buffer watermark V.24 port number D3 - Undefined D4 - Undefined #CODE:4A,1 CODE=4AH RP TIMER ERROR. Default definition : ERROR Used by block : RP Category : DESIGNER An error in the timer number of function calls to timers has been detected. D1 - Specified timer number D2 - Block ID (ST) D3 - Undefined D4 - Undefined #CODE:4B,1 CODE=4BH INVALID SIGNALTYPE IN RP MESSAGE. Default definition : ERROR Used by block : RP Category : DESIGNER The signal type (ST) in the message was not valid. D1 - Received identity D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:4C,1 CODE=4CH RP SERIAL COMMUNICATION ERROR. Default definition : ERROR Used by block : RP Category : MAINTENANCE A transmit or receive error has been detected by a RP. D1 - 0 D2 - Type of error Bit 0 ... Missing a part of a message Bit 1 ... Too long message received Bit 2 ... Error in the ML in a buffer for the transmission of an info message. Bit 3 ... Unexpected events in state Bit 4 ... Undefined DFD Bit 5 ... Receive error during transmit e.g. receive fault when waiting for ACK/NAK. Bit 6 ... 0 Bit 7 ... 0 D3 - Undefined D4 - Undefined #CODE:4D,0 CODE=4DH RP POWER SUPPLY ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : RP Category : MAINTENANCE Some cards perform a power supply test after the CARD CONTROL (BLOCKED/NORMAL) message has been received at startup. This warning is sent, if an invalid voltage level is detected. ELUA10: D1 - Supervision of -5V 00H ... No error or no data available for -5V 01H - FFH ... Current value (0.043 * D1 - 6.05) D2 - Supervision of -38V 00H ... No error or no data available for -38V 01H - FFH ... Current value (0.181 * D2 - 41.3) #CODE:4D,1 CODE=4DH ANALOG PROBE LIMIT EXCEEDED. Default defintion : ALARM+EXTERN+ACTIVE Used by block : RP Category : MAINTENANCE An A/D converter value is out of limits or back inside the limits, depending on how the current threshold has been set. By default, warnings are generated only, when an A/D converter of type supervision detects an out-of-limits value. D1 - D2 - Type of A/D converter as defined in ADFUNCTION message. D3 - Current value of given A/D converter, including controlbits, high byte Bit 7 ... Sign bit (0 indicates a positive value) Bit 6 - 5 ... 00 Not valid ... 01 Value back within limits ... 10 Value out of high limits ... 11 Value out of low limits Bit 4 ... Hundreds (0 or 1) Bit 3 - 0 ... Tens (0 - 9) D4 - Current value of given A/D converter, including controlbits, low byte Bit 7 - 4 ... Ones (0 - 9) Bit 3 - 0 ... Tenth (0 - 9) #CODE:4E CODE=4EH BTU ILLEGAL LOOP DETECTED. Default definition : ERROR Used by block : BTU-A, BTU-C Category : MAINTENANCE A faulty loop has been detected by a BTU board. The fault may be caused by a short circuit or a foreign voltage in the cabling to the BTU board. D1 - Individual number D2 - Loop testpoint value 01H ... Loop from LA to LB detected. 02H ... Loop from LB to LA detected D3 - Undefined D4 - Undefined #CODE:4F,0 CODE=4FH BTU ILLEGAL RELAY STATE. Default definition : ERROR Used by block : BTU Category : DESIGNER An illegal relay state on a BTU board has been detected and corrected. D1 - Relay state D2 - Individual number D3 - Undefined D4 - Undefined #CODE:4F,1 CODE=4FH RP ILLEGAL HARDWARE STATE. Default definition : ERROR Used by block : BTU, ELU-A Category : DESIGNER The hardware state is checked, when a trunk or extension line is idle. This warning is sent, when an illegal state is detected. The illegal state is corrected. D1 - Individual number D2 - Illegal state D3 - Undefined D4 - Undefined #CODE:4F,11 CODE=4FH RP ILLEGAL HARDWARE STATE. Default definition : ERROR Used by block : BTU, CPU-D4, ELU-A Category : DESIGNER The hardware state is checked, when a trunk or extension line is idle. This warning is sent, when an illegal state is detected. The illegal state is corrected. D1 - Individual number D2 - Illegal state D3 - Undefined D4 - Undefined #CODE:50 CODE=50H NO TR-PROCESS FOUND. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The process, specified in the message by the parameter SN, was not found. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:50,2 CODE=50H NO TR-PROCESS FOUND. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The process, specified in the message by the parameter SN, was not found. D1 - Process or device state D2 - Message code D3 - Card position D4 - Individual number of BTU #CODE:51 CODE=51H INVALID MESSAGE IN TR-STATE. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER An unexpected message has been received in the current state. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:51,2 CODE=51H NO ANSWER. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER Timeout on waiting for answer. D1 - Process or device state D2 - Message code D3 - Card position D4 - Individual number of BTU #CODE:52 CODE=52H INVALID BTU CATEGORY. Default definition : ALARM+EXTERN+ACTIVE Used by block : TR Category : MAINTENANCE The given BTU category is not yet prepared. This warning indicates a programming error. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined Recommended action: Check the programming of the external lines. #CODE:53 CODE=53H TRIG TRACE LOG. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER This code is used to trig the trace-function. No specific error situation is indicated. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:53,2 CODE=53H TRIG TRACE LOG. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER This code is used to trig the trace-function. No specific error situation is indicated. D1 - Process or device state D2 - Message code D3 - SUBCODE D4 - DATA+1 #CODE:54 CODE=54H DIGIT RECEIVE ERROR. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER Too many digits have been received. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:54,2 CODE=54H The warning code 54H is no longer used. #CODE:54,5 CODE=54H TRUNK BLOCKED. Default definition : ERROR Used by block : TR Category : MAINTENANCE The line to the connected exchange has been blocked from the cooperating exchange. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:55 CODE=55H EXTERNAL LINE DISTURBANCE. Default definition : ALARM+EXTERN+ACTIVE Used by block : TR Category : MAINTENANCE An external line has been disturbance marked. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined Recommended action: Check the line to the public exchange (PE). Check feeding and polarity, transmission, dial-tone from PE, etc. #CODE:56 CODE=56H BTU ALREADY CONNECTED. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The flag 'BTU connected' is already set. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:56,2 CODE=56H BTU ALREADY CONNECTED. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The flag 'BTU connected' is already set. D1 - Process or device state D2 - Message code D3 - Card position D4 - Individual number of BTU #CODE:57,0 CODE=57H CMU ALREADY CONNECTED. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The flag 'CMU connected' is already set. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:57,1 CODE=57H CALL METERING ALREADY SEIZED. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The flag 'CM seized' is already set. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:57,2 CODE=57H CALL METERING ALREADY SEIZED. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The flag 'CM seized' is already set. D1 - Process or device state D2 - Message code D3 - Card position D4 - Individual number of BTU #CODE:58 CODE=58H PCM CHANNEL ERROR. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER An error in the PCM channel handling has been detected. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:59 CODE=59H INVALID PROCESS REASON. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER An irrelevant 'process reason' has been detected in the received message. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:59,2 CODE=59H INVALID PROCESS REASON. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER An irrelevant 'process reason' has been detected in the received message. D1 - Process or device state D2 - Message code D3 - Card position D4 - Individual number of BTU #CODE:5A CODE=5AH INVALID PROCESS RELEASE. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The given process was not found in the BTU's process chain at release. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:5A,2 CODE=5AH INVALID PROCESS RELEASE. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The given process was not found in the BTU's process chain at release. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:5B CODE=5BH SEIZCALL ERROR. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER No message buffer left for the 1st or 2nd party. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:5C CODE=5CH SEIZNAK ERROR. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER An invalid SEIZNAK reason has been detected. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:5C,2 CODE=5C SEIZNAK ERROR. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER An invalid SEIZNAK reason has been detected. D1 - Process or device state D2 - Message code D3 - Card position D4 - Individual number of BTU #CODE:5D CODE=5DH NO TR-BUFFER. Default definition : ERROR Used by block : TR Category : DESIGNER The buffer already exists, no buffer has been available or it was not allowed to keep the buffer. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:5E CODE=5EH TR-BUFFER ERROR. Default definition : ERROR Used by block : TR Category : DESIGNER The message buffer is missing, when message sending is attempted. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:5F CODE=5FH TR-PROCESS STATE MISSING. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The old 'process state' was missing, when reloading the old value. D1 - Process or device state D2 - Message code D3 - Undefined D4 - Undefined #CODE:5F,2 CODE=5FH TR-PROCESS STATE MISSING. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The old 'process state' was missing, when reloading the old value. D1 - Process or device state D2 - Message code D3 - SUBCODE D4 - DATA+1 #CODE:60 CODE=60H TIMER REQUEST ERROR. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The program tried to request a timer, when no process was connected. D1 - Card position D2 - Individual number of BTU D3 - Undefined D4 - Undefined #CODE:60,2 CODE=60H TIMER REQUEST ERROR. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The program tried to request a timer, when no process was connected. D1 - Process or device state D2 - Message code D3 - Card position D4 - Individual number of BTU #CODE:61 CODE=61H TRUNK LINE ERROR. Default definition : ERROR Used by block : TR Category : MAINTENANCE The line to the connected exchange has a faulty/no polarity (line guard). D1 - Card position D2 - Individual number D3 - Undefined D4 - Undefined Recommended action: Check the line polarity on the trunk(s). #CODE:62,0 CODE=62H TRUNK LINE WITHOUT CMU. Default definition : ERROR Used by block : TR Category : MAINTENANCE A line to the connected exchange has been used without a working CMU card. D1 - Card position D2 - Individual number D3 - Undefined D4 - Undefined #CODE:62,1 CODE=62H TRUNK LINE WITHOUT CALL METERING. Default definition : ERROR Used by block : TR Category : MAINTENANCE A line to the connected exchange has been used without a CM board on the trunk card, or the CM board did not answer. D1 - Card position D2 - Individual number D3 - Undefined D4 - Undefined #CODE:63 CODE=63H INVALID SIGNAL FROM BTU. Default definition : ERROR+TRIG Used by block : TR Category : DESIGNER The subcode, received in the BTCSIGNAL message, is not valid for the current state. D1 - Current state D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:63,2 CODE=63H The warning code 63H is no longer used. #CODE:64,1 CODE=64H INVALID PARAMETER(S) TO BTU. Default definition : ERROR+TRIG Used by block : TR Category : MAINTENANCE The BTU did not accept the E2 data, sent to it. If this happens during a coldstart, the BTU will use its own default parameters. If it happens during programming, no change are made to the current parameters. The second parameter contains information about the not accepted data at the parameter updating to the RP. The RP replies with the internal number value for the parameter. D1 - Subcode for the actual parameter updating code. D2 - Internal parameter number value for not accepted data. 01H ... Signal interface scheme, scheme is not available on the RP 02H ... Dial tone level, level out of range 03H ... Disconnection tone level, level out of range 04H ... Filter coefficient, filter coefficient not available 05H ... Relative send level, level out of range 06H ... Relative receive level, level out of range 07H ... Network / User, level out of range D3 - Card position D4 - Individual number of BTU Recommended action: Check revision / version of the RP (and / or BTU). #CODE:65 CODE=65H CTI IO ERROR. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : CT Category : MAINTENANCE Some error or timeout in the IO handling, detected by the CTI programs. D1 - D2 - D3 - Undefined D4 - Undefined Recommended action: Verify the connection of the external (peripheral) equipment and the programming of the relevant IO-channel. #CODE:65,10 CODE=65H APPLICATION IO ERROR. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : CD, CT Category : MAINTENANCE Some error or timeout in the IO handling, detected by an application handling software block, like CD or CT. D1 - D2 - D3 - Undefined D4 - Undefined Recommended action: Verify the connection of the external (peripheral) equipment and the programming of the relevant IO-channel. #CODE:66 CODE=66H CIL IO ERROR CHANNEL 0. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : CL Category : MAINTENANCE Some error or timeout in the IO handling, detected by the CIL programs for channel number 0. D1 - D2 - D3 - Undefined D4 - Undefined Recommended action: Verify the connection of the external (peripheral) equipment and the programming of the relevant IO-channel. #CODE:67 CODE=67H CIL IO ERROR CHANNEL 1. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : CL Category : MAINTENANCE Some error or timeout in the IO handling, detected by the CIL programs for channel number 1. D1 - D2 - D3 - Undefined D4 - Undefined Recommended action: Verify the connection of the external (peripheral) equipment and the programming of the relevant IO-channel. #CODE:68 CODE=68H INVALID MESSAGE IN CL-STATE. Default definition : ERROR Used by block : CL Category : DESIGNER An unexpected message has been received in the current state. D1 - Process state D2 - Message code D3 - Undefined D4 - Undefined #CODE:6A,2 CODE=6AH INVALID MESSAGE IN TS-STATE. Default definition : ERROR Used by block : TS Category : DESIGNER An unexpected message has been received in the current state. D1 - Process state D2 - Message code D3 - Undefined D4 - Undefined #CODE:6B CODE=6BH PC-BLOCK IO ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : PC Category : DESIGNER Some error has been detected in the IO handling of the PC-block. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:6D CODE=6DH VMU MEMORY ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : VM Category : MAINTENANCE An error has been found in the data in the VMU memory. This can be a program or a battery malfunction. D1 - D2 - Card position D3 - Undefined D4 - Undefined #CODE:6F CODE=6FH IO ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : EU Category : DESIGNER Some error has been detected in IO handling for V24 or MODEM port. D1 - Type of error. 01H ... I/O port locked after repeated errors. 02H ... Message lost (IOMESS used by local or remote O&M) 03H ... Message timeout (usage as above) 04H ... Timer request failed for no apparent reason. D2 - Card position D3 - Undefined D4 - Undefined #CODE:6F,11 CODE=6FH IO ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : EU Category : DESIGNER Some error has been detected in IO handling for V24 or MODEM port. D1 - Type of error. 01H ... I/O port locked after repeated errors. 02H ... Message lost (IOMESS used by local or remote O&M) 03H ... Message timeout (usage as above) 04H ... Timer request failed for no apparent reason. 05H ... Invalid Multichannel command received. D2 - Card position D3 - Undefined D4 - Undefined #CODE:70,0 CODE=70H NO EXU-CARD FOUND. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : EU Category : MAINTENANCE This warning code is used, when the operative system has been unable to find any EXU-card in the system. One EXU-card must exist in all ASB 150 systems. The fault reason can be : - The board is missing. - The board exists in the system, but has not been activated. - The existing board is faulty. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:70,1 CODE=70H The warning code 70H is not used in ASB 150 02. #CODE:71 CODE=71H INDIVIDUAL MEMORY NOT SUFFICIENT. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : SU Category : MAINTENANCE SU could not allocate enough individual data memory. At start-up, SU tries to allocate data memory for all cards in the system, starting at card position 0. This warning is used, if not enough memory remains to satisfy the request of memory for the card. D1 - D2 - Card position, where the request failed D3 - Undefined D4 - Undefined Recommended action: The only cure is to remove some card from the system. #CODE:72,0 CODE=72H INVALID PARAMETER AT STARTUP. Default definition : ERROR Used by block : SU Category : DESIGNER An invalid parameter value has been found by SU. D2 - Type of error D1 - Additional data 00H ... Not defined. 01H ... Default data length error for Block ID (ST) the E2BASE. 02H ... Card table access error. Given card position 03H ... ID error on answer from the Received card position E2-handler. D3 - Undefined D4 - Undefined #CODE:72,1 CODE=72H INVALID PARAMETER AT STARTUP. Default definition : ERROR Used by block : SU Category : DESIGNER An invalid parameter value has been found by SU. D2 - Type of error D1 - Additional data 00H ... Not defined. 01H ... Default data length error for Block ID (ST) the E2BASE. 02H ... Card table access error. Given card position 03H ... ID error on answer from the Received card position E2-handler. 04H ... Highest reported individual Reporting card position number too high. 05H ... The data length for the Individual type individual RAM record in the REPORT table is higher than 125 bytes. D3 - Undefined D4 - Undefined #CODE:73 CODE=73H CARD PLACEMENT ERROR. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : SU Category : MAINTENANCE Some card position in the system has E2-data stored, that does not match the actual card type. D1 - D2 - Lowest card position, that did not match D3 - Undefined D4 - Undefined Recommended action: Use RASC (hardware/software menu) to check, which board positions cause the problem and evaluate the type of fault for the respective board position. If the relevant board position (placing) is intentional, use the 'update board position' function, otherwise the relevant boards are to be placed in their correct positions. #CODE:74 CODE=74H NO DEFAULT E2DATA REPORTED. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : SU Category : MAINTENANCE SU did not find default data, corresponding to this individual type. Some cardhandling CP program is possibly missing. D1 - Card position D2 - Version / type of individual from the CARDREP message D3 - Undefined D4 - Undefined Recommended action: Verify that the software on the CPU-board has the correct version. #CODE:75 CODE=75H INVALID DATA IN RP-MESSAGE. Default definition : ERROR Used by block : RP Category : DESIGNER Some data in a message was not accepted by the RP program. D1 - Offset in the message 00H ... DATA 01H ... DATA+1 ... D2 - Received INFCODE D3 - Undefined D4 - Undefined #CODE:76,0 CODE=76H CMU INSUFFICIENT MEMORY. Default definition : ALARM+EXTERN+ACTIVE Used by block : CMU Category : MAINTENANCE It was impossible to assign a call metering counter to an extension, because there is no free counter on a CMU-board. A counter is created, when an extension initiates the first metering call and is removed, when the extension counter is reset. The number of counters is much greater than the total number of extensions, for which reason this fault normally only can occur, when directory numbers of extensions are changed and the reset of the counters for the old directory numbers is forgotten. D1 - Extension number, high byte D2 - Extension number, low byte D3 - Undefined D4 - Undefined Recommended action: Reset the call metering counters for all unused extension numbers. #CODE:76,1 CODE=76H RP DSLAC ERROR. Default definition : ERROR Used by block : BTU, ELU-A Category : DESIGNER The DSLAC is tested at restart and during traffic, by reading back written data. A warning message is sent in case that read data is not the same as the written data. D1 - Individual number D2 - Faulty DSLAC command D3 - Undefined D4 - Undefined #CODE:77,0 CODE=77H CMU MEMORY ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : CMU Category : MAINTENANCE Call metering counters on a board are used by those trunks with count- ers that exist on the board and also by those extensions with counters that have initiated external calls via the board. The fault code means that all call metering counters on the relevant board have been reset. This affects trunks on the board and those extensions, who have had call metering counters on the board. The reason for reset of the counters is that the check data, used for the counters, was incorrect and consequently the contents of all counters on the board was deemed to be unreliable. Note that this fault code is normally generated the first time, the board is activated. D1 - D2 - Card position D3 - Undefined D4 - Undefined Recommended action: If the fault also occurs on occasions other than the very first start of the board, a check is to be made, to verify that the battery on the CMU-board is connected. If this is the case the battery is to be replaced. #CODE:77,1 CODE=77H The warning code 77H is no longer used. #CODE:77,5 CODE=77H BTUDP WARNING. Default definition : ERROR Used by block : BTU-DP Category : DESIGNER This warning represents an unique warning code for the BTU-DP (ISDN primary rate access). The warning is used as help for the BTUDP program designers. D1 - BTU-DP defined function ID D2 - BTU-DP defined warning type D3 - User-defined data D4 - User-defined data #CODE:77,13 CODE=77H CARD TYPE WARNING. Default definition : ERROR Used by block : BTU-B, BTU-DP, MFU Category : DESIGNER This warning represents a warning code for the ISDN interface boards and also the MFU board. The warning is used as help for the responsible designer. Check the board position to define the card type. D1 - Function ID D2 - Warning type D3 - User-defined data D4 - User-defined data #CODE:78 CODE=78H RP STATE ERROR. Default definition : ERROR Used by block : RP Category : DESIGNER The specified state could not be found by the RP program. D1 - D2 - State D3 - Undefined D4 - Undefined #CODE:79 CODE=79H LOSS OF I/O PORT MESSAGE. Default definition : ERROR+TRIG Used by block : RP Category : DESIGNER The code is used by RP's with ports. A message sequence error has been detected in an output message flow, using IOMESS messages, or there are no free transmit buffers. A complete message from the CPU to the current I/O-port is lost. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:7A CODE=7AH INVALID PCM CHANNEL USED. Default definition : ERROR+TRIG Used by block : RP Category : DESIGNER An invalid PCM channel number was detected by the RP. D1 - D2 - Invalid PCM channel D3 - Undefined D4 - Undefined #CODE:7B CODE=7BH INVALID SENDER OF MESSAGE TO MP. Default definition : ERROR Used by block : MP Category : DESIGNER This code is used in the following cases : - A MPCON message has been received, which was not sent from OPERATOR, CONFERENCE or BREAK-IN block. - A MPCON message has been received, requesting more than four PCM channels, and the sender was not the CONFERENCE block. D1 - Number of PCM channels requested D2 - Block ID (ST) of the sender of the MPCON message D3 - Undefined D4 - Undefined #CODE:7C,0 CODE=7CH BTU RESOURCE LIMIT EXCEEDED. Default definition : ERROR Used by block : BTU Category : DESIGNER There were not enough timers or buffers available for the RP on the BTU card. D1 - Error address, high byte D2 - Error address, low byte D3 - Undefined D4 - Undefined #CODE:7C,1 CODE=7CH RP RESOURCE LIMIT NEARLY EXCEEDED. Default definition : ERROR Used by block : BTU, ELU-A Category : DESIGNER The warning is sent, when only four of the limited resources of either buffers, timers or digit-storage is available. D1 - Individual number or 0 D2 - Type of resources 00H ... receive buffer limit 01H ... External send buffer limit 02H ... Internal buffer limit 03H ... Timer limit 04H ... Digit position limit D3 - Undefined D4 - Undefined #CODE:7D CODE=7DH NO ROOM IN NUMBER SEARCHTABLE. Default definition : ERROR Used by block : MG Category : DESIGNER There was no room in the number searchtable. D1 - D2 - Current state D3 - Undefined D4 - Undefined #CODE:7E CODE=7EH NO MENUTEXT FOUND. Default definition : ERROR Used by block : MG Category : DESIGNER The display menutext is missing for the current state. D1 - D2 - Current state D3 - Undefined D4 - Undefined #CODE:7F CODE=7FH MESSAGETEXT ERASE ERROR. Default definition : ERROR Used by block : MG Category : DESIGNER An error has been detected, when erasing a message. The flag field specifies, which part of the erase process failed. D1 - D2 - Flag field D3 - Undefined D4 - Undefined #CODE:80 CODE=80H EXTENSION FIFO IS FULL. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER There were not enough free bytes in the FIFO. The store command has been ignored, i.e. no byte(s) have been stored. D1 - D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:81 CODE=81H INVALID CONCTRL-MESSAGE. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER The new state, defined in the received CONCTRL message, is not defined for the current state. D1 - Received state, which is not defined. D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:82 CODE=82H PROCESS RETURN ERROR. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER An attempt to return a process from one state to another has failed, because the return parameter was not defined. D1 - Process state for the process, which has been failed to return. D2 - Current process state. This process normally has ordered the return event. D3 - Undefined D4 - Undefined #CODE:83 CODE=83H EK-ERROR. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER The current EK-state was not compared correctly to the current process / instrument state, e.g. there is no free EK, but the instrument state was indicating that all EK's should be free. D1 - D2 - Current process / instrument state. D3 - Undefined D4 - Undefined #CODE:84 CODE=84H NO IND-DATA RECEIVED ON REQUEST. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER An INDDATAREQ message was answered with an empty INDDATAANSW message. Normally the INDDATAREQ / INDDATAANSW sequence is used in the display handler, when the display should be updated. D1 - Current LCD-state. D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:85 CODE=85H FUNCTIONKEY CAN NOT BE HANDLED. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER A programmable key with a defined function was detected, but the function was not defined for the current state. D1 - The function, which cannot be handled. D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:86 CODE=86H INVALID PROCESS REASON DETECTED. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER The reason for creating a new process was not defined as a valid reason. D1 - The reason, which is not defined. D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:87 CODE=87H NO PROCESS CREATED. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER An attempt to create a new process failed, because of resources missing, reason not specified correctly, etc. D1 - D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:88 CODE=88H UNDEFINED RINGSIGNAL. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER The terminator head, which indirectly indicates which ring signal should be used towards an extension, was invalid. D1 - The invalid terminator head. D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:89 CODE=89H INVALID SUBCODE. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER The detected sub-function was not defined for the current INFCODE. D1 - Current INFCODE D2 - Current SUBCODE. D3 - Undefined D4 - Undefined #CODE:8A CODE=8AH WRONG INSTRUMENT TYPE. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER The detected instrument type could not handle the requested function. D1 - D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:8B CODE=8BH ILLEGAL ATTEMPT TO STEP LCD-STATE. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER The step-LCD-state order was ignored, because the requested step-execution was impossible to execute. D1 - Current display state. D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:8C CODE=8CH NO ANSWER IN TIME. Default definition : ERROR+TRIG Used by block : EX Category : DESIGNER An expected answer has not been received within the specified time. D1 - D2 - Current process state. D3 - Undefined D4 - Undefined #CODE:8D CODE=8DH TAU PARAMETERS MISSING. Default definition : ALARM+EXTERN+ACTIVE Used by block : EX Category : MAINTENANCE The extension has been programmed as a data extension, but the record for TAU parameters has not been created. This error can be corrected by reprogramming. D1 - Card position for the extension D2 - Individual number for the extension. D3 - Undefined D4 - Undefined Recommended action: First, program the extension as a non-data extension (see command 0130) and then program it as a data extension again. #CODE:8E CODE=8EH INSTRUMENT TYPE ERROR. Default definition : ERROR Used by block : EX Category : MAINTENANCE A faulty instrument type has been signalled from ELUD, i.e. the instrument type has changed, but the instrument has not been unplugged in between. This warning code is only sent on the first occurrence after a new instrument has been plugged in. The warning indicates a signalling problem between the instrument and ELUD. D1 - Card position for the extension D2 - Individual number for the extension. D3 - Undefined D4 - Undefined Recommended action: Occasional warnings of this type can occur, when a cable is run through environments, in which electrical disturbances occur and / or where the lines to the telephones are long. In the case of repeated faults, verify that the line from the PBX to the telephone is correctly installed, loose connections and loose screws can cause 'instrument type errors'. If the line is correct, but the fault persists, replace the telephone. If a new telephone displays the same symptom, replace the extension board. #CODE:8F,2 CODE=8FH EXTENSION LINE (DISTURBANCES) ERROR. Default definition : ERROR Used by block : EX Category : MAINTENANCE The signalling between the exchange and the telephone / equipment is not working properly. The reason could be a faulty telephone, faulty ELU-card, too long telephone lines, disturbances in the communication, etc. Note that a real line fault, caused by the fact that a telephone is unplugged, does NOT cause a warning. This warning is only used, as mentioned earlier, when the signalling is more or less OK, but not good enough. D1 - Card position for the extension D2 - Individual number for the extension. D3 - Main reason for the warning, see the LINERR-message for details. D4 - Detailed reason for the warning, see the LINERR-message for details. Recommended action: If the error occurs too often, try the following steps : - Replace the telephone. - Check the installation for loose connections, etc. - Replace the ELU-board indicated by data in D1 (hex-value). - Try with shorter lines, to see if the line length affects the problem. #CODE:90 CODE=90H OM INTERNAL ERROR. Default definition : ERROR Used by block : OM Category : DESIGNER This warning is used by the OM block to log errors that occur within the own block. The type of error is not considered to merit an unique error code. D1 - D2 - Type of error D3 - Undefined D4 - Undefined #CODE:91,0 CODE=91H PATCH ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : OM Category : MAINTENANCE An error has been found in the patch program in the E2-area. No patch will be activated at startup. D1 - D2 - Type of error 00H ... Erroneous or incomplete patch. 01H ... Checksum error. D3 - Undefined D4 - Undefined #CODE:91,1 CODE=91H EXTENDED TRACELOG WARNING. Default definition : ALARM Used by block : OM Category : DESIGNER This warning is not caused by a specific error, but is used as an optional signal in the EXTENDED TRACE mechanism to show that the selected event has occurred. The warning data differs for the warning trace and the state trace. Warning trace D1 - Data from the original warning D2 - Data from the original warning D3 - Data from the original warning D4 - Data from the original warning State trace D1 - 0 D2 - 0 D3 - Undefined D4 - Undefined #CODE:92,0 CODE=92H MAP PATCH-IDENTITY ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : OM Category : MAINTENANCE The identity of the specified map is not equal to the identity of the patch. The patches for this map will not be activated. Patches for other maps are not affected. D1 - D2 - Map number D3 - Undefined D4 - Undefined #CODE:92,1 CODE=92H The warning code 92H is not used in ASB 150 02. #CODE:93 CODE=93H FIRST E2 READ/WRITE FAILED. Default definition : ERROR Used by block : OM Category : DESIGNER A write to the E2 area has failed at the first attempt. Timeout or E2NAK has been received. A second attempt will be made in most cases. D1 - D2 - Map number of E2 memory D3 - Undefined D4 - Undefined #CODE:94 CODE=94H SECOND E2 READ/WRITE FAILED. Default definition : ALARM+EXTERN+ACTIVE Used by block : OM Category : MAINTENANCE A write to the E2 area has failed at the second attempt. Timeout or E2NAK has been received. No more attempts will be made. D1 - D2 - Map number of E2 memory D3 - Undefined D4 - Undefined Recommended action: If this fault is repeated, the CPU board should be replaced. As an alternative, the identified EEPROM-circuit can be replaced. The system must be reprogrammed, preferrable from a backup. #CODE:95 CODE=95H INVALID E2 DATA. Default definition : ERROR Used by block : OM Category : DESIGNER A non-recoverable error has been found in the E2 data. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:96 CODE=96H INVALID COMMAND NUMBER. Default definition : ERROR Used by block : OM Category : DESIGNER An invalid command number has been received. D1 - Command number (group) D2 - Command number D3 - Undefined D4 - Undefined #CODE:97 CODE=97H CARD SUPERVISION FAILURE. Default definition : STOP Used by block : OM Category : MAINTENANCE The supervision facility has detected an error. If the error was 'no response from some card', the attempt to communicate with the card in question is repeated five times, before the warning is sent. D1 - 0 D2 - Card position D3 - Undefined D4 - Undefined #CODE:98 CODE=98H INVALID WARNING CODE RECEIVED. Default definition : ALARM+EXTERN+ACTIVE+TRIG Used by block : OM Category : DESIGNER An invalid (out of range) warning code has been received by the OM programs. The original warning message is not changed, except for the code value, which is changed to W.OMINVWCODE. D1 - Data from the original warning D2 - Data from the original warning D3 - Data from the original warning D4 - Data from the original warning #CODE:99 CODE=99H WARNING LOG FULL. Default definition : ALARM+INFO+NOPROG+EXTERN+ACTIVE Used by block : OM Category : MAINTENANCE This warning is used for the logs ERROR, ALARM and STOP. It is sent, when the number of free positions in the logarea becomes less or equal to the number specified by the constant OM.LOWALIM. The interpretation of the warning should be that the EEPROM logarea is becoming full. If this condition is allowed to continue, warning messages will be lost. Read the information in the logareas and reset the logs through command 7002. D1 - D2 - Type of logarea 01H ... ERROR logarea 02H ... ALARM logarea 03H ... STOP logarea D3 - Undefined D4 - Undefined #CODE:9A CODE=9AH BACKUP BATTERY USED. Default definition : INFO+NOPROG+EXTERN+ACTIVE Used by block : OM Category : MAINTENANCE The code is used, when a signal on the alarm input on the CPU card is detected. This input is used to notify the system, that the backup battery is currently being used. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:9B CODE=9BH CARD MISSING AFTER POWERUP. Default definition : STOP Used by block : OM Category : MAINTENANCE The code is used, when the supervision function found a missing card after power-up. Missing is defined as present in the E2 area, but does not report at start-up. This warning is sent only at the power-up restart. D1 - D2 - Card position for the first missing card D3 - Undefined D4 - Undefined #CODE:9C CODE=9CH HEARTBEAT FAILED. Default definition : ALARM Used by block : OM Category : MAINTENANCE The code is used, when the heartbeat function failed. D1 - Type of error 10H ... Timer request failed, no heartbeat sent. 11H ... Unable to seize port, no heartbeat sent 12H ... No connection, no heartbeat sent 13H ... No answer to heartbeat D2 - 0 D3 - Undefined D4 - Undefined #CODE:9D CODE=9DH ACTIVE ALARM FAILED. Default definition : ALARM Used by block : OM Category : MAINTENANCE The code is used by the active alarm function. D1 - Type of error 00H ... Used by the 'test call' function. 01H ... Sendlimit reached. Nothing more will be sent this day. 10H ... No timer received. The 'active' function will be disabled. No attempt to send this alarm has been made. 11H ... Unable to seize port, SEIZNAK received, nothing sent. 12H ... No connection, CONEND received, nothing sent. 13H ... No answer to alarm call, no CONRDY received. D2 - Number of alarms in EEPROM buffer (D1 = 01H) D3 - Undefined D4 - Undefined #CODE:9F,0 CODE=9FH TESTPATCH WARNING. Default definition : ERROR Used by block : ALL Category : DESIGNER The code is used in the testpatch function. D1 - Contents of A at time of warning D2 - Contents of B at time of warning D3 - Undefined D4 - Undefined #CODE:9F,1 CODE=9FH The warning code 9FH is not used in ASB 150 02. #CODE:A0 CODE=A0H SERIAL COMMUNICATION ERROR. Default definition : ERROR Used by block : SP Category : MAINTENANCE A transmit or receive error was detected by SP. D1 - Card position FFH ... Card position is unknown. D2 - Type of error Bit 0 ... NAK has been received Bit 1 ... No ACK/NAK has been received to a sent message Bit 2 ... RX-data line was not quiet, when a new message should be sent to a RP, or when a poll cycle should start, or when retransmission is requested from the RP. Bit 3 ... Framing error Bit 4 ... Overrun error Bit 5 ... Checksum error Bit 6 ... Message received after a poll does not match the address of the received poll-ACK. Bit 7 ... No complete message received in time. Bit 0 - 1 ... Message from CP to RP is probably lost. Bit 3 - 7 ... Message from RP to CP is always lost. D3 - Undefined D4 - Undefined #CODE:A1 CODE=A1H SERIAL COMMUNICATION POLLERROR. Default definition : ERROR Used by block : SP Category : MAINTENANCE A request to send has been received from a regional processor (the EIRQ line has been pulled low), but no transmit was done. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:A2 CODE=A2H COMMUNICATION ERROR OS-SP. Default definition : ERROR Used by block : SP Category : DESIGNER The command, received from CP, contained a CODE or PARAMETER, that is undefined. D1 - D2 - Received command D3 - Undefined D4 - Undefined #CODE:A3 CODE=A3H SP PROGRAM MEMORY ERROR. Default definition : ALARM+NOPROG+EXTERN+ACTIVE Used by block : SP Category : MAINTENANCE The serial communication processor (SP) on the CPU board has found a program memory checksum error. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:A4 CODE=A4H SP DUAL PORT RAM ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : SP Category : MAINTENANCE The serial communication processor (SP) on the CPU board has detected an error in the dual ported communication RAM. D1 - Address, high byte D2 - Address, low byte D3 - Undefined D4 - Undefined Recommended action: If the fault remains after restart, the CPU-board should be replaced. Alternatively the data memory, used as interface between SP and CP, can be replaced. #CODE:A5 CODE=A5H CS-MESSAGE BUFFER SEQUENCE ERROR. Default definition : ERROR Used by block : SP Category : DESIGNER The serial communication processor (SP) on the CPU board has received a CSMEEX command with a parameter, pointing out an unexpected message buffer number. CP shall send CSMEEX commands in consecutive message buffers. D1 - Expected buffer number D2 - Received buffer number D3 - Undefined D4 - Undefined #CODE:A6 CODE=A6H SC-MESSAGE BUFFER SEQUENCE ERROR. Default definition : ERROR Used by block : SP Category : DESIGNER The serial communication processor (SP) on the CPU board has received a CSMERY command with a parameter, pointing to an unexpected message buffer number. CP shall acknowledge SCMEEX commands in consecutive order. D1 - Expected buffer number D2 - Received buffer number D3 - Undefined D4 - Undefined #CODE:A7 CODE=A7H SP INTERNAL ERROR. Default definition : ERROR Used by block : SP Category : DESIGNER The serial communication processor (SP) on the CPU board has detected an error, that probably is a bug in the SP software. D1 - Address of error, high byte D2 - Address of error, low byte D3 - Undefined D4 - Undefined #CODE:A8 CODE=A8H E2-WRITE SEQUENCE ERROR. Default definition : ERROR Used by block : SP Category : DESIGNER The serial communication processor (SP) on the CPU board has detected an error in the E2-write sequence. D1 - D2 - Type of error 01H ... CP has written (indicated write complete (NMI)) without enabling E2-memory first. 02H ... CP has requested enabling of E2-write before earlier write was ready. 03H ... CP has requested enabling of E2 write, but no writing was done within 100 ms. D3 - Undefined D4 - Undefined #CODE:A9 CODE=A9H SC-MESSAGE BUFFER OVERWRITE. Default definition : ERROR Used by block : SP Category : DESIGNER The serial communication processor (SP) has not received a CSMERY for the next D$SCMx field to use, but all D$SCMx fields are not busy. This indicates, that CP has executed the D$SCMx fields in incorrect order or made some other error. In order not to 'loose' this D$SCMx field, SP overwrites it with a new message from RP. D1 - D2 - D$SCMx field number D3 - Undefined D4 - Undefined #CODE:AA CODE=AAH INVALID SP-STATUS. Default definition : ERROR Used by block : SP Category : DESIGNER This code indicates an internal error in the SP program. The warning indicates, that an internal or external command is received in an invalid state. D1 - Current state There are several state variables in SP. No exact definition is done. D2 - Type of command F0H ... Receiver interrupt F1H ... Transmitter interrupt D3 - Undefined D4 - Undefined #CODE:AB,10 CODE=ABH BATTERY BACKED-UP RAM HANDLER ERROR. Default definition : ERROR Used by block : OS Category : DESIGNER An error occurred within the handler for the battery backed-up RAM. D1 - Error code 01H ... Given pool ID is invalid 02H ... Not enough memory available. 03H ... Given size of record is too large. 04H ... Not an user of the given pool. 05H ... Given map number is invalid. 06H ... Record not found. 07H ... Not enough memory for the free list available. 08H ... Not a possible user of the given pool. 09H ... Internal error within the battery backed-up RAM handler. 0AH ... Linked list not found. 0DH ... Memory error within the given map. 0EH ... Given map is not a data map. 0FH ... Given address is invalid. 10H ... Given record is already linked. 11H ... Given record is not linked. 14H ... There is no user data. 15H ... A pool withi the given pool ID already exists. 16H ... Not being applied for a common pool. 17H ... Not an owner of the given pool. 18H ... Given pool has been resized less than expected. FFH ... Pointer to record = FFh D2 - Location (routine), where the error ooccurred. 0BH ... OS.BATPOOLCRE 0CH ... OS.BATPOOLRES 0DH ... OS.BATPOOLREM 0EH ... OS.BATPOOLADD 0FH ... OS.BATALLOC 10H ... OS.BATALLINI 11H ... OS.BATALLDNSM 12H ... OS.BATALLINIDNSM 13H ... OS.BATFREE 14H ... OS.BATLFST 15H ... OS.BATLLST 16H ... OS.BATINS 17H ... OS.BATINSBEF 18H ... OS.BATUFST 19H ... OS.BATUFSTFRE 1AH ... OS.BATUFSTFRERES 1BH ... OS.BATULST 1CH ... OS.BATULSTFRE 1DH ... OS.BATULNK 1EH ... OS.BATULNKFRE 1FH ... OS.BATULNKFRERES 20H ... OS.BATFLST 21H ... OS.BATFLSTDNSM 22H ... OS.BATFNXT 23H ... OS.BATFNXTDNSM 24H ... OS.BATFPRV 25H ... OS.BATFPRVDNSM 26H ... OS.BATFNUM 27H ... OS.BATFNUMDNSM 28H ... OS.BATFIND 29H ... OS.BATFINDDNSM 2AH ... OS.BATSEARCH 2BH ... OS.BATSEARCHDNSM 2CH ... OS.BATQLINKED D3 - Undefined D4 - Undefined #CODE:AC,2 CODE=ACH BATTERY BACKED UP RAM USAGE ERROR. Default definition : ALARM Used by block : OS Category : DESIGNER This warning code indicates an usage error in the battery backed up RAM. D1 - Type of error 01H ... Generated by ARRAY.CREATE, if there isn't enough memory to create a new array. 02H ... Generated by ARRAY.CREATE, if the requested array already exists, but is of another size. 03H ... Generated by ARRAY.CREATE, if an existing, 'incorrect array' has been recreated. 04H ... Generated by ARRAY.CHECK, if a non recognized memory gap was found between two arrays. D2 - 0 D3 - Array identity or number of bytes in memory gab, high byte D4 - Array identity or number of bytes in memory gab, low byte #CODE:AD,2 CODE=ADH BATTERY BACKED UP RAM CHECK FAILED. Default definition : ALARM Used by block : OS Category : DESIGNER This warning is generated by ARRAY.CHECK, if an incorrect array was found. D1 - Statusbyte D2 - Number of records with checksum errors FFH ... Indicates 255 or more checksum errors found D3 - Array identity, high byte D4 - Array identity, low byte #CODE:AE,9 CODE=AEH FREE CIL BUFFER CHECK FAILED. Default definition : ERROR Used by block : OS Category : MAINTENANCE This code is only used, when the periodic resource check, initiated by the supervision programs, failed. The warning indicates that the maximum number of free buffers, located in the data map of the CIL application, that has been available since the last check, is smaller than the anticipated number. The cause can be, that the external CIL hardware is turned off or unable to receive the CIL information because of any other reason. D1 - D2 - CIL data map number D3 - Undefined D4 - Undefined Recommended action: Verify the connection of the external (peripheral) equipment and the programming of the relevant IO-channel. #CODE:AF CODE=AFH INVALID PASSWORD USED. Default definition : ALARM Used by block : PR Category : DESIGNER Several consecutive attempts, to log on with an invalid password, have been made. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:B0 CODE=B0H E2PROM FATAL ERROR (STOP 1). Default definition : STOP+NOPROG Used by block : E2 Category : MAINTENANCE This code will always cause a system restart that cannot be reprogrammed. The yellow led on the CPU front will indicate the stop reason with a single-flash led cadence. The warning code is used by the E2-handler, when an error concerning the first EEPROM-chip is detected during the initiation phase. This chip contains, among other data, a configuration variable, indicating, which EEPROM-chips that are mounted on the CPU board. This variable must be accessible during the initiation of the E2-handler. D1 - D2 - Type of error 01H ... The first EEPROM chip (position 190) is not mounted or contains illegal data. 02H ... An error has been detected, when a new value of the configuration variable should be updated at the end of the E2-handler initiation. D3 - Undefined D4 - Undefined #CODE:B6,8 CODE=B6H FIRST MG START UP PHASE NOT READY. Default definition : ERROR Used by block : MG Category : MAINTENANCE MG has not finished the first start up phase due to the current amount of messages and remains in this condition, until the messages are copied from E2 memory to RAM. During this time, MG is not active. D1 - D2 - Current state D3 - Undefined D4 - Undefined #CODE:B7,8 CODE=B7H MG START UP READY. Default definition : ERROR Used by block : MG Category : MAINTENANCE MG has finished the start-up and is now ready for traffic. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:B9 CODE=B9H E2DATA IS CONVERTED. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : CE Category : MAINTENANCE This warning is sent, when E2-data has been converted from the format of one release to another. D1 - D2 - Programming model D3 - Undefined D4 - Undefined #CODE:BA,0 CODE=BAH E2DATA CONVERSION ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : CE Category : MAINTENANCE A warning message with this code is generated, if the conversion of programmed data (see also warning code B9H) has been failed due to a read or write error in the semipermanent memory (EEPROM). D1 - State and individual number b7 - b4 ... Individual number b3 - b0 ... Current state D2 - Card position D3 - Undefined D4 - Undefined Recommended action: It is necessary to cold start the system. Afterwards the programmable data for the exchange needs to be programmed manually. #CODE:BA,1 CODE=BAH E2DATA CONVERSION ERROR. Default definition : ALARM+EXTERN+ACTIVE Used by block : CE Category : MAINTENANCE The warning is used, when either E2NAK or TIMEOUT1 is received as response to an E2-message during a common restart. D1 - Card position D2 - Individual number D3 - State D4 - 0 #CODE:BB CODE=BBH E2DATA CONVERSION OVERFLOW. Default definition : ALARM+EXTERN+ACTIVE Used by block : CE Category : MAINTENANCE The warning is used, when there was insufficient E2-memory to convert namestrings in the telephone directory. D1 - D2 - D3 - Undefined D4 - Undefined #CODE:BF CODE=BFH WAKEUP ERROR. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : HO Category : DESIGNER The warning is sent, if, after a wakeup call has been rerouted to the front desk, the front desk cannot be contacted due to some error condition. D1 - Directory number of extension, where wakeup failed, high byte D2 - Directory number of extension, where wakeup failed, low byte D3 - Undefined D4 - Undefined #CODE:C0,1 CODE=C0H SWITCH TX-LEVEL ERROR. Default definition : ERROR+TRIG Used by block : SX Category : DESIGNER The SX-block has detected some error, related to its handling of transmission levels. The SX-block has detected some error, related to its handling of transmission levels. D1 - Type of error 00H ... RP ordered to listen to a reserved PCM channel, order not executed. 01H ... RP ordered to send on a reserved PCM channel, order not executed. 02H ... RP ordered to send on a channel, where already one sender active, order is executed. 03H ... SX is ordered to adjust the transmission for a RP, connected to the silent channel, order not executed. D2 - PCM-channel Bit 0 - 5 ... Timeslot Bit 6 ... PCM-bus Bit 7 ... Not used D3 - Type of received message 00H ... Not specified 01H ... TRANSM,TRMREP 02H ... TRANSM,TRMCONSPK 03H ... TRANSM,TRMCONREQ 04H ... TRANSM,TRMCONNOM 05H ... TRANSM,TRMCONADJ 06H ... SXCNFCHANGE, SXCNFADD (SX-internal message) 07h ... SXCNFCHANGE, SXCNFREMOVE (SX-internal message) 08H ... SXCNFREL (SX-internal message) D4 - Sender of message (ST) #CODE:C1,1 CODE=C1H SWITCH CHANNEL RELEASE ERROR. Default definition : ERROR+TRIG Used by block : SX Category : DESIGNER The SX-block has detected, that an RP is still connected to a PCM channel although this channel has been released and delivered to a new party by OU.CHANNEL calls. D1 - Type of error Bit 0 ... Listening connection 0 ... No error 1 ... When a PCM-channel is requested, there is still one RP listening to this channel. Bit 1 ... Sending connection 0 ... No error 1 ... When a PCM-channel is requested, there is still one RP sending on this channel. Bit 2 ... Speech connection 0 ... No error 1 ... When a PCM-channel is requested, the previously connected RP is still in 'speech connection' (forgotten TRANSM, TRMCONNOM or TRANSM,TRMCONSPK). Bit 3 ... Not used Bit 4 ... Not used Bit 5 ... Not used Bit 6 ... PCM-bus Bit 7 ... Not used D2 - Card position, which is incompletely disconnected from the PCM-channel. D3 - Card position, which should be connected to the PCM-channel. D4 - Individual number, which should be connected to the PCM-channel. #CODE:C4,1 CODE=C4H DIGITAL LINK REPORT. Default definition : ERROR+TRIG Used by block : LS Category : MAINTENANCE LS-block has got report about some errors on a digital link. Actions, when -----------OCCURS------------- --CEASES-- errors occur Change Block Disconnect Deblock sync. new call ongoing call new call LOS,AIS,LFA,EBR x x x x RAI - x x x LMF,LMFR,SLIP2 - x - x SLIP1 x - - - D1 - Card position D2 - Link-report error codes 10H ... LOS, loss of signal. 11H ... AIS, alarm indication signal. 12H ... LFA, loss of frame synchronization. 13H ... EBR, excessive bit-error rate. 14H ... RAI, remote alarm indication. 15H ... LMF, loss of multi frame synchronization (not ISDN). 16H ... LMFR, loss of multi frame synchronization, remote side. 17H ... SLIP1, synchronization error, when master. 18H ... SLIP2, synchronization error, when not master. D3 - Fault counter for current alarm (total counter) D4 - Card position for current synchronization master, if any. #CODE:C4,7 CODE=C4 DIGITAL LINK REPORT. Default definition : ERROR+TRIG Used by block : LS Category : MAINTENANCE LS-block has got report about some error on a digital link. Actions, when -----------OCCURS------------- --CEASES-- errors occur Change Block Disconnect Deblock sync. new call ongoing call new call LOS,AIS,LFA,EBR x x x x RAI - x x x LMF,LMFR,SLIP2 - x - x SLIP1 x - - - D1 - Card position D2 - Link-report error codes 10H ... LOS, loss of signal. 11H ... AIS, alarm indication signal. 12H ... LFA, loss of frame synchronization. 13H ... EBR, excessive bit-error rate. 14H ... RAI, remote alarm indication. 15H ... LMF, loss of multi frame synchronization (not ISDN). 16H ... LMFR, loss of multi frame synchronization, remote side. 17H ... CCEI, continuously CRC error information. 18H ... SLIP1, synchronization error, when master. 19H ... SLIP2, synchronization error, when not master. D3 - Fault counter for current alarm (total counter) D4 - Card position for current synchronization master, if any. #CODE:C7,5 CODE=C7H CM COUNTER OVERFLOW. Default definition : ERROR Used by block : CM Category : MAINTENANCE The call meter function accumulates the total cost and number of received tax pulses for both, the originator and the trunk of all outgoing external calls. The directory numbers of the originator and the trunk are used as identifiers of the accumulators. The pulse counter can accumulate up to 16 777 215 pulses, before overflow. The cost is stored in exponential form and will, in practice, never overflow. This warning indicates, that the pulse counter has overflowed. After an overflow, both the pulse counter and the cost accumulator will be cleared. D1 - Directory number of the accumulator, which has overflowed, high byte D2 - Directory number of the accumulator, which has overflowed, low byte D3 - Undefined D4 - Undefined Recommended action: The call meter has not been read/reset in time. 16 777 215 pulses have been received and the cost can be calculated by multiplying this number with the price for one tax pulse. If the user of the current system is not interested in the call meter function, this warning has no meaning and should preferably be reclassified to NOLOG, else the error log will sooner or later be filled with this warning. #CODE:C8,5 CODE=C8H CM METER LIMIT EXCEEDED. Default definition : ALARM+INFO Used by block : CM Category : MAINTENANCE The call meter function accumulates the total cost and number of received tax pulses for both, the originator and the trunk of all outgoing external calls. The directory numbers of the originator and the trunk are used as identifiers of the accumulators. This warning indicates, that the limit, specified with command 6713 (Cost Limit), has been exceeded for a certain cost accumulator. D1 - Directory number of the accumulator, high byte D2 - Directory number, of the accumulator, low byte D3 - Undefined D4 - Undefined Recommended action: Read and reset the call meter for the appointed directory number. #CODE:C9,9 CODE=C9H INVALID TEI VALUE. Default definition : ERROR Used by block : TR Category : MAINTENANCE A call setup attempt was denied, because of an invalid terminal TEI value. D1 - Card position D2 - Individual number D3 - Faulty TEI value D4 - Undefined Recommended action: Check the TEI value at the ISDN terminal and / or command 1957 'Assigned TEI Values'. Valid TEI values are programmed (0 - 63) or automatically assigned (64 - 126). #CODE:CA,9 CODE=CA NO COMMON S-INTERFACE ACCESS NUMBER. Default definition : ERROR Used by block : TR Category : MAINTENANCE A call setup attempt was denied, because of no common number is programmed for the interface. D1 - Card position D2 - Individual number D3 - Undefined D4 - Undefined Recommended action: Check the programming of the common access number for the ISDN S-interface. Check command 1956 'Common Access Number'. #CODE:CB,9 CODE=CBH WRONG BASIC ACCESS MODE. Default definition : ERROR Used by block : TR Category : MAINTENANCE The programming of an ISDN S- / T-interface was not accepted, because the selected connection mode does not correspond to the reported hardware interface. D1 - Card position D2 - Individual number D3 - Undefined D4 - Undefined Recommended action: Check the programmed ISDN interface mode (command 1929) and / or the selection of the ISDN interface on the BTU-B DIP-switch. #CODE:CC,11 CODE=CCH CN ALTERNATIVE ROUTE USED. Default definition : UNDEFINED Used by block : TR Category : MAINTENANCE An outgoing CN call was cleared by the network because of a special network related reason and a new call setup attempt over the next PNR route choice is done. D1 - Card position D2 - Individual number D3 - Directory number of PNR, high byte D4 - Directory number of PNR, low byte #CODE:D0,9 CODE=D0H RP ICCU ERROR. Default definition : ERROR Used by block : ICCU Category : MAINTENANCE This code represents an unique warning code for the ICCU (Integrated Cordless Board). The warning is only intended as a help for the ICCU program designers. The validity of the user-defined parameters depends on the error code. D1 - User-defined error code D2 - User-defined data D3 - User-defined data D4 - User-defined data #CODE:D3,8 CODE=D3H WARNING W.SXTRM CAUSED. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The warning W.SXTRM has been caused. D1 - Process or device state D2 - Previous process state D3 - Card position D4 - Individual number #CODE:D4,8 CODE=D4H WARNING W.SXPCMRELRP CAUSED. Default definition : ERROR+TRIG Used by block : ALL Category : DESIGNER The warning W.SXPCMRELRP has been caused. D1 - Process or device state D2 - Previous process state D3 - Card position D4 - Individual number for BTU #CODE:D7,9 CODE=D7H CIL MEMORY CAPACITY EXCEEDED. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : CL Category : MAINTENANCE 500 CIL/HOTEL records are stored. The maximum storage capacity has been exceeded. D1 - D2 - D3 - Undefined D4 - Undefined Recommended action: Verify the programming of the external (peripheral) equipment and the programming of the IO-channels. #CODE:D8,9 CODE=D8H CIL MORE THEN 450 RECORDS STORED. Default definition : ALARM+INFO+EXTERN+ACTIVE Used by block : CL Category : MAINTENANCE More then 450 CIL/HOTEL records are stored in the E2-memory. The maximum capacity for CIL/HOTEL records on CPU-D3 is 500 records. D1 - D2 - D3 - Undefined D4 - Undefined Recommended action: Verify the connection of the external (peripheral) equipment. #CODE:DB,10 CODE=DBH FEATURE PROTECTED BY FECU. Default definition : ALARM+EXTERN+ACTIVE Used by block : ALL Category : MAINTENANCE An attempt to invoke a certain feature within the central software of ASB 150 02, or an attmpt to connect a specific hardware option to the exchange, was denied by the actual security level of the system. The programming of the current FECU (Feature Enabling Control Unit), connected to the front of the CPU-D4 central processor board, prohibits the execution of the feature or the activation of the hardware component. D1 - ST, which rejects the execution of the feature D2 - ID of the protected feature 00H ... Version 2.1 functionality of CTI. 01H ... Monitoring of operator instrument and queue. 02H ... Enhanced CIL functionality. 03H ... Tandem configuration with CTI. 04H ... Networking with QSIG. 05H ... Full networking (QSIG, VPN, UUS with MD 110). 06H ... Large / small scale networking. 07H ... ISDN caller list. 08H ... Enhanced individual abbreviated number. 09H ... Enhanced information system. 0AH ... GAP protocol. 0BH ... ACD - multiple call codes 0CH ... Swapping boards during operation 0DH ... Remote upgrading of central software 0EH ... Cordless remote O&M D3 - Undefined D4 - Undefined Recommended action: If the warning occurs because of a new hardware component, added to the exchange, or if the customer has purchased the related functionality, connect the appropriate FECU to the CPU-D4 board. #CODE:DB,12 CODE=DBH FEATURE PROTECTED BY FECU. Default definition : ALARM+EXTERN+ACTIVE Used by block : ALL Category : MAINTENANCE An attempt to invoke a certain feature within the central software of ASB 150 02, or an attmpt to connect a specific hardware option to the exchange, was denied by the actual security level of the system. The programming of the current FECU (Feature Enabling Control Unit), connected to the front of the CPU-D4 central processor board, prohibits the execution of the feature or the activation of the hardware component. D1 - ST, which rejects the execution of the feature D2 - ID of the protected feature 00H ... Version 2.1 functionality of CTI. 01H ... Monitoring of operator instrument and queue. 02H ... Enhanced CIL functionality. 03H ... Tandem configuration with CTI. 04H ... Networking with QSIG. 05H ... Full networking (QSIG, VPN, UUS with MD 110). 06H ... Large / small scale networking. 07H ... ISDN caller list. 08H ... Enhanced individual abbreviated number. 09H ... Enhanced information system. 0AH ... GAP protocol. 0BH ... ACD - multiple call codes 0CH ... Swapping boards during operation 0DH ... Remote upgrading of central software 0EH ... Cordless remote O&M 0FH ... not used 10H ... UUI Italy 11H ... Adaptions for CN numbering plan feature 12H ... Alternative routing on no line available 13H ... Override number restriction in ISDN (Austria) 14H ... ISDN Point to Multipoint 15H ... Multiple incoming call presentation 16H ... ECE ISDN number translation 17H ... Austrian Call metering tariffs 18H ... VMU-HD individual greeting 19H ... Integrated MOH 1AH ... Fictive number extended / improved 1BH ... CN/operator services active 1CH ... CTI groups 8/16 1DH ... Very small networking (4 interfaces) 1EH ... X.25 protocol and X.31 services (packet mode terminals) 1FH ... UUI in MSI of GFP D3 - Undefined D4 - Undefined Recommended action: If the warning occurs because of a new hardware component, added to the exchange, or if the customer has purchased the related functionality, connect the appropriate FECU to the CPU-D4 board. #CODE:DB,13 CODE=DBH FEATURE PROTECTED BY FECU. Default definition : ALARM+EXTERN+ACTIVE Used by block : ALL Category : MAINTENANCE An attempt to invoke a certain feature within the central software of ASB 150 02, or an attmpt to connect a specific hardware option to the exchange, was denied by the actual security level of the system. The programming of the current FECU (Feature Enabling Control Unit), connected to the front of the CPU-D4 central processor board, prohibits the execution of the feature or the activation of the hardware component. D1 - ST, which rejects the execution of the feature D2 - ID of the protected feature 00H ... Version 2.1 functionality of CTI. 01H ... Monitoring of operator instrument and queue. 02H ... Enhanced CIL functionality. 03H ... Tandem configuration with CTI. 04H ... Networking with QSIG. 05H ... Full networking (QSIG, VPN, UUS with MD 110). 06H ... Large / small scale networking. 07H ... ISDN caller list. 08H ... Enhanced individual abbreviated number. 09H ... Enhanced information system. 0AH ... GAP protocol. 0BH ... ACD - multiple call codes 0CH ... Swapping boards during operation 0DH ... Remote upgrading of central software 0EH ... Cordless remote O&M 0FH ... not used 10H ... UUI Italy 11H ... Adaptions for CN numbering plan feature 12H ... Alternative routing on no line available 13H ... Override number restriction in ISDN (Austria) 14H ... ISDN Point to Multipoint 15H ... Multiple incoming call presentation 16H ... ECE ISDN number translation 17H ... Austrian Call metering tariffs 18H ... VMU-HD individual greeting 19H ... Integrated MOH 1AH ... Fictive number extended / improved 1BH ... CN/operator services active 1CH ... CTI groups 8/16 1DH ... Very small networking (4 interfaces) 1EH ... X.25 protocol and X.31 services (packet mode terminals) 1FH ... UUI in MSI of GFP 20H ... Conversation recording 21H ... Diversion individual to external destination 22H ... Integrated Cordless - GAP 2.0 protocol 23H ... Multiple music on hold 24H ... O&M - Remote FW upgrading 25H ... Very small Networking (2 interfaces) 26H ... not used 27H ... not used 28H ... not used 29H ... not used 2AH ... not used 2BH ... not used 2CH ... not used 2DH ... not used 2EH ... not used 2FH ... not used 30H ... Automatic summer / winter time change from ISDN 31H ... Verified Account Codes 32H ... 3-Party conference on ISDN 33H ... Call forwarding with partial re-routing 34H ... Centrex Hook Flash over ISDN 35H ... Outcall notification 36H ... Number translation 37H ... Leave ACD queue via exit position 38H ... Multi number redial 39H ... IP Extensions proprietary, IP Extensions H.323 D3 - Undefined D4 - Undefined Recommended action: If the warning occurs because of a new hardware component, added to the exchange, or if the customer has purchased the related functionality, connect the appropriate FECU to the CPU-D4 board. #CODE:DB,14 CODE=DBH FEATURE PROTECTED BY FECU. Default definition : ALARM+EXTERN+ACTIVE Used by block : ALL Category : MAINTENANCE An attempt to invoke a certain feature within the central software of ASB 150 02, or an attmpt to connect a specific hardware option to the exchange, was denied by the actual security level of the system. The programming of the current FECU (Feature Enabling Control Unit), connected to the front of the CPU-D4 central processor board, prohibits the execution of the feature or the activation of the hardware component. D1 - ST, which rejects the execution of the feature D2 - ID of the protected feature 00H ... Version 2.1 functionality of CTI. 01H ... Monitoring of operator instrument and queue. 02H ... Enhanced CIL functionality. 03H ... Tandem configuration with CTI. 04H ... Networking with QSIG. 05H ... Full networking (QSIG, VPN, UUS with MD 110). 06H ... Large / small scale networking. 07H ... ISDN caller list. 08H ... Enhanced individual abbreviated number. 09H ... Enhanced information system. 0AH ... GAP protocol. 0BH ... ACD - multiple call codes 0CH ... Swapping boards during operation 0DH ... Remote upgrading of central software 0EH ... Cordless remote O&M 0FH ... not used 10H ... UUI Italy 11H ... Adaptions for CN numbering plan feature 12H ... Alternative routing on no line available 13H ... Override number restriction in ISDN (Austria) 14H ... ISDN Point to Multipoint 15H ... Multiple incoming call presentation 16H ... ECE ISDN number translation 17H ... Austrian Call metering tariffs 18H ... VMU-HD individual greeting 19H ... Integrated MOH 1AH ... Fictive number extended / improved 1BH ... CN/operator services active 1CH ... CTI groups 8/16 1DH ... Very small networking (4 interfaces) 1EH ... X.25 protocol and X.31 services (packet mode terminals) 1FH ... UUI in MSI of GFP 20H ... Conversation recording 21H ... Diversion individual to external destination 22H ... Integrated Cordless - GAP 2.0 protocol 23H ... Multiple music on hold 24H ... O&M - Remote FW upgrading 25H ... Very small Networking (2 interfaces) 26H ... Automatic summer / winter time change from ISDN 27H ... Verified Account Codes 28H ... 3-Party conference on ISDN 29H ... Call forwarding with partial re-routing 2AH ... Centrex Hook Flash over ISDN 2BH ... Individual Internal Diversion 2CH ... Outcall notification 2DH ... Enhanced Integrated Music on Hold 2EH ... Number translation 2FH ... Leave ACD queue via exit position 80H ... No final Licence file in Compact Flash of IPU before temporary licence expires D3 - Undefined D4 - Undefined Recommended action: If the warning occurs because of a new hardware component, added to the exchange, or if the customer has purchased the related functionality, connect the appropriate FECU to the CPU-D4 board. #CODE:DC,10 CODE=DCH PROTECTION LEVEL CHANGED. Default definition : ALARM+EXTERN+ACTIVE Used by block : CPU Category : MAINTENANCE A change in the protetion level of the system has been detected by the firmware on the CPU-D4 central processor board. The change could be either due to a removal of the FECU (Feature Enabling Control Unit) or due to a re-connection of the FECU and should not occur during normal operation. The protection level of the system is verified by the firmware on the CPU-D4 board every time, a supervision request is received from the central software. D1 - Previous protection level D2 - New (current) protection level D3 - Type of dongle D4 - Undefined Recommended action: If the warning occurs during normal operation without manual interaction of a service technician, the FECU is probably damaged and has to be replaced. #CODE:DF,10 CODE=DFH HSSC BUS ERROR. Default definition : ERROR Used by block : RP Category : DESIGNER This warning is used by all peripheral boards, equipped with a HSSC interface bus, to indicate an error condition on the HSSC bus. The meaning of the additional data bytes D2, D3 and D4 depends on the HSSC bus error condition, indicated in D1. D1 - Type of HSSC bus error 01H ... Error flags in interrupt event register set. 02H ... Error flags in buffer descriptor set (frame lost). 03H ... Too long HSSC frame (frame truncated). 04H ... No answer to HSSC frame (message lost). 05H ... Unexpected ACK received. 06H ... Switch over error (serial communication to HSSC). 07H ... Internal program error (HSSC driver). D2 - Additional HSSC bus error condition D3 - Source of errorneous message, if any D4 - Destination of errorneous message, if any #CODE:E2,11 CODE=E2H ALARM CAPACITY ERROR. Default definition : INFO Used by block : AL Category : MAINTENANCE This code is used, when a generated alarm was lost because the maximum storage capacity for alarms has been exceeded. D1 - Directory number of the extension, where the alarm failed, high byte D2 - Directory number of the extension, where the alarm failed, low byte D3 - Alarm time, high byte D4 - Alarm time, low byte #CODE:E3,13 CODE=E3H RP IPU WARNING. Default definition : UNDEFINED Used by block : IPU Category : DESIGNER Lowest IPU warning level. An abnormal condition in the program flow has been detected by the IPU software. The condition was safely handled by the software and does not require immediate user assistance. D1 - Originating IPU software block, high byte D2 - Originating IPU software block, low byte D3 - Details on the fault reason, high byte D4 - Details on the fault reason, low byte #CODE:E4,13 CODE=E4H RP IPU ALARM. Default definition : ALARM+EXTERN+ACTIVE+TRIG Used by block : IPU Category : DESIGNER Intermediate IPU warning level. A severe fault has been detected by the IPU software. Immediate attention and user assistance is required. D1 - Originating IPU software block, high byte D2 - Originating IPU software block, low byte D3 - Details on the fault reason, high byte D4 - Details on the fault reason, low byte #CODE:E5,13 CODE=E5H RP IPU ERROR. Default definition : ERROR Used by block : IPU Category : DESIGNER Highest IPU warning level. An extremely severe fault has been detected by the IPU software. There is no way of continuing the normal flow of control, so an immediate restart of the IPU board is required. D1 - Originating IPU software block, high byte D2 - Originating IPU software block, low byte D3 - Details on the fault reason, high byte D4 - Details on the fault reason, low byte #CODE:E6,14 CODE=E6H RP IPU FIRMWARE ERROR. Default definition : ERROR Used by block : IPU Category : DESGNER This code represents a warning associated to the FW on the IPU board. The warning is intended as help for the IPU FW designer. D1 - User-defined data D2 - User-defined data D3 - User-defined data D4 - User-defined data #CODE:E8,12 CODE=E8H FUNCTION ABORTED. Default definition : ERROR Used by block : MU Category : MAINTENANCE A specific feature within ASB 150 02 was aborted. The associated functionality can be evaluated using the signal input, which caused the warning. The definition of the warning code depends on the warning situation. This warning code is open to be used by other software blocks as applicable. D1 - D2 - Current state D3 - INFCODE of the last received message D4 - SUBCODE of the last received message #SUBCODE:50 RPCTRL 00h RPOFF ; OFF 01h RPSTARTUP ; STARTUP 02h RPBLOCKED ; BLOCKED 03h RPNORMAL ; NORMAL 04h RPUPGRADE ; UPGRADE 11h RPSTARTED ; Format and restart information to CP #SUBCODE:7E SURDY 00h SUWARM ; Warm start (normal restart) 01h SUCOLD ; Cold start (new e2base records) 02h SUBLKRDY ; Block ready (answer-message) 03h SUALLRDY ; All block ready for traffic. 04h SUBLKWAIT ; Block needs more time for initialization #SUBCODE:08 #SUBCODE:C7 CONCTRL CILCONSTAT 0 CON.REG ; Register 1 CON.RING ; Ringing 2 CON.SPEECH ; Speech 4 CON.TTTB ; Totally transparent, totally busy. 5 CON.TTNB ; Totally transparent, normal busy. 6 CON.PTNB ; Partial transparent, normal busy. 8 CON.OPTEST ; Test of operatorinstrument. 9 CON.VPAG ; Group voice paging 10 CON.WAIT ; Waiting, queued 11 CON.BREAKA ; Break-in 'A'-part 12 CON.BREAKB ; Break-in 'B'-part 13 CON.BREAKC ; Break-in 'C'-part 14 CON.CONF ; Conference 15 CON.DATARING ; Data call ring. 16 CON.DATACONN ; Data call connection. 17 CON.PTNBV ; Partial transparent, normal busy, volume 18 CON.REGREQ ; Register, request of keys one by one 19 CON.ALERT ; Ringing strted in network 20 CON.PROCEED ; End of selection in network 21 CON.SPEECHREG ; Speech and register state 22 CON.PROGRESS ; Progress indicator from ISDN line 23 CON.CONREC ; Converstation recording facility 24 CON.3PTYCONF ; External Call Hold and External Conference facility #SUBCODE:90 KEYCODE 00h KEY0 ; Keypad digit 0 01h KEY1 ; 1 02h KEY2 ; 2 03h KEY3 ; 3 04h KEY4 ; 4 05h KEY5 ; 5 06h KEY6 ; 6 07h KEY7 ; 7 08h KEY8 ; 8 09h KEY9 ; 9 0Ah KEYSTAR ; Keypad * 0Bh KEYSQR ; Keypad # 0Ch KEYSAVE ; SAVE 0Dh KEYMESS ; MESSAGE 0Eh KEYINFO ; INFO 0Fh KEYPF_0 ; Funktion key 0 0Fh KEYPICKUP ; PICKUP (alternative name of PF_0) 10h KEYONOFF ; ON/OFF 11h KEYMUTE ; MUTE alias KEYPF_4P (DBC 2XX familiy) 12h KEYCLEAR ; CLEAR 13h KEYR ; R 14h KEYPROG ; PROG 15h KEYDIAL ; Speed DIAL (erase,backspace in text mode) 16h KEYREAD ; READ & (space in text-mode) 17h KEYMENU ; MENU alias KEYPF_4Q (DBC 2XX familiy) 18h KEYHOLD ; HOLD 19h KEYTRANS ; TRANSFER 1Ah KEYDIV ; DIVERSION 1Bh KEYLINE1 ; LINE 1 1Ch KEYLINE2 ; LINE 2 1Dh KEYINQ ; INQUIRY 1Eh KEYPF_A ; Function key A 1Fh KEYPF_B ; B 20h KEYPF_C ; C 21h KEYPF_D ; D 22h KEYPF_E ; E 23h KEYPF_F ; F 24h KEYPF_G ; G 25h KEYPF_H ; H 26h KEYPF_I ; I 27h KEYPF_J ; J 28h KEYPF_K ; K 29h KEYPF_L ; L 2Ah KEYPF_M ; M 2Bh KEYPF_N ; N 2Ch KEYPF_O ; O, 1A on DSS1 2Dh KEYPF_O ; P, 1B on DSS1 2Eh KEYPF_O ; Q, 1C on DSS1 2Fh KEYPF_O ; R, 1D on DSS1 30h KEYPF_O ; S, 1E on DSS1 31h KEYPF_O ; T, 1F on DSS1 32h KEYPF_O ; U, 1G on DSS1 33h KEYPF_O ; V, 1H on DSS1 34h KEYPF_O ; W, 1I on DSS1 35h KEYPF_O ; X, 1J on DSS1 36h KEYPF_O ; Y, 1K on DSS1 37h KEYPF_O ; Z, 1L on DSS1 38h KEYPF_1 ; Soft key 1 39h KEYPF_2 ; 2 3Ah KEYPF_3 ; 3 3Bh KEYPF_4 ; 4 3Ch KEYENTER ; ENTER 3Dh KEYCONF ; CONFERENCE 3EH KEYMINUS ; Volume - 3FH KEYPLUS ; Volume + 40h KEYPF_1M ; Function Key 1M on DSS1 41h KEYPF_1N ; 1N on DSS1 42h KEYPF_1O ; 1O on DSS1 43h KEYPF_1P ; 1P on DSS1 44h KEYPF_1Q ; 1Q on DSS1 45h KEYPF_2A ; 2A on DSS2 46h KEYPF_2B ; 2B on DSS2 47h KEYPF_2C ; 2C on DSS2 48h KEYPF_2D ; 2D on DSS2 49h KEYPF_2E ; 2E on DSS2 4Ah KEYPF_2F ; 2F on DSS2 4Bh KEYPF_2G ; 2G on DSS2 4Ch KEYPF_2H ; 2H on DSS2 4Dh KEYPF_2I ; 2I on DSS2 4Eh KEYPF_2J ; 2J on DSS2 4Fh KEYPF_2K ; 2K on DSS2 50h KEYPF_2L ; 2L on DSS2 51h KEYPF_2M ; 2M on DSS2 52h KEYPF_2N ; 2N on DSS2 53h KEYPF_2O ; 2O on DSS2 54h KEYPF_2P ; 2P on DSS2 55h KEYPF_2Q ; 2Q on DSS2 56h KEYPF_3A ; 3A on DSS3 57h KEYPF_3B ; 3B on DSS3 58h KEYPF_3C ; 3C on DSS3 59h KEYPF_3D ; 3D on DSS3 5Ah KEYPF_3E ; 3E on DSS3 5Bh KEYPF_3F ; 3F on DSS3 5Ch KEYPF_3G ; 3G on DSS3 5Dh KEYPF_3H ; 3H on DSS3 5Eh KEYPF_3I ; 3I on DSS3 5Fh KEYPF_3J ; 3J on DSS3 60h KEYPF_3K ; 3K on DSS3 61h KEYPF_3L ; 3L on DSS3 62h KEYPF_3M ; 3M on DSS3 63h KEYPF_3N ; 3N on DSS3 64h KEYPF_3O ; 3O on DSS3 65h KEYPF_3P ; 3P on DSS3 66h KEYPF_3Q ; 3Q on DSS3 67h KEYPF_4A ; 4A on DSS4 68h KEYPF_4B ; 4B on DSS4 69h KEYPF_4C ; 4C on DSS4 6Ah KEYPF_4D ; 4D on DSS4 6Bh KEYPF_4E ; 4E on DSS4 6Ch KEYPF_4F ; 4F on DSS4 6Dh KEYPF_4G ; 4G on DSS4 6Eh KEYPF_4H ; 4H on DSS4 6FH KEY2ND ; 2'nd function key 70h KEYS.INV ; Invalid as key-code 71h KEYS.DIGIT ; Keypad (digits and *#) 72h KEYS.LINE ; Line-keys (3-line) 73h KEYS.PGM ; Programmable 74h KEYS.SOFT ; Soft function-keys 75h KEYPF_4I ; Function key 4I on DSS4 76h KEYPF_4J ; 4J on DSS4 77h KEYPF_4K ; 4K on DSS4 78h KEYPF_4L ; 4L on DSS4 79h KEYPF_4M ; 4M on DSS4 7Ah KEYPF_4N ; 4N on DSS4 7Bh KEYPF_4O ; 4O on DSS4 7Ch KEYD.CTI ; CTI 7Dh KEYD.ENDBLOCK ; Transfer on or more numbers in one msg 7Eh KEYS.WAITDT ; Wait for second dialtone 7Fh KEYS.INQSUP ; Inquiry in superior exchange 80h KEY_ALBUT ;RP Keycode for alarmbutton #SUBCODE:58 LCDCTRL 00h LCDTEXTSEL ; Select broadcast information #SUBCODE:6C #SUBCODE:65 TONECTRL MPCON 0 TONE.STOP ; Stop tone sending (Reconnect last PCM) 0 TONE.SILENCE ; Silence (request a 'quiet' toneprocess) 1 TONE.DIAL ; Dial tone 2 TONE.DIALSP ; Special dial tone 3 TONE.RINGSP ; Special Ring Tone (internally to LINE 2) 4 TONE.RING ; Ring Tone (freq. used for call waiting) 5 TONE.BUSY ; Busy Tone 6 TONE.CONG ; Congestion Tone 7 TONE.NU ; NU-tone 8 TONE.ACK ; Acknowledgement Tone 9 TONE.CALLVP ; Voice Paging Call Tone 10 TONE.DISC ; Disconnection Tone 11 TONE.CALLHA ; Handsfree Answering Call Tone 12 TONE.ERRMIN ; Minor Error Tone ( Used by PR-block ) 13 TONE.ERRMAJ ; Major Error Tone ( Used by PR-block ) 14 TONE.QUEUE ; Queue-tone 15 TONE.INACT ; Inactive tone 16 TONE.CONF ; Conference tone 17 TONE.BI ; Intrusion tone (Break in) 18 TONE.BIOP ; Intrusion tone (Break in from operator) 19 TONE.CONFOP ; Conference tone, operator 20 TONE.PARK ; Parking tone 21 TONE.ALTRING ; Alternative ring tone 22 TONE.ALTBUSY ; Alternative busy tone 23 TONE.ALTNU ; Alternative NU tone 24 TONE.ALTDIAL ; Alternative dial tone 25 TONE.OKAY ; Okay, continue (Short muted tone burst) 26 TONE.CWAIT ; Call waiting (tone burst) 27 TONE.CWAITR ; Call waiting (repetitive) 28 TONE.CONGRES ; Congestion Tone (no resources) 29 TONE.PUBDIAL ; Public dial tone 30 TONE.TEST ; Test tone 31 TONE.ERWT ; Expensive Route Warning Tone 0FEh MPTONE.NONE ; No need for any tone 0FFh MPTONE.PROCEED ; Proceed with earlier tone 0 TONELEV.INT ; Tonelevel for internal part. 1 TONELEV.EXT ; Tonelevel for external part. #SUBCODE:99 #SUBCODE:98 #SUBCODE:0D LEDRING LEDCTRL MULTPRES 0 LEDCAD.FREE ; Free indication, led off 1 LEDCAD.BUSY ; Busy indication, Continuous on 2 LEDCAD.CALL ; Call flash 3 LEDCAD.PARK ; Parking flash 4 LEDCAD.CONN ; Connected 0 LEDCAD.OFF ; Led off 1 LEDCAD.ON ; Continuous on #SUBCODE:70 #SUBCODE:7A #SUBCODE:7B SEIZACD ACDINFO ACDCTRL 1 ACDREADY ; Ready for a new ACD-call 2 ACDKEYS ; Info about keys that are defined for ACD 3 ACDNIGHT ; nightswitching 4 ACDTRPOS ; answering positions 5 ACDTRQ ; question of answeringpos 6 ACDTCD ; tcd-categories 7 ACDSILINTR ; Silent intrusion info 8 ACDGROUP ; Login / logout ACD group from CTI 9 ACDGROUPACK ; Acknowledge to ACD group from CTI A ACDGROUPNAK ; Not acknowledge to ACDGROUP message B ACDAGSTAT ; Set ACD agent status from CTI C ACDAGSTATACK ; Acknowledge to ACDAGSTAT message D ACDAGSTATNAK ; Not ackowledge to ACDAGSTAT message E ACDCCODE ; Send an ACD call code from CTI F ACDCCODEACK ; Acknowledge to ACDCCODE message 10 ACDCCODENAK ; Not acknowledge to ACDCCODE message 11 ACDGRPINFOQ ; Request ACD group parameter 12 ACDTIMOUTPAUS ; ACD pause time is elapsed 13 ACDCOMINFOUPD ; Common ACD parameter update 14 ACDRRERANSW ; Report answer of rerouted ACD call 15 ACDRRERDISC ; Report disconnect of rerouted ACD call 16 ACDRRERABAND ; Report abandon of rerouted ACD call 17 ACDRTFRANSW ; Report answer of transferred ACD call 18 ACDRTFRDISC ; Report disconnect of transferred ACD call 19 ACDRTFRABAND ; Report abandon of transferred ACD call 1A ACDRCALLTFRORIG ; Report ACD call transfer by originator 1B ACDRCALLTFRAG ; Report ACD call transfer by agent 1C ACDRTRSTATIDLE ; Report trunk goes idle 1D ACDRTRSTATBUSY ; Report trunk is being seized 1E ACDRONOACDCONN ; Report connect outgoing non ACD call 1F ACDRONOACDDISC ; Report disconnect outgoing non ACD call 20 ACDRINOACDANSW ; Report answer incoming non ACD call 21 ACDRINOACDDISC ; Report disconnect incoming non ACD call 22 ACDALLAGSTATQ ; Request status info of all agents 23 ACDALLAGSTAT ; Response to ACDALLAGSTATQ message 24 ACDOPDIR ; Directory numbers of operator 25 ACDCLERTIMQ ; Request ACD-group clerical times 26 ACDCOMINFOQ ; Request common ACD parameter 27 ACDNONBUSY ; ACD-agent busy with non-ACD-calls 28 ACDNONIDLE ; ACD-agent finished non-ACD-calls 29 ACDREROCTIAA ; ACD call was rerouted by AA for CTI 30 ACDSEIZREQ ; ACD-agent requests a seizcall message 1 ACDACTIVE ; Agent activated. 2 ACDPASSIVE ; Agent passivated. 3 ACDDELETED ; Agent deleted. 4 ACDPAUSE ; Agent paused. #SUBCODE:24 #SUBCODE:C9 REROUTE CILCONREL 0 RER.NOTS ; Not specified 1 RER.TFR ; Transfer. 2 RER.DNR ; Diversion on no reply. 3 RER.BRK ; Break in. 4 RER.CNF ; Conference 5 RER.OPR ; Operaror recall,after 'parked by operator' 6 RER.NIN ; Information not available, 7 RER.MG ; Reroute call to MG ...... 8 RER.TFRBFA ; Transfer before answer. 9 RER.CB ; Call back. 10 RER.ACD ; Reroute of ACD-call. 11 RER.SIL ; Reroute on silent intrusion. 12 RER.BRKKEEP ; Reroute, break in, keep display 13 RER.LCRRDY ; Least cost routing ready 14 RER.LCRREQ ; Least cost routing request 15 RER.COBEXT ; Reroute common bell extension 16 RER.CANSWPOS ; Exit storing and retrieving of messages 17 RER.NMSG ; Override multiple diversion to MG 18 RER.FACEXIT ; Exit from a facility to the desired dir.nr. 19 RER.CTI ; Reroute caused by CTI 20 RER.BYP ; Reroute bypassing call diversion 21 RER.DNA ; Diversion on cordless not available 22 RER.CNBYP ; Reroute bypassing call diversion at calls to a CN party 23 RER.CNDNR ; Reroute on no reply to a CN diverted-to party 24 RER.CNDIV ; Reroute on CN call diversion immediate, on busy or on ; no reply when diverting party is another PBX 25 RER.FACBUSY ; Reroute from facility to exit position ; because the desired party is busy 26 RER.CNDNA ; Diversion on cordless not available to a CN diverted-to ; party 27 RER.CONREC ; Reroute on conversation recording 28 RER.3PTYCONF ; Reroute request to EX/OP from TR...... #SUBCODE:EU #SUBCODE:IO #SUBCODE:CA EUSEIZ 10h EUSPRINT ; Local printing. 11h EUSDATA ; Data transparent, local. 14h EUSMESS ; Message transparent, local. #SUBCODE:CB EUCTRL 00h EUCSZACK ; Seizure (EUSEIZ) acknowledge. 01h EUCSZNAK ; Seizure (EUSEIZ) negative acknowledge. 02h EUCCALL ; Call from connected PC/terminal. 03h EUCONRDY ; Ready for transfer. 04h EUCONREL ; Release IO-connection. 05h EUCONEND ; IO-connection released. 06h EUCMCALLOW ; Allow multiplexed communication. 07h EUCWAITREQ ; Request to interrupt current output 08h EUCWAITACK ; Interrupt acknowledged 09h EUCWAITNAK ; Interrupt not acknowledged 0Ah EUCWAITRDY ; Current output is copleted, ready to wait 0Bh EUCRESUME ; Resume interrupted output 0Ch EUCBUSY ; ASB-block is busy, answer to EUCCALL 0Dh EUCRDYSWUPD ; Ready for remote software update #SUBCODE:CC IOINIT 01h V24IDLE ; Idle. 10h V24PRINT ; Local printing. 12h V24DATAA ; Data transparent, local, A-part. 13h V24DATAB ; Data transparent, local, B-part. 22h V23DATAA ; Data transparent, remote, A-part. 23h V23DATAB ; Data transparent, remote, B-part. #SUBCODE:CD IOCTRL 00h IOCINITACK ; Init acnowledge. 01h IOCINITNAK ; Init negative acnowledge. 02h IOCCALL ; Call from conneced PC/terminal. 03h IOCERR ; IO-error,(please, release me). 04h IOCCONREL ; Release CSM connection 08h IOCSNDREQ ; Request of data sending. 09h IOCSNDRDY ; RP ready to send data. (IODATA) 0Ah IOCSNDEND ; No more data to send, stand by. 0Bh IOCRECREQ ; Request of data receiving. 0Ch IOCRECRDY ; CP ready to receive data (IODATA) 0Dh IOCRECEND ; No more to receive, stand by. 0Eh IOCNEWPROT ; Change line protocol 0Fh IOCMDMRDY ; Modem is ready to send data 10h IOCSNDENDREQ ; No more data to send and request of correct sending to ; external unit 11h IOCSNDOUT ; RP sends current data package to external unit ; correctly 12h IOCSNDCLEAR ; All temporariliy stored data packages are deleted #SUBCODE: IODATA 00h IODSND ; Data to external unit. 01h IODREC ; Data from external unit. #SUBCODE:BF QUEUEINFO 00h QUEUEINFOQ ; Question of calls in a camp-on queue 01h QUEUEINFOANSW ; Answer #SUBCODE:BC OPINFO 00h OPMETER ; Set meteringcall info 01h OPMETERR ; Reset meteringcall info 02h OPSERIAL ; Set serialcall info 03h OPSERIALR ; Reset serialcall info #SUBCODE:4F #SUBCODE:C9 CONRELCTRL CILCONREL 00h CRCREGNEW ; Release, start with new regtone 01h CRCREGKEEP ; Release, start with new regtone, keep proc 02h CRCCBBOOK ; Release, book for specified party. 03h CRCACDRERO ; Release from ACD, reroute. 04h CRCLCRBUSY ; No free trunk after Least cost routing anal. 05h CRCCALLPROG ; Release with progress info from net 06h CRCPICKUP ; Pickup common bell extension not allowed 07h CRCPICKUPNR ; Pickup common bell extension not allowed 08h CRCDISA ; Setup of transitcall after succesful DISA login 09h CRCALTROUTE ; Alternativ routing because of a network specific ; reason 0Ah CRCROP ; 'Switch over' of an ongoing IP-call #SUBCODE:0F TEXTSTRING 00h TXTINFOQ ; Ask for text information 01h TXTINFOACK ; Answer with text. 02h TXTINFONAK ; Answer without text. 10h TXTACD ; Text fom ACD 20h TXTDINAME ; Name string information (from DI) 30h TXTGUESTQ ; Ask for guest checkin data 31h TXTGUESTACK ; Answer, with text for guest 32h TXTGUESTNAK ; Answer, without text for guest 40h TXTFSOPI ; Name string for free seating CTI OPI #SUBCODE:4D MICTRL 00h MIMGIND ; Message indication from MG-block 01h MIININD ; Information indication from IN-block 02h MIHOIND ; Wakeup indication, DNDindication, clear last ; saved number, individual status for RTR and DID 03h MIEXIND ; Voice mail indication from EX-block 04h MIININDQ ; Check Voice information from IN-block 05h MIINREL ; Release connection and stop play 06h MIININDANSW ; Information from IN 07h MIMGINDQ ; Check unanswered messages from MG-block 08h MIMGINDANSW ; Answer message to MIMGINDQ 09h MIINDIRECT ; direct diversion 0Ah MIINBUSY ; diversion on busy 0Bh MIINNOREPLY ; diversion on no reply 0Ch MIMGREC ; Conversation recording indication 0 MIMGNONE ; No message to extension 1 MIMGX ; Message exists 2 MIMGCHECK ; Message checked 0 MIINNONE ; No information for extension 1 MIINTEXT ; Text information active 2 MIINVOICE ; Voice information active 3 MIINPREDEF ; Predefined information active 4 MIINGRTON ; Ind. mailbox greeting exists 5 MIINGRTOFF ; Ind. maibox greeting does not exist 0 MIHONONE ; Wakeup not ordered for extension 1 MIHOWAKEUP ; Wakeup ordered for extension 2 MIHONODND ; Deactivate Do not disturb for extansion 3 MIHODND ; Activate do not disturb for extansion 4 MIHOLSCLR ; Delete last saved number 5 MIHOINDBARR ; Individual status for RTR and DID 0 MIEXNONE ; No external voice mail to extension 1 MIEXVMAIL ; External voice mail to extension exist 0 MIINNOPLAY ; No play, if absence information active 1 MIINPLAY ; Play voice or predefined info for ext. 2 MIINRECORD ; record personal greeting 3 MIINERASE ; erase personal greeting 4 MIINSTORE ; store personal greeting 5 MIINREWPLAY ; rewind play during config of pers.gr. 4 MIINCONN ; Connection with IN established 5 MIINACK ; pos. answer for PG request 6 MIINNAK ; neg. answer for PG request 7 MIINFAULT ; neg. answer for PG request 0 MIINRELNOANSWER ; No answer message to MG necessary 1 MIINRELANSWER ; Answer after VMU channel is released 0 MIMGRECOFF ; Conversation recording off 1 MIMGRECON ; Conversation recording on 2 MIMGRECFLASH ; Conversation recording last 10 seconds #SUBCODE:7F REALTIME 00h RTCMIN01 ; Every minute 01h RTCMIN05 ; Every 5:th minute 02h RTCMIN15 ; Every 15:th minute 03h RTCMIN30 ; Every 30:th minute 04h RTCMIN60 ; Every 60:th minute 04h RTCHOUR01 ; Every hour (same as 60 min) 05h RTCHOUR03 ; Every 3:rd hour 06h RTCHOUR06 ; Every 6:th hour 07h RTCHOUR12 ; Every 12:th hour 08h RTCHOUR24 ; Every 24:th hour 40h RTCWR ; Write time in time circuit 41h RTCWRANSW ; Answer after a write 50h RTCRD ; Request real time 51h RTCRDANSW ; Answer after a read 60h RTCMINUTE ; Periodical minute-message from RP #SUBCODE:8A #SUBCODE:B9 VMUSEIZ VMSEIZ 10h WRINFO ; Write (record) voice information 11h WRMESS ; Write voice message 12h WRANNO ; Write voice announcement 20h RDINFO ; Read (play) voice information 21h RDMESS ; Read voice message 22h RDANNO ; Read voice announcement 23h VMRESERVE ; Reserve a channel at VMU-card 24h VMRELEASE ; Release a reserved channel at VMU-card #SUBCODE:8B #SUBCODE:BA #SUBCODE:8F VMUSEIZANSW VMSEIZANSW VMUORDERANSW 0 VMACK ; Seizure accepted 1 VMACKREL ; Seizure accepted, no connection needed 2 VMNAKBUSY ; Seizure rejected, channel busy 3 VMNAKREF ; Seizure rejected, reference error 4 VMNAKCAP ; Seizure rejected, capacity shortage 5 VMNAKINS ; Seizure rejected, card not installed 6 VMNAKPROG ; Seizure rejected, no reference for the dir.no 7 VMNAKTO ; Seizure rejected, time out (no VMU-answer) 8 VMNAKBLK ; Seizure rejected, no card or no time allocated 9 VMNAKQ ; Reservation not possible #SUBCODE:B8 VMUORDER2 0 VMACK ; Seizure accepted 1 VMACKREL ; Seizure accepted, no connection needed 2 VMNAKBUSY ; Seizure rejected, channel busy 3 VMNAKREF ; Seizure rejected, reference error 4 VMNAKCAP ; Seizure rejected, capacity shortage 5 VMNAKINS ; Seizure rejected, card not installed 6 VMNAKPROG ; Seizure rejected, no reference for the dir.no 7 VMNAKTO ; Seizure rejected, time out (no VMU-answer) 8 VMNAKBLK ; Seizure rejected, no card or no time allocated 9 VMNAKQ ; Reservation not possible 30h ERINFO ; Erase one voice information 31h ERMESS ; Erase one voice message 32h ERANNO ; Erase one voice announcement 40h CLINFO ; Erase all voice informations 41h CLMESS ; Erase all voice messages 42h CLANNO ; Erase all voice announcements 50h CLALL ; Erase all #SUBCODE:8D VMUDATAANSW 0 VMREFACK ; Reference found 1 VMREFNAK ; Reference not found 2 VMREFERR ; Reference error 5 PREDEFACK ; deliveres references 6 PREDEFNAK ; no VMU-HD or storing not allowed #SUBCODE:B6 VMUCTRLDATA 0 VMREFACK ; Reference found 1 VMREFNAK ; Reference not found 2 VMREFERR ; Reference error 3 DATAQ ; Data information about VMU-HD 4 PREDEF ; Inquire prerecorded announcements 5 PREDEFACK ; deliveres references 6 PREDEFNAK ; No VMU-HD or storing not allowed 7 RESOURCE ; Resource information about VMU-HD #SUBCODE:8E VMUORDER 30h ERINFO ; Erase one voice information 31h ERMESS ; Erase one voice message 32h ERANNO ; Erase one voice announcement 40h CLINFO ; Erase all voice informations 41h CLMESS ; Erase all voice messages 42h CLANNO ; Erase all voice announcements 50h CLALL ; Erase all #SUBCODE:BB VMCTRL 10h VMPLAY ; Start play 11h VMREWPLAY ; Rewind and start play 12h VMSTOP ; Stop 13h VMEXIT ; Release connection without storing/erase 20h VMREC ; Start record 21h VMREWREC ; Rewind and start record 22h VMSTORE ; Store information and release connection 25h VMPLAYRESA ; Start playing of announcment 26h VMPLAYRESI ; Start playing of information 27h VMPLAYRESM ; Start playing of message 30h VMTIM ; Time information 31h VMPLAYRDY ; End of play 32h VMRECEND ; End of record 33h VMREL ; Answer on a VMEXIT or a VMSTORE 34h VMSTORERDY ; Answer on a VMSTORE 35h VMRELRES ; Answer signal to CP block form VM 36h VMRECSIL ; Silence detected #SUBCODE:AD METER 0 METSTART ; Init metering 1 METCHANGE ; Int metering for new extension/trunk 2 METREL ; Stops metering 3 METRDYCHG ; Metering for a call is ended and restarted 4 METRDYREL ; Metering for a call is ended and released 5 METCONQ ; Ask for pulses and duration 6 METANSW ; Answer 9 METSEIZ ; Seizure of a meter 10 METSEIZACK ; Answer, metering present and available 11 METSEIZNAKNA ; Answer, metering equipment not present 12 METSEIZNAKB ; Answer, metering equipment busy 14 METAOCNAK ; Reject of metering at ISDN 15 METREADCALL ; Answer message for current call 16 METRESETCALL ; Reset addressed accumulator of a caller 17 METACKCALL ; Answer contained accumulated pulses... 18 METNAKCALL ; Negative answer to read or reset..... 19 METCONANSW ; Answer message for current call 20 METLASTCALL ; Last adding to meter of caller 21 METSAVECALL ; Adding to meter of a caller 22 METLASTTRNK ; Last adding to meter of a trunk 23 METSAVETRNK ; Adding to meter of a trunk #SUBCODE:C6 CILCONDAT 0 CLINIT ; 1 CLINITTR ; 2 CLCDTEST ; 3 CLRECALL ; 4 CLTAG ; #SUBCODE:C8 CILDIGSEND 0 CLDIG ; Digits transmitted to external destination 1 CLACCINIT ; (Re)start reception of Account Code digits 2 CLACCDIG ; Account Code digits 3 CLLCRDIAL ; Dialled digits at LCR-analysed calls 4 CLLCRSENT ; Sent digits at LCR-analysed calls 5 CLPNRSENT ; Sent digits at private network router 6 CLACCREQ ; Request for Account Code digits 7 CLACCACK ; Sending of Accout Code 8 CLACCNAK ; No Accout Code 0 CLVLDSND ; Validity data 1 CLVLDCON ; #SUBCODE:C9 CILCONREL CLREGNEW CRCREGNEW+30h ; CLREGKEEP CRCREGKEEP+30h ; CLCBBOOK CRCCBBOOK+30h ; 60h CLSZBOOK ; 61h CLMETER ; 62h CLCONSENT ; 63h CLCONREC ; 90h CLBUFCONG ; 91h CLACCONG ; 92h CLACCERR ; #SUBCODE:C5 CILSERVICE 0 CNTFR ; at CN transfer 1 CFPR ; at Partial Rerouting (ISDN suppl. service) 2 THREEPTYCONF ; at 3 party conference (ISDN stimulus service) #SUBCODE:BE DIGREQ 0 DIGTFRQ ; Question of operators pre-dialled digits 1 DIGTFRANSW ; Answer on DIGTFRQ #SUBCODE:AE PCCTRL 0 PCCPWNAK ; Neg acknowledge 1 PCCPWACK ; Acknowledge 2 PCCPWRD ; Password read 3 PCCPWRDANSW ; Password read, answer 4 PCCPWWR ; Password write 5 PCCCONREL ; Connection release 6 PCCACCESS ; Accesslevel request 7 PCCACCESSANSW ; Accesslevel respond 8 PCCTRANSP ; Transparent communication with EC 9 PCCRECALL ; Recall proceed control (from EC) 10 PCCRECALLQ ; Recall question (from EC) 11 PCCRECALLANSW ; Recall answer (from CP) #SUBCODE:AC MISTOCLR 0 MIMGCLRTO ; Clear all messages to extension 1 MIMGSTORE ; Store 'call-me' message 2 MIINCLR ; Clear information for extension 3 MIMGERASE ; Erase message #SUBCODE:AB GUESTINFO 0 HOGUESTOFF ; Guest extension facillity deactivated 1 HOGUESTON ; Guest extension facillity activated 10h HOGUESTACK ; Operation successed 11h HOGUESTNAK ; Operation failed #SUBCODE:47 CPJOB 000h CPJUNDEF ; Job undefined 010h CPJPRODNUM ; Ask of part of CXC-number 011h CPJPRODNUMANSW ; Answer 020h CPJSETFORMAT ; Set communication format 030h CPJREAD ; Read CP-memory 031h CPJREADI ; Read CP-memory, indirect 032h CPJREADIND ; Read CP-memory, individual ram 03Fh CPJREADANSW ; Answer 040h CPJTESTSTART ; RP Setup message for test 041h CPJTESTLOG ; RP Setup message for starting log 042h CPJTESTEND ; RP Test disable 043h CPJTESTLOGMPD ; RP Setup message for starting log for MPD 050h CPJTESTBOARD ; RP Identification of testboard 0E0h CPJOMPCCOM ; Command to PC handler in OM-block. 0F0h CPJMESS ; A short message packed and sent in complete form with one CPJOB-message 0F1h CPJMESSFST ; First part of a long, packed, message. 0F2h CPJMESSMID ; Middle parts, of a packed message. 0F3h CPJMESSLST ; Last part of a packed message. #SUBCODE:9C ELPAR 00h ELPCOMA ; Common parameters 01h ELPTRANSMA ; Transmission parameters 02h ELPRINGCADA ; Ring cadences for ELUA 03h ELPRINGCADC ; Ring cadences for ELUC 04h ELPRINGCADD ; Ring cadences for ELUD 05h ELPRINGDEFD ; Ring character, volume 06h ELPTRANSMD ; Transmission parameters ELUD 07h ELPALRTIM ; Alerting timeout parameter ICCU2 80h ELPACK ; Parameter okay 81h ELPNAK ; Parameter not okay #SUBCODE:A9 E2STATUS 1 E2STATMAPQ ; E2 status question, single map 2 E2STATALLQ ; E2 status question, all maps 3 E2STATANSW ; E2 status answer 4 E2TEST ; E2 test request 5 E2TESTANSW ; E2 test answer 6 E2TESTERROR ; E2 test error #SUBCODE:AA PGINFO 00h PGINPROG ; Paging in progress 01h PGABSENCE ; Paged party not present #SUBCODE:A8 TRTRANSIT 00H TRSEOSF ; End of selection, free 01H TRSEOSB ; End of selection, busy 02H TRSENDS ; End signal 10h TRSSUBS ; Calling party is a subscriber 11h TRSOPER ; Calling party is an operator 12h TRSADIG ; A-number digit 13h TRSAEND ; End of A-number 14h TRSAREJ ; Request of A-number rejected 15h TRSEXTDIV ; External diverted call 20h TRSACAT ; Request of A-chategory 21h TRSADDCMP ; Complete address 22h TRSBAR ; Congestion or barred number 23h TRSBUSY ; Called party busy 24h TRSCONG ; Congestion before complete address 25h TRSFREE ; Called party free 26h TRSSETUP ; No result available, setup speech 27h TRSUNALLO ; Unallocated number 28h TRSNXTDIG ; Transfer of next digit 29h TRSREQANO ; A-number request 2Ah TRSREQCLL ; A-number request to incoming conn. TRUNK 2Bh TRSREQGRA ; A-group digits of B-number request to incoming ; conn. TRUNK 2Ch TRSREQGRC ; C-group digits of B-number request to incoming ; conn. TRUNK 2Dh TRSREQALL ; All digits of B-number request to incoming conn. ; TRUNK 2Eh TRSSUBREJ ; Request of A-category rejected 2Fh TRSLINEOUT ; Lineout before complete address 40h TRSIRELEASE ; ISDN trunk has been released 41h TRSIFREE ; IDSN trunk is released and free 42h TRSIPROGRESS ; Informs opposite ISDN party that ISDN trunk ; received SISIG,SIPROGRESS (with transparent data) 45h TRSIFDATA ; i->o 46h TRSIFDATAEND ; o->i ended 47h TRSIBDATA ; i->o 48h TRSIBDATAEND ; o->i ended 49h TRSISETUP ; Sends SISETUP data to opposite trunk 4Ah TRSICNSETUP ; Sends SICNSETUP data to opposite trunk 4Bh TRSIUUISETUP ; Sends SIUISETUP to opposite trunk 4Ch TRSISEIZACK ; Seizure acknowledge from FW on outgoing side 4Dh TRSICNALERT ; Sends SICNALERT data to opposite trunk 4Eh TRSIUUIALERT ; Sends SIUUIALERT data to opposite trunk 4Fh TRSIADDUUIALERT ; Sends SIUUIBANSWER data to opposite trunk 50h TRSISPEECH ; Sends SIBANSWER data to opposite trunk 51h TRSICNSPEECH ; Sends SICNBANSWER to opposite trunk 52h TRSIUUISPEECH ; Sends SIUUIBANSWER to opposite trunk 53h TRSICNDISC ; Sends SICNDISC data to opposite trunk 54h TRSIUUIDISC ; Sends SIUUIDISC data to opposite trunk 55h TRSIUUI ; Sends SIUUIIN data to opposite trunk 56h TRSIADDUUI ; Sends SIADDUUIIN data to opposite trunk 57h TRSIFACILITY ; Sends SIFACILITY data to opposite trunk 58h TRSIUUISERVICE ; Sends SIUUISERVICE data to opposite trunk 59h TRSIVIRSEIZACK ; Seizure acknowledge from FW on outgoing side 70h TRSIRGSDIGIT ; Sends data received in SIRGSDIGIT to opp. trunk B4h TRSLOCSPEECH ; MFC transit, call category : local speech B5h TRSLOCDATA ; MFC transit, call category : local data B6h TRSSEMIAUTO ; MFC transit, call category : semi automatic B7h TRSTOLLCALL ; MFC transit, call category : toll automatic B8h TRSTESTCALL ; MFC transit, call category : test #SUBCODE:86 #SUBCODE:87 HOCILINPUT HOCILOUTPUT 1 CLHOCHECKIN ; Checkin 2 CLHOCHECKOUT ; Checkout 3 CLHOUPDATE ; Update Guest 4 CLHOMESSORD ; Message Order 5 CLHOMESSCLR ; Message Clear 6 CLHOWAKEORD ; Wake-Up Order 7 CLHOWAKEANS ; Wake-Up Answer 8 CLHOWAKECLR ; Wake-Up Clear 9 CLHOBAR ; Phone Barring 10 CLHOUNBAR ; Phone Unbarring 11 CLHOROOMSTAT ; Room Status 12 CLHOPHONE ; Phone Status 13 CLHOGUEST ; Guest Data 14 CLHOBARSTAT ; RTR/DID Status 15 CLHOBARALL ; All guest extensions are barred to do ; outgoing calls because of an overflow ; concerning the CIL buffers 16 CLHOUNBARALL ; All guest extension barring status are ; restored because there are CIL bufers ; available again #SUBCODE:78 UPDCARD 1 SUCARDDEL ; E2-data for a removed card will be deleted. 2 SUCARDINS ; E2BASE areas for a new card are installed. 3 SUSHDWNREQ ; Request shutdown of card 4 SUSHDWNEXEC ; Execute card shutdown 5 SUSHDWNACK ; Acknowledge to SUSHDWNREQ and SUSHDWNEXEC 6 SUCARDDELACK ; Acknowledge to SUCARDDEL 7 SUSHDWNDELACK ; Acknowledge to SUSHDWNDEL 8 SUSHDWNINS ; Shutdown of VMU-HD unit 9 SUSHDWNAUT ; Automatic restart of VMU-HD unit #SUBCODE:43 ACBCTRL 0 ACBDEL ; Delete callback orders 1 ACBCNDEL ; Delete CN call back mission request 2 ACBCNDELANSW ; Answer to delete CN call back mission request 3 ACBCNACT ; CN call back free notification 4 ACBCNACTANSW ; Answer to CN call back free notification 5 ACBCNDELINFO ; CN call back mission was deleted #SUBCODE:0E NEWNO 0 NEW.ABBR ; New number, from abbreviated dialling 1 NEW.NAME ; New number, from directory book 2 NEW.LNR ; New number, from last dialled number 3 NEW.SNR ; New number, from last saved number 4 NEW.CTI ; New number, from telephony server 5 NEW.VPN ; New number, from virtual private networking 6 NEW.ABBI ; New number, from ind. abbr. dialling 7 NEW.CI ; New number, from ISDN caller list 8 NEW.IED ; New number, from ind. ext. diversion 9 NEW.ROP ; New number, for route optimizing #SUBCODE:16 E2RECORD 0EDh E2RECRDFST ; Read first record linked to basic E2-record 0EEh E2RECRDNXT ; Read next record linked to basic E2-record 0EFh E2BASPRMRD ; Read programming model number of E2-base 0F0h E2BASPRMWR ; Write programming model number of E2-base 0F1h E2RECPRMRD ; Read programming model number of E2-record 0F2h E2RECPRMWR ; Write programming model number of E2-record 01h CERECCREATE ; Indication for application blocks that CE ; has seized additional E2 record ; (contents only data converted by CE) #SUBCODE:45 ECCOM 00h ECBASRD ; E2base-connected messages, forward 01h ECBASWR ; 02h ECBASSZ ; 03h ECBASRL ; 04h ECBASSWAP ; 10h ECBASRDANSW ; E2base-connected messages, backward 11h ECBASWRANSW ; 12h ECBASSZANSW ; 13h ECBASRLANSW ; 14h ECBASSWAPANSW ; 20h ECRECRD ; E2record-connected messages, forward 21h ECRECRDFST ; 22h ECRECRDNXT ; 23h ECRECWR ; 24h ECRECSZ ; 25h ECRECRL ; 30h ECRECRDANSW ; E2record-connected messages, backward 31h ECRECRDFSTANSW ; 32h ECRECRDNXTANSW ; 33h ECRECWRANSW ; 34h ECRECSZANSW ; 35h ECRECRLANSW ; 40h ECPRRD ; PR-family-connected messages, forward 41h ECPRWR ; 50h ECPRRDANSW ; PR-family-connected messages, backwards 51h ECPRWRANSW ; #SUBCODE:9A NUMINFO 0 NUM.NEWORIG ; Display new original number #SUBCODE:22 CONINFO 00h CONI.REAACT ; Reanswer function activated 01h CONI.REAREL ; Release during activated reanswer 02h CONI.REANSW ; Reanswer during activated reanswer 03h CONI.KEYREQ ; Request of one key from the orginator 04h CONI.CALLPROG ; Call progress info, from external party 05h CONI.KEYRES ; Trunk must reset the keybuffer 06h CONI.CNDIV ; Diversion was executed in another CN PBX 07h CONI.CNDNR ; Diversion info was forwarded to term. PBX 08h CONI.CNSOR ; Signal to term. to initiate ringing 09h CONI.CNTFR ; New connected provate identity 0Ah CONI.ANUM ; Calling party number 0Bh CONI.FREL ; A-party requests forced release of C-party 0Ch CONI.ACDTFR ; CONINFO ACD transfer 0Dh CONI.BUSY ; Call queued because of busy destination 0Eh CONI.REGREQ ; Request DTMF register 0Fh CONI.REGACK ; Register posivite acknowledge F0h CONI.REGNAK ; Register negative acknowledge F1h CONI.REGREL ; Register release #SUBCODE:97 ELCTRL 00h ELCCWTONE ; Order call-waiting tone to instrument. 01h ELCKEYREL ; Control of INSTRTYPE messages 02h ELCLINEBR ; Order linebreak 03h ELCINDMODEC ; Instrument mode for ELUC 04h ELCINDMODED ; Instrument mode for ELUD 05h ELCFUNC ; Function control 06h ELCTONE ; Start/stop tonesending 07h ELCANAMODE ; Mode control (ELUA) 08h ELCLEVELD ; Loudspeaker and earpice level (ELUD) 09h ELCDIR ; Accociated directory number 0Ah ELCLCDPAR ; Special cordless display characters #SUBCODE:40 CARDREP 00h CREPORT ; Card report request 10h CREPORTANSW ; Card report answer 11h CTYPEANSW ; Card type answer #SUBCODE:61 BTCORDER 01h BTOSEIZURE ; Seizure trunk for outgoing call 02h BTODETEPTS ; Detect 'proceed to send' signal 03h BTOSTDEPTS ; Stop detect 'proceed to send' signal 04h BTOPARKING ; Put trunk in parking condition 05h BTOSPEECH ; Put trunk in speech condition 06h BTORELEASE ; Send release to PE 07h BTOFWEOS ; Forward EOS (register signalling ready) 09h BTOINQUIRY ; Initiate inquiry in PE 0Ah BTOSEOSFREE ; Send EOS signal, extension free 0Bh BTOSEOSBUSY ; Send EOS signal, extension busy 0Ch BTOBLOCK ; Block individual trunk 0Dh BTODEBLOCK ; Deblock individual trunk 0Eh BTOSENDPTS ; Send 'proceed to send' signal 0Fh BTOSEOS ; Send EOS signal 10h BTOSENDPES ; Send (periodic) end signal 11h BTOSENDSEIZ ; Send seize signal to PE 12h BTOSENDREL ; Send release signal to to PE 13h BTODETESPTS ; Detect special proceed-to-send signal 20h BTOSEIZACK ; Seizure accepted 21h BTOSEIZNAK ; Seizure rejected 22h BTOLOOP ; Loop back line on net side #SUBCODE:62 BTCPAR 00h BTPAN1 ; Parameters for analogue trunk 01h BTPAN2 ; Additional -''- 02h BTPCASI ; Parameters for CAS trunks 03h BTPCASC ; Parameters for CAS link 04h BTPISDNPC ; Parameters for ISDN-trunk 05h BTPSBAC ; Parameters for ISDN BA, S-interface 06h BTPISDNPCI ; Parameters for ISDN PRA/BTA 07h BTPSBACI ; Parameters for ISDN BA 08h BTPISDNINFCI ; Information for ISDN PRA/BTA 09h BTPMCINFO ; Packet mode comm. link param. for BA (T-, S-) 0Ah BTPACK ; Parameters are accepted 0Bh BTPNAK ; Parameters are rejected 20h BTPAN1READ ; Read parameters from analogue trunk 21h BTPAN2READ ; Read additional parameters -''- 22h BTPCASIREAD ; Read parameters from CAS trunk 23h BTPCASCREAD ; Read parameters from CAS link 24h BTPISDNPCREAD ; Read parameters from PRA/BRA T-interface 25h BTPSBACREAD ; Read parameters from ISDN BA S-interface #SUBCODE:64 BTCSIGNAL 01h BTSDETEPTS ; 'Proceed to send' detected 03h BTSBANSWER ; B-answer 04h BTSLINEOK ; Trunk line OK 05h BTSLINFAUL ; Trunk line faulty 06h BTSEOS ; 'End of selection' detected 07h BTSDIGIT ; Digit received 08h BTSINCCALL ; Incoming call 09h BTSINCDID ; Indialling call 0Ah BTSINCIOP ; Incoming call with internat. operator 0Bh BTSINCRING ; Incoming call with external ring signal 0Ch BTSDETEPES ; Periodic end signal detected 0Dh BTSINQUIRY ; Inquiry signal detected 0Eh BTSDISCONN ; Disc. or time out at incoming ring 0Fh BTSFREE ; Trunk is free 10h BTSPAGING ; Paging in progress 11h BTSPAGABS ; Paging equipment absent 12h BTSBLOCKED ; Trunk line blocked 13h BTSDEBLOCK ; Trunk line deblocked 14h BTSEOSFREE ; EOS detected, subscriber free 15h BTSEOSBUSY ; EOS detected, subscriber busy #SUBCODE:AF BTLSUP 0 BTLERRP1 ; Alarm, prio 1 1 BTLERRP2 ; Alarm, prio 2 2 BTLSLIP ; Slip detected 3 BTLNAT ; Alarms international/nationa bits 4 BTLDISC ; Order to TR, disconnect outgoing calls 5 BTLBLOCK ; Order to TR, block trunk for outg. traf. 6 BTLNOERR ; No error (disable blocking) 7 BTLSYNCEN ; Enable sync. of system (from trunk) 8 BTLSYNCDIS ; Disable syncronisation of system 9 BTLSCENACK ; Acknowledge of synk. enable 10 BTLSCDISACK ; Acknowledge of synk. disable 11 BTLINKBLOCK ; Order to block link for traffic 12 BTLINKDEBLOCK ; Order to deblock link for traffic 13 BTLL2ERR ; Alarm cond...layer 2 on ISDN-trunk 14 BTLTEI ; TEI assignment for the specific ISDN link Bit positions for ALARM in BTLERRP1 0 BTLLOSBIT ; LOS, loss of signal 1 BTLAISBIT ; ALS, alarm indication signal 2 BTLLFABIT ; LFA, loss of frame sync 3 BTLEBRBIT ; EBR, excessive biterror rate Bit positions for ALARM in BTLERRP2 0 BTLRAIBIT ; RAI, remote alarm indication 1 BTLLMFBIT ; LMF, loss of multiframe sync 2 BTLLMFRBIT ; LMFR, remote loss of multiframe sync 3 BTLCCEIBIT ; CCEI, continuous CRC error information #SUBCODE:48 IMPCTRL 00h IMPSEND ; Start digit impulsing 01h IMPSTOP ; Stop digit impulsing 02h IMPRDY ; Digit impulsing ready #SUBCODE:66 MPCONANSW 0 MPCACK ; Acknowledge of MPCON 1 MPCNAK ; Unsuccessful connection #SUBCODE:A3 REGCTRL For register control 1 RGCSEIZ ; Seize register TR->RS 2 RGCREL ; Release register TR->RS->RSU 3 RGCCHANGE ; Change signalling TR->RS 4 RGCRELFR ; Force Release register sequence RS->TR 10h RGCSTART ; Start register signalling RS->RSU 11h RGCPCM ; Control pcm-channel TR->RS->RSU 12h RGCRDY ; Signaling terminated RS->TR 13h RGCCHGMFE ; Change MFE receiving RS->RSU 14h RGCTIMEOUT ; MFE timeout RS->TR 15h RGCINVSIG ; Invalid signal RS->TR 16h RGCACTIV ; Activate already seized register process TR->RS 80h RGCACK ; Acknowledgement RSU->RS->TR 81h RGCACKSEIZ ; Acknowledgement on seizure RS->TR 82h RGCACKREL ; Acknowledgement on release RS->TR 83h RGCACKCHANGE ; Acknowledgement on change RS->TR 84h RGCNAK ; Non-acknowledgement RSU->RS->TR 85h RGCQUEUE ; Seizure in queue RS->TR For register order 20h RGODIGIT ; Send digit/digits TR->RS 21h RGONXTDIG ; Request next digit TR->RS 22h RGOADDCMP ; Address complete TR->RS 23h RGOCONG ; Congestion. TR->RS 24h RGOBUSY ; Called party busy TR->RS 25h RGOUNALLO ; Unallocated number TR->RS 26h RGOFREE ; Called party free TR->RS 27h RGOSUBS ; Calling is subscriber TR->RS 28h RGOOPER ; Calling is operator TR->RS 29h RGOACAT ; Send A category TR->RS 2Ah RGOREJ ; Request rejected TR->RS 2Bh RGOADIG ; Send A-number digit TR->RS 2Ch RGOAEND ; End of A-number TR->RS 2Dh RGOSETUP ; Address complete, speech TR->RS 2Eh RGOREQANO ; Request of A-number TR->RS 2Fh RGOEXTDIV ; External diversion TR->RS 90h RGOFSTA ; First A-signal TR->RS 91h RGOLOCSPEECH ; Local call speech TR->RS 92h RGOLOCDATA ; Local call data TR->RS 93h RGOSEMIAUTO ; Semi automatic call TR->RS 94h RGOTOLLCALL ; Toll automatic call TR->RS 95h RGOTESTCALL ; Test call TR->RS 96h RGOLINEOUT ; Subscriber out of order TR->RS 97h RGOSUBREJ ; A-number restricted TR->RS 0A0h RGOPROB ; Provinc. norm. B-charge TR->RS 0A1h RGOPROL ; Provinc. norm. L-charge TR->RS 0A2h RGONATB ; National norm. B-charge TR->RS 0A3h RGONATL ; National norm. L-charge TR->RS 0A4h RGOINTB ; Internat. norm. B-charge TR->RS 0A5h RGOINTL ; Internat. norm. L-charge TR->RS 0A6h RGOSPECB ; Special service B-charge TR->RS 0A7h RGOSPECL ; Special service L-charge TR->RS 0A8h RGOREQCLL ; Call class request TR->RS 0A9h RGOREQALL ; Req. all digits of called TR->RS 0AAh RGOREQBC ; Req. 'BC' digit group TR->RS 0ABh RGOREQGRA ; Group A request TR->RS 0ACh RGOREQGRC ; Group C request TR->RS 30h RGOSENBEG ; Begin sending signal RS->RSU 31h RGOSENEND ; Stop sending signal RS->RSU 32h RGOSENPLS ; Send signal pulse RS->RSU For register signal 40h RGSDIGIT ; Received digit/digits RS->TR 41h RGSNXTDIG ; Next digit from TR RS->TR 42h RGSADDCMP ; Address complete RS->TR 43h RGSCONG ; Congestion RS->TR 44h RGSBUSY ; Called party busy RS->TR 45h RGSUNALLO ; Unallocated number RS->TR 46h RGSFREE ; Called party free RS->TR 47h RGSSUBS ; Calling is subscriber RS->TR 48h RGSOPER ; Calling is operator RS->TR 49h RGSACAT ; Send A category RS->TR 4Ah RGSREJ ; Request rejected RS->TR 4Bh RGSADIG ; Send A-number digit RS->TR 4Ch RGSAEND ; End of A-number RS->TR 4Dh RGSSETUP ; Address complete, speech RS->TR 4Eh RGSREQANO ; Request of A-number RS->TR 4Fh RGSEXTDIV ; External diversion RS->TR 0B0h RGSFSTBDIG ; Send first dig of B-number RS->TR 0B1h RGSLASTBX ; Send last but x digit RS->TR 0B2h RGSSUBSWP ; Calling is subscriber with priority RS->TR 0B3h RGSADDCMPKD ; Address complete, send KD RS->TR 0B4h RGSLOCSPEECH ; Local call speech (KD) RS->TR 0B5h RGSLOCDATA ; Local call data (KD) RS->TR 0B6h RGSSEMIAUTO ; Semi automatic call (KD) RS->TR 0B7h RGSTOLLCALL ; Toll automatic call (KD) RS->TR 0B8h RGSTESTCALL ; Test call (KD) RS->TR 0B9h RGSTESTREQ ; Test request RS->TR 0BAh RGSSUBREJ ; A-number restricted RS->TR 0BBh RGSLINEOUT ; Lineout RS->TR 0C0h RGSPROB ; Provinc. norm. B-charge RS->TR 0C1h RGSPROL ; rovinc. norm. L-charge RS->TR 0C2h RGSNATB ; National norm. B-charge RS->TR 0C3h RGSNATL ; National norm. L-charge RS->TR 0C4h RGSINTB ; Internat. norm. B-charge RS->TR 0C5h RGSINTL ; Internat. norm. L-charge RS->TR 0C6h RGSSPECB ; Special service B-charge RS->TR 0C7h RGSSPECL ; Special service L-charge RS->TR 0C8h RGSREQCLL ; Call class request RS->TR 0C9h RGSREQALL ; Req. all digits of called RS->TR 0CAh RGSREQBC ; Req. 'BC' digit group RS->TR 0CBh RGSREQGRA ; Group A request RS->TR 0CCh RGSREQGRC ; Group C request RS->TR 50h RGSSENRDY ; Pulse sent RSU->RS 51h RGSRECBEG ; Receiving signal begun RSU->RS 52h RGSRECEND ; Receiving signal ended RSU->RS 53h RGSRECDTMF ; Signal received RSU->RS 54h RGSTRLDTMF ; Signal translated RS->TR 55h RGSTRC ; TRC detected RSU->RS->TR 0 RSN_LACKCAP ; Lack of capacity 1 RSN_BUSY ; Individual is busy 2 RSN_RPDSP ; Error between RP and DSP 3 RSN_FUNCNOTIMP ; Function not implemented 4 RSN_TONEOUTRGE ; Tone level out of range 5 RSN_DIGOUTRGE ; Digit out of range 6 RSN_NOCHGMFE ; Error in change betw. det. of 1-&2 freq. Data for register type 1 REGT_DTMFCEPT ; CEPT DTMF-receiver 2 REGT_DTMFCEPTEW ; CEPT DTMF-receiver, early warning 3 REGT_DTMFETOE ; End-to-end DTMF-receiver 4 REGT_DTMFETOEEW ; End-to-end DTMF-receiver, early warning 5 REGT_MFCOUT ; MFC outgoing direction 6 REGT_MFCIN ; MFC incoming direction 7 REGT_TRC ; TRC receiving 8 REGT_MFCAS ; MFC Forward, high freq. group, sending. 9 REGT_MFCAR ; MFC Forward, high freq. group, rec. 10 REGT_MFCBS ; MFC Backward, low freq. group, sending. 11 REGT_MFCBR ; MFC Backward, low freq. group, rec. 12 REGT_MFE1S ; MFE Sending MFE1 13 REGT_MFE1IR ; MFE Receiving MFE1 information 14 REGT_MFE1VR ; MFE Receiving MFE1 verification 15 REGT_MFE2S ; MFE Sending MFE2 16 REGT_MFE2IR ; MFE Receiving MFE2 information 17 REGT_MFE2VR ; MFE Receiving MFE2 verification 20 REGT_MFE1OUT ; MFE1 Outgoing direction 21 REGT_MFE1IN ; MFE1 Incoming direction 22 REGT_MFE2OUT ; MFE2 Outgoing direction 23 REGT_MFE2IN ; MFE2 Incoming direction 24 REGT_DTMFCEPTVS ; CEPT DTMF-receiver for voice services 25 REGT_DTMFETOEVS ; End-to-end DTMF-receiver for voice services Data for MFC signalling scheme 0 REGS_MFCSTD ; Standard MFC CCITT R2 1 REGS_MFCSMP ; Simplified MFC CCITT R2 2 REGS_MFCFIN ; Finnish MFC CCITT R2 3 REGS_MFCNOR ; Norweigian MFC CCITT R2 4 REGS_MFCMEX ; Mexican MFC CCITT R2 5 REGS_MFCAUS ; Australian MFC CCITT R2 6 REGS_MFCBEL ; Belgian simplified MFC CCITT R2 7 REGS_MFCMAL ; Malaysian MFC CCITT R2 8 REGS_MFCBRA ; Brazilian MFC CCITT R2 9 REGS_MFCBLM ; Brazilian MFC LME 10 REGS_MFCCHI ; China MFC R2 11 REGS_MFCISR ; Israel MFC R2 0 REGS_DTMFSTD ; Standard DTMF 0 REGR_STD ; Standard TRC Data for DTMF-Signal (digits) 0 DTMF_0 ; digit 0 1 DTMF_1 ; digit 1 2 DTMF_2 ; digit 2 3 DTMF_3 ; digit 3 4 DTMF_4 ; digit 4 5 DTMF_5 ; digit 5 6 DTMF_6 ; digit 6 7 DTMF_7 ; digit 7 8 DTMF_8 ; digit 8 9 DTMF_9 ; digit 9 0Ah DTMF_STAR ; * 0Bh DTMF_SQU ; # 0Ch DTMF_A ; signal A 0Dh DTMF_B ; signal B 0Eh DTMF_C ; signal C 0Fh DTMF_D ; signal D #SUBCODE:6E TONEPAR 1 TSPKSCPAR ; DTMF parameters 2 TSPTONEFREQ ; Traffic tone frequencies 3 TSPTONECAD ; Traffic tone cadences 4 TSPELU ; Traffic tone cadences for ELU 5 TSPACK ; Tone parameter acknowledge 6 TSPNAK ; Tone parameter non ackn. 0 TS_DTMF12 ; 12 codes. 0-9, *, # 1 TS_DTMF16 ; 16 codes. 0-9, *, #, A-D 00h TSEGENERR ; General 10h TSEKNODTMF ; Illegal number of DTMF-signals 11h TSEKLEVEL ; Illegal level 20h TSEFRAGNO ; Illegal tone fragment number 21h TSEFLEVEL1 ; Illegal level 1 22h TSEFFREQ1 ; Illegal frequency 1 23h TSEFLEVEL2 ; Illegal level 2 24h TSEFFREQ2 ; Illegal frequency 2 30h TSECTONENO ; Illegal tone number 31h TSECNOELEM ; Illegal number of elements in tone 32h TSECREPET ; Repetition from illegal element 33h TSECFRAGI1 ; Illegal internal tone frag. in element 1 34h TSECFRAGI2 ; .... in 2 35h TSECFRAGI3 ; .... in 3 36h TSECFRAGI4 ; .... in 4 37h TSECFRAGE1 ; Illegal external tone frag. in element 1 38h TSECFRAGE2 ; .... in 2 39h TSECFRAGE3 ; .... in 3 3Ah TSECFRAGE4 ; .... in 4 #SUBCODE:6C TONECTRL 1 TSCTONESTART ; Start tone sending 2 TSCTONESTOP ; Stop tone sending 3 TSCTONERDY ; Tone sending stopped 4 TSCTONEERROR ; Illegal tone ordered 5 TSCKSCSTART ; Start digit sending 6 TSCKSCSTOP ; Stop digit sending 7 TSCKSCRDY ; Digit sending stopped 8 TSCKSCERROR ; Tllegal DTMF ordered 9 TSCSXREQUEST ; Request of tone individual 10 TSCSXSTART ; Start/restart tonesending 11 TSCSXRELEASE ; Release of tone individual 12 TSCSXACK ; Okay 13 TSCSXNAK ; Not okay #SUBCODE:A2 STATEREP 'a' SRINFO ; Information state for extensions #SUBCODE:A0 TRANSM 02h TRMCONREQ ; Transmission connection request 03h TRMCONSPK ; Transmission speech connection 04h TRMCONNOM ; Transmission nominal (no speech) 05h TRMCONADJ ; Transmission adjusted (no speech) 0Ah TRMREP ; Transmission report 0Bh TRMREP2 ; Transmission report 2 connected channels 12h TRMCON ; Transmission connect 13h TRMADJ ; Transmission connect, adjusted levels 14h TRMNOM ; Transmission connect 21h TRMACK ; Transmission levels okay 22h TRMNAK ; Transmission levels not okay 25h TRMWARNING ; Warning in SX #SUBCODE:42 SYSPAR 00 SYPPCMCLAW ; PCM-coding princip 01 SYPNETW ; Networking date #SUBCODE:88 VOICEPAGCTRL 00 VPINIT ; Voice paging init 01 VPDATA ; Group data 02 VPTERM ; Terminate voicepaging #SUBCODE:52 MEMEX 0 RPM_NAK ; Subcode not implemented 1 RPMREAD ; Read in RP memory 2 RPMREAD_ACK ; Answer on RPMREAD 3 RPMREAD_NAK ; Answer on RPMREAD 4 RPMWRITE ; Write in RP memory 5 RPMWRITE_ACK ; Answer on RPMREAD 6 RPMWRITE_NAK ; Answer on RPMREAD 0 ONE_BYTE ; 1 byte (8 bits) 1 EIGHT_BYTES ; 8 bytes 2 ONE_WORD ; 1 word (16 bits) 3 FOUR_WORDS ; 4 word 4 ONE_LWORD ; 1 long word (32 bits) 5 TWO_LWORDS ; 2 long words 0 RPMW_VERIFIED ; written and verified 1 RPMW_UNVER ; written but not verified 2 RPMW_ERROR ; Error when verifying 0 RPMW_UNSPEC ; Unspec. error 1 RPMW_FORMAT ; Illegal format 2 RPMW_ILLEGAL ; Illegal address. 3 RPMW_NOT_ALL ; Not allowed to write 0 RPMR_UNSPEC ; Unspec. error 1 RPMR_FORMAT ; Illegal format 2 RPMR_ILLEGAL ; Illegal address. 3 RPMR_NOT_ALL ; Not allowed to read #SUBCODE:51 #SUBCODE:56 RPJOB RPJOBANSW 01h RPJCSUM ; Compute PROM checksum 01h RPJACSUM ; 81h RPJACSUM_ERR ; 02h RPJLED ; Control LEDs on board front 02h RPJALED ; 82h RPJALED_ERR ; 03h RPJBREV ; Asks for board revision 03h RPJABREV ; 83h RPJABREV_ERR ; 05h RPJPRNO1 ; Asks for product number of PROM1 04h RPJAPRNO1S ; 05h RPJAPRNO1P ; 85h RPJAPRNO1_ERR ; 07h RPJPRNO2 ; Asks for product number of PROM2 06h RPJAPRNO2S ; 07h RPJAPRNO2P ; 87h RPJAPRNO2_ERR ; 09h RPJPRNO3 ; Asks for product number of PROM3 08h RPJAPRNO3S ; 09h RPJAPRNO3P ; 89h RPJAPRNO3_ERR ; 0Ah RPJCADR ; Asks for card address (from port) 0Ah RPJACADR ; 8Ah RPJACADR_ERR ; 0Bh RPJTRACE ; To control the trace function 0Bh RPJATRACE ; 8Bh RPJATRACE_ERR ; 0Eh RPJCROF ; Asks for product number of card (ROF...) 0Dh RPJACROFS ; 0Eh RPJACROFP ; 8Eh RPJAROF_ERR ; 0Fh RPJPERTEST ; Asks for periodic test 0Fh RPJAPERTEST ; 8Fh RPJAPERTEST_ERR ; #SUBCODE:53 ADFUNCTION 01h ADCLEAR ; CP->RP Set max/min to current val. 02h ADSET_THRESHLD ; CP->RP Set thresholds for warnings 03h ADREAD_THRESHLD ; CP->RP Read thresholds for warnings 10h ADREAD_FAC_CUR ; CP->RP Read current values 11h ADREAD_FAC_MAX ; CP->RP Read maximum values 12h ADREAD_FAC_MIN ; CP->RP Read minimum values 13h ADREAD_SUP_CUR ; CP->RP Read current values 14h ADREAD_SUP_MAX ; CP->RP Read maximum values 15h ADREAD_SUP_MIN ; CP->RP Read minimum values 80h ADANSW_NAK ; RP->CP Function not available 81h ADANSW_ACK ; RP->CP Requested function done. 82h ADLIM_FAC_CUR ; RP->CP Out of limits message 83h ADANSW_THRESHLD ; RP->CP Answer upon ADREAD_THRESHLD 90h ADANSW_FAC_CUR ; RP->CP Answer with current values 91h ADANSW_FAC_MAX ; RP->CP Answer with maximum values 92h ADANSW_FAC_MIN ; RP->CP Answer with minimum values 93h ADANSW_SUP_CUR ; RP->CP Answer with current values 94h ADANSW_SUP_MAX ; RP->CP Answer with maximum values 95h ADANSW_SUP_MIN ; RP->CP Answer with minimum values 01h SUP_5V ; Addresses supervision probe for + 5V. 02h SUP_M48V ; Addresses supervision probe for - 48V. 03h SUP_M12V ; Addresses supervision probe for - 12V. 04h SUP_P12V ; Addresses supervision probe for + 12V. 05h SUP_M5V ; Addresses supervision probe for - 5V. 06h SUP_M8V ; Addresses supervision probe for - 8V. 07h SUP_P8V ; Addresses supervision probe for + 8V. 08h SUP_M40V ; Addresses supervision probe for - 40V. 09h SUP_TEMP ; Addresses supervision probe for internal 0Ah FAC_TEMP1 ; Addresses facilty temperature probe 1 0Bh FAC_TEMP2 ; Addresses facilty temperature probe 2 0Ch FAC_TEMP3 ; Addresses facilty temperature probe 3 #SUBCODE:60 CPICKUPCTRL 00h CPICKUPQ ; Call pickup question 01h CPICKUPACK ; Pick up possible 02h CPICKUPNAK ; Pick up not possible #SUBCODE:95 ELSTATE 0 ELSLINEBLOCK ; 1 ELSLINEOPEN ; #SUBCODE:54 TESTTRACE 61h CARDSIM ; Message to simulated card 62h CARDTEST ; Message from tested card 63h CPTEST ; Message from tested CP-unit 64h CPSIM ; Message to simulated CP-unit 65h MSGLOG ; Logged message 66h MSGLOGMPD ; Logged message, extended for MPD 67h MSGLOGREF ; Logged message, sendeer references #SUBCODE:46 TEXTEDIT 01h TEXTINIT ; Init of editing 02h TEXTANSW ; Text completed 03h TEXTTO ; Timeout editing 04h TEXTSTOP ; Stop session 05h TEXTNAK ; TEXTINIT rejected 06h TEXTREQ ; Fetch edited text 07h TEXTREQANSW ; Text request answer. #SUBCODE:94 ELDTRANSIT 0A9h ELT_IOSETUP ; External relay control 090h ELT_CLEARLED ; Clear a telephone led 091h ELT_SETLED ; Turn on a LED 0A2h ELT_PESREQ ; Request from Personal Efficiency System 0A3h ELT_PESGLOBAL ; Broadcast info for PES 0A4h ELT_PESINFO ; Information for PES 0A5h ELT_PCOPIREQ ; Request from PC operator 0A6h ELT_PCOPIINFO ; Information for PC operator 00h ETP_PROTREVQ ; PES protcol revision 01h ETP_DIVINFQ ; Diversion information 02h ETP_KEYDATAQ ; Instrument key programming 03h ETP_ACDGRPPAQ ; ACD group parameter 04h ETP_ACDGRPQ ; Login / logout ACD groups 05h ETP_ACDAGSTAT ; Activate / Deactivate ACD agent 06h ETP_ACDCCODE ; Call code 07h ETP_ACDALLAGSQ ; Status information of all ACD agents 08h ETP_ACDCLERTIMQ ; Clerical time of ACD-groups 09h ETP_ACDCOMPAQ ; Common ACD parameter 0Ah ETP_KEYCODE ; Request for keycode 0Bh ETP_DIVUPD ; Request diversion update 0Ch ETP_ACTINFTXT ; Activate information text 0Dh ETP_SENDMSG ; Send message 00h ETP_PROTREV ; PES protocol revision 01h ETP_CALLSTAT ; Call state to external connected equipement 02h ETP_NEWNUM ; New number information 03h ETP_CLIP ; Calling line identification (CLIP) 04h ETP_COLP ; Connected line identification (COLP) 05h ETP_DIVINFO ; Call diversion information 06h ETP_NAME ; Name of participated party 07h ETP_MAIL ; Change in mail box 08h ETP_KEYDATA ; Instrument key programming layout 09h ETP_ACDCALL ; An incoming call is indicated 0Ah ETP_ACDGRPACK ; Acknowledge to Login/logout ACD groups 0Bh ETP_ACDGRPNAK ; Not acknowledge to Login/logout ACD groups 0Ch ETP_ACDAGSACK ; Acknowledge to Activate/Deact. ACD agent 0Dh ETP_ACDAGSNAK ; Not acknowledge to Activate/Deact. ACD agent 0Eh ETP_ACDCCACK ; Acknowledge to Call-code 0Fh ETP_ACDCCNAK ; Not acknowledge to Call-code 10h ETP_ACDALLAGST ; Status info of all ACD agents 11h ETP_ACDNONACDCC ; Request for non-ACD callcode 00h ETPO_KEYCHRRSP ; Keypad character 01h ETPO_KEYCHRUPD ; Update keypad character 02h ETPO_SYSPRGACT ; Entering system programming 03h ETPO_SYSPRGREL ; Leaving system programming 00h ETPO_KEYCHRREQ ; Keypad character 01h ETPO_OPSTART ; Start operation 02h ETPO_OPEXIT ; Stop operation #SUBCODE:B0 COST 00h COSTPULSEQ ; Question of cost of pulses 01h COSTPULSEACK ; Positive answer with cost 02h COSTPULSENAK ; Negative answer 03h COSTTIMEQ ; Question of cost of duration 04h COSTTIMEACK ; Positive answer with cost 05h COSTTIMENAK ; Negative answer 06h COSTPREDFSTQ ; Question for first carrier 07h COSTPREDNXTQ ; Question for next carrier 08h COSTPREDACK ; Positive answer 09h COSTPREDNAK ; Negative answer 0Ah COSTPREDEND ; No more carriers 0Bh COSTMULTQ ; Question to multiple costs 0Ch COSTMULTACK ; Positive answer, including manipulated costs 0Dh COSTMULTNAK ; Negative answer 250 NA.UNDEF ; Destination group is not defined 00 COST.ILLCARR ; Illegal carrier number 01 COST.ILLTEN ; Illegal tennant number 02 COST.UNDDNG ; Undefined destination number group 03 COST.MISSDAT ; Data needed was not programmed 04 COST.GENERAL ; Unspecified type of fault 05 COST.ILLTARIFF ; Illegal tariff number #SUBCODE:25 SAVENO 0 SAVE.LNR ; Digits for last dialled number 1 SAVE.SNR ; Digits for last saved number #SUBCODE:B2 SERVICE 0 SENAK ; Requested service is not implemented 1 SEMCIDREQ ; MCID request 2 SEMCIDACK ; MCID accepted 3 SEMCIDNAK ; MCID rejected 4 SEMLTREQ ; ISDN call waiting request 5 SEMLTACK ; ISDN call waiting request : accepted 6 SEMLTNAK ; ISDN call waiting request : rejected 1 SERV.UNDEF ; Undefined reason 2 SERV.NOSUB ; Service not subscribed 3 SERV.UNAVAIL ; Service unavailable 4 SERV.INVSTAT ; Invalid call state in network 5 SERV.INVCALL ; Invalid call 6 SERV.NOINTACT ; Interaction not allowed #SUBCODE:B3 SISIG 1 SISEIZ ; Outgoing ISDN call to the network. 2 SISETUP ; Incoming ISDN call from the network. 3 SISETUPCOMP ; Incoming manual ISDN call 4 SIPTS ; SETUP accepted in ASB. 5 SISETUPACK ; SETUP accepted in the network. 6 SIPROGRESS ; Progress informat. from the network. 7 SIEOS ; End of selection in ASB. 8 SIPROCEED ; End of selection from the network. 9 SIRING ; Ringing started in ASB. 10 SIALERT ; Ringing started in the network. 11 SISPEECH ; Answer (speech) in ASB. 12 SIBANSWER ; Answer (speech) from the network 13 SIRELEASE ; Disconnection in ASB. 14 SIDISC ; Disconnection from the network. 15 SIDIGIT ; Digit(s) to/from the network. 16 SISEIZACK ; Seizure of trunk accepted. 17 SISEIZNAK ; Seizure of trunk rejected. 18 SIFREE ; Ind. trunk is free (after release). 30 SIUUISEIZ ; RP Outgoing proprietary CN call 31 SIADDUUISEIZ ; RP Additional SEIZ message for proprietary CN call 32 SIUUISETUP ; RP Incoming proprietary CN call 33 SIADDUUISETUP ; RP Addidional SETUP message for proprietary CN call 34 SIUUIRING ; RP Ringing started - proprietary CN call 35 SIADDUUIRING ; RP Additional proprietary information 36 SIUUIALERT ; RP Call is in ringing state - proprietary CN call 37 SIADDUUIALERT ; RP Additional proprietary information 38 SIUUISPEECH ; RP Answer (speech) - proprietary CN call 39 SIUUIBANSWER ; RP Speech from the line - proprietary CN call 40 SIUUIOUT ; RP User-to-user information to net 41 SIADDUUIOUT ; RP User-to-user information to net 42 SIUUIIN ; RP User-to-user information from net 43 SIADDUUIIN ; RP User-to-user information from net 44 SIUUIRELEASE ; RP Disconnection/release - proprietary CN call 45 SIUUIDISC ; RP Disconnection from the line - proprietary CN ; call 46 SIUUISERVICE ; RP Information concerning special services 47 SICNSEIZ ; RP Outgoing non-proprietary CN call 48 SICNSETUP ; RP Incoming non-proprietary CN call 49 SICNRING ; RP Ringing started - non-proprietary CN call 50 SICNALERT ; RO Call is in ringing state - non-proprietary CN ; call 51 SICNSPEECH ; RP Answer (speech) - non-proprietary CN call 52 SICNBANSWER ; RP Answer (speech) from the line - non-proprietary ; CN call 53 SICNRELEASE ; RP Disconnection/release - non-proprietary CN call 54 SICNDISC ; RP Disconnection from the line - non-proprietary CN ; call 60 SIFACILITY ; RP Additional information 69 SIFDATA ; RP Forward information data 70 SIFDATAEND ; RP Forward information data ended 71 SIBDATA ; RP Backward information data 72 SIBDATAEND ; RP Backward information data ended 112 SIRGSDIGIT ; RP BTUB/IP has received a DTMF message from the ; IP network including digit information 133 SIVIRSETUPACK ; RP SETUP accepted in the line (virtual call) 134 SIVIRPROGRESS ; RP Progress info to0/from the line (virtual call) 135 SIVIREOS ; RP End of selection for virtual calls 136 SIVIRPROCEED ; RP End of selection from line for virtual calls 142 SIVIRDISC ; RP Disconnection from the line - virtual call 144 SIVIRSEIZACK ; RP Seizure of trunk accepted - virtual call 145 SIVIRSEIZNAK ; RP Seizure of trunk rejected - virtual call 146 SIVIRFREE ; RP Ind. trunk is free after release of virtual ; call 158 SIVIRUUISEIZ ; RP Outgoing virtual call 159 SIVIRADDSEIZ ; RP Additional SEIZ message for virtual call 160 SIVIRUUISETUP ; RP Incoming virtual call 161 SIVIRADDSETUP ; RP Additional SETUP-message for virtual call 167 SIVIRUUIBANSWER ; RP Speech from line - virtual call 170 SIVIRUUIIN ; RP User-to-user information to net - virtual call 171 SIVIRADDUUIIN ; RP Additional user-to-user info. to net - ; virtual call 172 SIVIRUUIRELEASE ; RP Disconnection/release - virtual calls 173 SIVIRUUIDISC ; RP Disconnection from the line - virtual call 174 SIVIRSERVICE ; RP Information concerning special services 176 SIVIRCNSETUP ; RP Incoming non-proprietary virtual CN call 180 SIVIRCNBANSWER ; RP Answer (speech) from the line - ; non-proprietary CN call 181 SIVIRCNRELEASE ; RP Disconnection from line - ; non-proprietary virtual CN call 182 SIVIRCNDISC ; RP Disconnection/release - ; non-proprietary virtual CN call 1 SIDISC.MCID ; RP MCID facility available in the network 2 SIDISC.INBAND ; RP Inband information available in the network 3 SIDISC.MCINBND ; RP Inband info and MCID facility are avail... 4 SIDISC.NORMAL ; RP Network information available in the network 5 SIDISC.COMPL ; RP Disconnection complete, no more info... 6 SIDISC.CNAOC ; RP Get final charge information ; TON for public numbering plan (E.164) 00h NUM.UNKN ; Unknown number 01h NUM.INT ; International number 02h NUM.NAT ; National number 03h NUM.NET ; Network specific number 04h NUM.SUB ; Subscriber number ; TON for private no. plan (PRIVATE) 10h NUM.CMUNKN ; Unknown number 11h NUM.RL2 ; Regional number level2 12h NUM.RL1 ; Regional number level1 13h NUM.CNNET ; Network specific number 14h NUM.RL0 ; Local number ; TON for private no. plan (UNKNOWN) 20h NUM.NPUNKN ; Unknown NP & TON FFh NUM.UNDEF ; No number defined #SUBCODE:B4 CONPTYNUM 1 CONPTYREQ ; RP Request of number 2 CONPTYACK ; RP accepted 3 CONPTYNAK ; RP rejected 4 CONPIDACK ; Calling or connected (answering) number and name ; information 5 CONPIDDIV ; Calling or connected (answering) number and name ; information, diverting number and name information 6 CONPTFRREQ ; Request for 'new' calling/connected identity after ; call transfer 7 CONPIDTFR ; Sending of 'new' calling/connected number and name ; after call transfer 8 CONPIDRER ; Calling or connected (answering) number and name ; information, rerouting number and name information 2 CONP.RESTR ; RP Restricted 4 CONP.UNAVAL ; RP Unavailable #SUBCODE:32 CATREAD 0 CRR_ABBCOS ; Request to read ABBCOS 1 CRA_ABBCOS ; Answer of ABBCOS #SUBCODE:68 LCRNUM 0 LCRNUMQ ; Request number rearranging 1 LCRNANSW ; Answer incl. rearr. number 2 LCRNINFO ; Send rearranged number to trunk 0 LCRN_BNUM ; 1 LCRN_ACCESS ; 2 LCRN_AUTHORITY ; 3 LCRN_ACCOUNT ; 4 LCRN_OWNDIRNO ; 5 LCRN_DTMF ; 6 LCRN_TONE ; 7 LCRN_DELAY ; 8 LCRN_ERROR ; 00 LCRNUM.ILLCARR ; undefined carrier number 01 LCRNUM.ILLTEN ; undefined tenant number 02 LCRNUM.MISSDAT ; no programmed data 03 LCRNUM.GENERAL ; general failure #SUBCODE:69 NUMCONVERT 0 NCREQ ; Request a conversion 1 NCACK ; Positive answer 2 NCNAK ; Negative answer 0 NC.NOORIGTAB ; no original number table exists 1 NC.NONEWTAB ; no new number table exists 2 NC.NOORIGNUM ; no original destination number exists 3 NC.NONEWNUM ; no new destination number exists #SUBCODE:23 AUTHCODE 0 AUTHQRY ; Request to verify authority code 1 AUTHACK ; Positive acknowledge 2 AUTHNAK ; Negative acknowledge 3 MAILACC ; Verify access to common-mailbox 4 MAILACCACK ; Positive acknowledge 5 MAILACCNAK ; Negative acknowledge 6 AUTHCHG ; Request to change authority code 7 AUTHCHGACK ; Positive acknowledge 8 AUTHCHGNAK ; Negative acknowledge #SUBCODE:30 INDDATAANSW 0 PWCHKBIT ; Access for internal retrieving of voice #SUBCODE:85 GUEST 0 LANGQRY ; Request language for guest 1 LANGANSW ; language answer #SUBCODE:33 DIRCTRL 1 DELSER ; Delete a common short number series 2 CRESER ; Create a common short number series #SUBCODE:36 CTIFUNC 00h MONVERRQ ; Query a monitor on an extension 01h MONVERRSP ; Positive acknowledge for query 02h MONSTRTRQ ; Start a monitor on an extension 03h MONSTRTRSP ; Response for start request 04h MONSTRTACD ; ACD response for start 05h MONSTOPRQ ; Stop a monitor on an extension 06h MONSTOPRSP ; Response for stop request 07h MONSTOPACD ; ACD response for stop request 08h MONEND ; Report a monitor end on an extension 09h MONSUPPORT ; Report if monitoring is supported at all 10h ROUTETIMEOUT ; Waiting timeout value for reroute dest. 11h CTKEYCODE ; Keycode message from CT-block 20h EVSTATUPD ; Report device state update event 21h EVDIRNUMCH ; Report directory number change 23h EVNAMEUPD ; Report opposite / divertee name 24h EVFORWARDUPD ; Report update of call forwarding 25h EVACDUPD ; Report update of ACD-status 26h EVFEATURE ; Report activated features 27h EVREPCALLREC ; Report call record 28h EVSLAVEUPD ; Report slave state update event 29h EVOPIDATA ; Report special OPI data 2Ah EVOPIQUE ; Report status of OP queue 2Bh EVINFOUPD ; Report update of Info status 2Ch EVFACUPD ; Report update of facility status 2Dh EVACDQUPD ; Report ACD queuestate update 70h REQMAKECALL ; Request to start a fresh call 71h RSPMAKECALL ; Response to a requested make call 72h REQFWDSTAT ; Request to report call forwarding info 73h REQACDSTAT ; Request to report ACD agent status 74h REQCONFCALL ; Request to start a conference 75h RSPCONFCALL ; Response to a requested conference 76h REQFWME ; Request a Follow Me on extension 77h REQPICKUPIND ; Request to do individual pickup 78h RSPPICKUPIND ; Response to a requested individual pickup 79h REQINFO ; Request an info on extension 7Ah REQMESS ; Request a message on extension 7Bh REQDND ; Request Do not desturb 7Ch RSPDND ; Response to a requested Do not desturb 7Dh REQPCROUT ; Request reporting of incoming calls 7Eh RSPPCROUT ; Response to a request PC controlled routing 7Fh REQNEWDEST ; Request reroute to new destination 80h RSPNEWDEST ; Response to a request new destination 81h REQTRANSFER ; Request transfer of a call 82h RSPTRANSFER ; Response to a requested transfer 83h REQFORWARD ; Request to initiate call forward 84h RSPFORWARD ; Response to a requested call forward 85h REQANSWER ; Request to answer a call 86h REQCAMPON ; Request to do a camp on 87h REQPICKUPGRP ; Request to pickup call from group 88h RSPPICKUPGRP ; Response to a request group pickup 89h REQSNAPDEV ; Request snapshot device 8Ah RSPSNAPDEV ; Response to a request snapshot device 8Bh REQCB ; Request to initiate call back 8Ch REQBI ; Request to initiate break in 8Dh REQHOLD ; Request to put a call on hold 8Eh REQSNAPACD ; Request snapshot ACD 8Fh RSPSNAPACD ; Response snapshot ACD 90h REQDEFLECTCALL ; Request deflection of an incoming call 91h RSPDEFLECTCALL ; Response deflection of an incoming call 92h REQINFOSTAT ; Request Info states/Info texts 93h RSPINFOTXT ; Response Info texts 94h REQVOICEPG ; Request a voipe paging action 95h RSPVOICEPG ; Response to voice page command 96h REQKEYLAYOUT ; Request instrument key programming layout 97h RSPKEYLAYOUT ; Response instrument key programming layout 98h REQOPIFUNC ; Request special function of operator instr. 99h REQSETTINGS ; Request change of device settings 9Ah RSPSETTINGS ; Response to change of device settings 9Bh REQLINKPOS ; Request linking position 9Ch RSPLINKPOS ; Response linking position #SUBCODE:37 PESGLOBAL 01h PESACDQUELEN ; Present queue length of every ACD group 02h PESACDAGSTAT ; Status of an ACD agent monitored by ACD supervisor 03h PESACDGRPINFO ; Parameter of all ACD groups 04h PESACDCLERTIM ; Clerical time of all ACD-groups 05h PESACDCOMINFO ; Common ACD parameter #SUBCODE:2A TFRQ 00h TQB_ACDLOG ; Log order for transferred ACD-call #SUBCODE:B5 TISIG 1 TISEIZ ; RP Call to Cordless 2 TIRELEASE ; RP Disconnection in ASB 3 TICLIP ; RP Call update to cordless 4 TIMWI ; RP Turn on message waiting indication 5 TIIDLE ; RP Send idle display information 6 TIINCALL ; RP Send incall display information 7 TICONN ; RP Send connected information 8 TIREDIR ; RP Send redirected information 32 TIDISC ; RP Disconnection from the Cordless 33 TISEIZACK ; RP Seizure of Cordless accepted 34 TISEIZNAK ; RP Seizure of Cordless rejected 35 TIALERT ; RP Cordless has started ringing #SUBCODE:80 DISPLAYCTRL 1 DISPREQ 2 DISPREL #SUBCODE:5F TRSTATUS 01h TRIDLE ; Trunk status IDLE 02h TRBUSY ; Trunk status BUSY #SUBCODE:5E BLOCKINFO 01h BIOPTEMP ; Time and temperature value 02h BIPROTREQ ; Request info about protection level 03h BIPROTUPD ; Inform about change in protection level 04h BIRESCHKREQ ; Request for a resource check 05h BIRESCHKINIT ; Initiate a resource check 06h BIRESCHKRDY ; Resource check has been finished 07h BIKEYPADREQ ; Request of ASCII characters programmed ; on the dedicated digit key 08h BIKEYPADRSP ; Response of ASCII characters programmed ; on the dedicated digit key 09h BIKEYPADUPD ; ASCII characters programmed on the dedicated digit key ; during preprogramming 0Ah BIEXTMAIL ; Broadcasts external voice mail address to operator 0Bh BIDAYNIGHT ; Information about the status of the system day/night switch 00h PRTIDCTIV21 ; Version 2.1 functionality of CTI 01h PRTIDMONOP ; Monitorign of operator instrument + queue 02h PRTIDACCOUNTV24 ; Enhanced CIL functionality 03h PRTIDTANDEMCTI ; Tandem configuration with CTI 04h PRTIDNWQSIG ; Networking with QSIG 05h PRTIDNWFULL ; Full networking 06h PRTIDNWSMALL ; Small scale networking 07h PRTIDISDNCLIST ; ISDN caller list 08h PRTIDIAD ; Enhanced individual abbreviated dialling 09h PRTIDINFO ; Enhanced information system 0Ah PRTIDGAPPROT ; GAP protocol 0Bh PRTIDACDCCODES ; ACD multiple call codes 0Ch PRTIDSWAPBOARD ; Swapping of boards during operation 0Dh PRTIDUPGRADESW ; Remote upgrading of central software 0Eh PRTIDOMCORDL ; Cordless remote O&M 10h PRTIDUUIT ; UUI Italy 11h PRTIDCNNUMPLAN ; Adaption for CN numbering plan feature 12h PRTIDALTROUT ; Alternative routing on no line available 13h PRTIDNUMREST ; Override number restriction in ISDN (Austria) 14h PRTIDISDNPMP ; ISDN point to multipoint 15h PRTIDMULTINC ; Multiple incoming call presentation 16h PRTIDDDITRANS ; ECE DDI number translation 17h PRTIDTARIFF ; Austrian call metering tariff 18h PRTIDPGREET ; VMU-HD individual greeting 19h PRTIDMOHIND ; Integrated MOH 1Ah PRTIDFNENH ; Fictive numbers extended/improved 1Bh PRTIDCOPACT ; CN/operator services active 1Ch PRTIDCTIGRP816 ; CTI groups 8/16 1Dh PRTIDNW4 ; Very small networking (4 interfaces) 1Eh PRTIDX25X31 ; X.25 protocol and X.31 services (packet mode terminals) 1Fh PRTIDUUIGPF ; UUS in MSI of GPF 20h PRTIDCONVREC ; Conversation recording 21h PRTIDIED ; Diversion individual to external destination 22h PRTIDGAP20 ; Integrated Cordless - GAP 2.0 protocol 23h PRTIDMULTMOH ; Music on hold (1 integrated and 7 external sources or 8 external sources) 24h PRTIDUPGRADEFW ; O&M - Remote FW upgrading 25h PRTIDNW2 ; Very small networking (2 interfaces) 26h PRTIDSUMTIMISDN ; Automatic summer / winter time change from ISDN 27h PRTIDACCCODEVFY ; Verified Account Codes 28h PRTID3PARTYCONF ; 3-Party conference on ISDN 29h PRTIDPARTREROUT ; Call forwarding with partial re-routing 2Ah PRTIDCENTREX ; Centrex Hook Flash over ISDN 2Bh PRTIDIID ; Individual Internal Diversion 2Ch PRTIDOUTCALL ; Outcall notification 2Dh PRTIDENHMOH ; Enhanced Integrated Music on Hold 2Eh PRTIDDDISTEP3 ; Number translation 2Fh PRTIDLEAVEACD ; Leave ACD queue via exit position #SUBCODE:5D CICTRL 00h CISTORE ; Store calling party number 01h CILIST ; Dirno amount of calling party numbers in list 02h CIACK ; Attempt to connect calling party number was answered 03h CINAK ; Attempt to connect calling party number was not answered #SUBCODE:5C MUCTRL 00h MUIDLECHN ; background music PCM channel 01h MUHOLDCHN ; music on hold PCM channel 02h MUACK ; answer msg for subcodes MUIDLECHN and MUHOLDCHN 03h MUNAK ; answer msg for subcodes MUIDLECHN and MUHOLDCHN 04h MUANNOLOADED ; inform that announcements are loaded #SUBCODE:79 UPDIND 50h DELIND ; Delete individuals directory number 51h DELINDRDY ; Clearing of directory number ready 52h UPDROP ; Request for handover IP call #SUBCODE:96 PNRINFO 00h PNRI.REQ ; Request TON programmed for given PNR number 01h PNRI.ANSW ; Send TON programmed for given PNR number #SUBCODE:CF ALARMCTRL 00h ALARMACT ; Activate alarm for extension with incl. dirno #SUBCODE:84 GROUPCTRL 01h GRPC.SEIZ ; Group ringing request to a member of a PBX group 02h GRPC.ACK ; Receiver accepts request and invokes ringing 03h GRPC.NAK ; Receiver rejects request 04h GRPC.REL ; Group ringing released. Receiver returns to idle. 05h GRPC.QUERY ; Sender requests data of actual call 06h GRPC.DATA ; Response to GRPC.QUERY 07h GRPC.MEMBCHK ; Sender queries if member of a particular PBX group 08h GRPC.MEMBACK ; Member of desired PBX group 09h GRPC.MEMBNAK ; Not a member of desired PBX group 0Ah GRPC.GRPLOGIN ; All traffic from desired PBX group enabled 0Bh GRPC.GRPLOGOUT ; All traffic from desired PBX group disabled 0Ch GRPC.ALLLOGOUT ; All traffic from all PBX groups disabled 0Dh GRPC.ALLLOGIN ; All traffic from all PBX groups enabled #SUBCODE:D0 IPDATA 01h IPBASWR ; RP Write basic IP data record 02h IPRECWR ; RP Write extended IP data record (linked record) 03h IPWRACK ; RP Positive write acknowledgment 04h IPWRNAK ; RP Negative write acknowledgment 05h IPRDREQ ; RP Request for read of dynamic data 06h IPRDANSW ; RP Answer to read request for dynamic data 07h IPDATARDY ; RP Write IP data ready #SUBCODE:D1 UPGRAD 01h UPGRDREQ ;RP Upgrade start request 02h UPGRDREQREJ ;RP Upgrade request rejected 03h UPGRDSTART ;RP Upgrade start command 04h UPGRDCONT ;RP Upgrade procedure continues 05h UPGRDCOMPL ;RP Upgrade procedure successfully performed 11h UPMEMWR ;RP Upgrade memory write request 12h UPMEMCLEAR ;RP Upgrade memory storage clear request 13h UPMEMCLEARACK ;RP Upgrade memory clear acknoledgement 14h UPMEMCLEARNAK ;RP Upgrade memory clear error indication 15h UPMEMCHK ;RP Upgrade memory check request 16h UPMEMCHKACK ;RP Upgrade memory check acknoledgement 17h UPMEMCHKNAK ;RP Upgrade memory check error indication 13h UPMEMCHKNAK ;RP Upgrade memory check error indication #SUBCODE:D2 ACCTRL 00h ACACK ; Positive response - account code valid 01h ACNAK ; Negative response - account code iunvalid 02h ACCODE ; Check validity of account code